User manual FURUNO IF-2000 OPERATORS MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FURUNO IF-2000. We hope that this FURUNO IF-2000 user guide will be useful to you.

Lastmanuals help download the user guide FURUNO IF-2000.


Mode d'emploi FURUNO IF-2000
Download
Manual abstract: user guide FURUNO IF-2000OPERATORS MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] Only qualified personnel should work inside the equipment. Turn off the radar power switch before servicing the antenna unit. Post a warning sign near the switch indicating it should not be turned on while the antaean unit is being serviced. Prevent the potential risk of being struck by the rotating antenna and exposure to RF radiation hazard. [. . . ] For example, press the [4] key to select FUNC 1. 1. FUNC 1 FUNC SEL CST OCEAN R-SEA FLT BY HBR L RAIN ECHO AVG OFF 0. 5 1 2 3 INT REJ OFF 1 2 3 STRETCH OFF 1 2 N REJ OFF ON ENHANCE OFF ON CONTRAST 1 2 3 A/C AUTO OFF ON PULSE 1. FUNC 2 FUNC SEL CST OCEAN R-SEA FLT BY HBR L RAIN ECHO AVG OFF 0. 5 1 2 3 INT REJ OFF 1 2 3 STRETCH OFF 1 2 N REJ OFF ON ENHANCE OFF ON CONTRAST 1 2 3 A/C AUTO OFF ON PULSE 1. FUNC 3 FUNC SEL CST OCEAN R-SEA FLT BY HBR L RAIN ECHO AVG OFF 0. 5 1 2 3 INT REJ OFF 1 2 3 STRETCH OFF 1 2 N REJ OFF ON ENHANCE OFF ON CONTRAST 1 2 3 A/C AUTO OFF ON PULSE 3. 0. Above does not mean the optimum setting, but just for explanation. Press the [2] key several times to select function desired. The settings of items 3-9 automatically change according to selection made at step 4. Press the [MENU] key. -1. 32- 1. 34. 2 Activating/deactivating a function Press the [FUNCTION] key. Each time the key is pressed a preset function the preset functions enabled on the FUNC menu are turned on or off cyclically. You may enable/disable preset functions from the menu as follows: 1. Press the [MENU] key followed by the [6] key twice to display the FUNC menu. 0. ECHO SIG COLOR YEL GRN * CLTR SWEEP OFF ON (LINK) SWEEP LEVEL 123 ENHANCE OFF ON 2ND ECHO OFF ON PULSE 1 PULSE 2 A/D CURVE ABCD CNTR ENHANCE OFF ON REALTIME HU OFF ON * Color available on R-type. Press the [MENU] key followed by the [5] key twice to show the ECHO SIG menu. Press the [4] key to select OFF or ON from the ENHANCE field as appropriate. Press the [ENTER/SELECT] key, and then press the [MENU] key. Echo enlarged in bearing and range directions 1. 37 Watch Timer The watch timer works like an alarm clock, sounding visual WATCH and audible alarms at a predetermined interval. To silence the alarm, press the [AUDIO OFF] key. The label WATCH turns to normal color and the alarm timer is reset to the initial and starts the count-down sequence again. Press the [MENU] key followed by the [4] key twice to select WATCH TIME. WATCH TIME 1. ALM INTVL OFF 3min 6min 15min 20min 12min 2. Press the [1] key to select desired interval (3, 6, 12, 15, 20 min) from the ALM INTVL field. Press the [ENTER/SELECT] key to conclude your selection followed by the [MENU] key to close the menu. -1. 36- 1. 38 Noise Rejector The noise rejector suppresses white noise, which appears on the screen as many dots scattered randomly over the display. Press the [7] key to turn the noise rejector on or off as appropriate. [. . . ] The positioning system Mode indicator and Status fields shall not be null fields. -8. 5- HDG - Heading, deviation and variation IMO Resolution A. 382 (X). Heading (magnetic sensor reading), which if corrected for deviation, will produce magnetic heading, which if offset by variation will provide true heading. $--HDG, x. x, x. x, a, x. x, a*hh<CR><LF> Checksum Magnetic variation, degrees, E/W (see notes 2 and 3) Magnetic deviation, degrees, E/W (see notes 1 and 3) Magnetic sensor heading, degrees * Not used NOTES 1 To obtain magnetic heading:Add easterly deviation (E) to magnetic sensor reading Subtract westerly deviation (W) from magnetic sensor reading 2 To obtain true heading: Add easterly variation (E) to magnetic heading Subtract westerly variation (W) from magnetic heading 3 Variation and deviation fields will be null fields if unknown. HDT - Heading True $--HDT, x. x, T*hh<CR><LF> Checksum Heading, degree true * Not used MTW - Water temperature $--MTW, x. x, C*hh<CR><LF> Checksum Temperature, degrees C * Not used -8. 6- RMA - Recommended minimum specific LORAN-C data Position, course and speed data provided by a LORAN-C receiver. Time differences A and B are those used in computing latitude/longitude. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO IF-2000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FURUNO IF-2000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag