If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GAF EVERGUARD TPO LOW VOC BONDING ADHESIVE. We hope that this GAF EVERGUARD TPO LOW VOC BONDING ADHESIVE user guide will be useful to you.

Lastmanuals help download the user guide GAF EVERGUARD TPO LOW VOC BONDING ADHESIVE.


Mode d'emploi GAF EVERGUARD TPO LOW VOC BONDING ADHESIVE
Download
Manual abstract: user guide GAF EVERGUARD TPO LOW VOC BONDING ADHESIVEMATERIAL SAFETY DATASHEET UPDATED 01-2010

Detailed instructions for use are in the User's Guide.

[. . . ] Can cause gastrointestinal irritation, nausea and vomiting. Aspiration of material into lungs may cause chemical pneumonitis which can be fatal. High concentrations may cause acute central nervous system depression characterized by drowsiness, headaches, dizziness, nausea, paralysis, and loss of consciousness. High vapor concentrations may cause central nervous system (CNS) depression with symptoms including light headedness, giddiness, nausea, drowsiness, headache, nose, throat and respiratory tract irritation, reduced appetite, confusion and unconsciousness. [. . . ] Static charge may accumulate by flow or agitation. Grounding and bonding of containers is required. Page 3 of 8 GAF Materials Corporation SECTION 6: ACCIDENTAL RELEASE MEASURES ACCIDENTAL RELEASE MEASURES: MSDS # 2120 Eliminate all ignition sources (flames, hot surfaces and sources of electrical, static or frictional sparks). Dike and contain spill with inert material (e. g. Transfer liquids to covered metal containers for recovery or disposal, or remove with inert absorbent. Place absorbent diking materials in covered metal containers for disposal. Prevent contamination of sewers, streams and groundwater with spilled material or used absorbent. SECTION 7: HANDLING AND STORAGE HANDLING AND STORAGE: Keep container closed when not in use. Store at 60 ­ 80 °F and out of the sun and away from ignition sources. Use adequate ventilation to avoid breathing vapors when cover is removed. Ground and bond all equipment when handling flammable solvent borne materials. Shelf life is 1 year from manufacturers date in an unopened container. For professional or industrial use only. Turn off all pilot lights, flames, stoves, heaters, electric motors, welding equipment and other sources of ignition. Contact lens wearers take appropriate precautions. For spray applications, use only with approved spray equipment. For flammable products, vapors may cause flash fire or ignite explosively. To prevent buildup of vapors, use adequate ventilations (e. g. open all windows and doors to achieve crossventilation). Never use welding or cutting torch on or near container. Do not cut, drill, grind, or expose containers to heat, sparks, static electricity or other source of ignition. OTHER PRECAUTIONS: SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION ENGINEERING CONTROLS / VENTILATION: Provide sufficient explosion proof mechanical ventilation to prevent exceeding recommended exposure limits or build up of explosive concentrations of vapor in air. If personal exposure concentrations cannot be maintained below the appropriate exposure limits using engineering controls, a NIOSH/MSHA approved organic vapor air purifying respirator may be appropriate based on employer-determined exposure levels. [. . . ] State or local Page 6 of 8 GAF Materials Corporation MSDS # 2120 regulations may also apply if they differ from the federal regulation. RCRA HAZARD CLASS: D001, Ignitable Hazardous Waste SECTION 14: TRANSPORTATION INFORMATION U. S. DOT TRANSPORTATION PROPER SHIPPING NAME: HAZARD CLASS: ID NUMBER: PACKING GROUP: LABEL STATEMENT: OTHER: Adhesives, 3, UN1133, II 3 UN1133 II Flammable Liquid N/A SECTION 15: REGULATORY INFORMATION U. S. FEDERAL REGULATIONS TSCA: CERCLA: This product and its components are listed on the TSCA 8(b) inventory. CERCLA Hazardous Substances (40 CFR 302) Reportable Quantity ­ Components n-Hexane: 110-54-3, 5000 lbs Toluene: 108-88-3, 1000 lbs Cyclohexane: 110-82-7, 1000 lbs Methanol: 67-56-1, 5000 lbs SARA 311/312 HAZARD CATEGORIES: 313 REPORTABLE INGREDIENTS: Fire Hazard, Acute Health Hazard, Chronic Health Hazard Toluene 108-88-3, 10 ­ 30% N-Hexane 110-54-3, 3 ­ 10% Cyclohexane 110-82-7, 1 ­ 5% This product contains a chemical known to the state of California to cause cancer and birth defects, or other reproductive harm. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GAF EVERGUARD TPO LOW VOC BONDING ADHESIVE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GAF EVERGUARD TPO LOW VOC BONDING ADHESIVE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag