User manual GAF TOPCOAT TITANIUM FOR METAL SPECIFICATIONS REV 11-2002

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GAF TOPCOAT TITANIUM. We hope that this GAF TOPCOAT TITANIUM user guide will be useful to you.

Lastmanuals help download the user guide GAF TOPCOAT TITANIUM.


Mode d'emploi GAF TOPCOAT TITANIUM
Download
Manual abstract: user guide GAF TOPCOAT TITANIUMFOR METAL SPECIFICATIONS REV 11-2002

Detailed instructions for use are in the User's Guide.

[. . . ] Topcoat Titanium Metal Specifications PART 1 - GENERAL 1. 01 RELATED SECTIONS / DOCUMENTS 1. 05 REGULATORY REQUIREMENTS GAF Detail Drawings, site-specific drawings and General Provisions of the contract, including General, Supplementary and Special Conditions found in Division7 Specification Sections, apply to the work addressed in this section. FM Listing: Provide GAF Roofing System and component materials which have been evaluated by Factory Mutual System for flame-spread and are listed in "Factory Mutual Approval Guide" for Class I construction over existing metal roofing (Flame spread must be in accordance with ASTM #E-108). Provide roof covering materials, bearing FM approval marking on package or container, which indicates that material has been subjected to FM's examination, test procedures, follow-up inspection services and approval. UL Listing: Provide GAF Roofing System and component materials which have been evaluated by Underwriters Laboratories for flame-spread, and are listed in "Underwriters Laboratory Roofing Materials and Systems Directory" for Class A construction over existing metal or other non-combustible roofing (Flame-spread must pass ASTM #E-108 with unlimited slope). [. . . ] Do not proceed with installation of the GAF Roofing System until unsatisfactory conditions have been corrected in a manner acceptable to the manufacturer (GAFMC). Preparation of the Roof Substrate is the responsibility of the Installer. Installer shall address and correct all of the following: · · · · · · · · Treatment of excessive gaps Installation of sheet metal crickets Treatment of ponding water areas Repair of dented / damaged panels Re-tightening and replacement of fasteners Thorough cleaning / Removal of existing paints and coatings Treatment of residual asphalt Treatment of rust areas C. Treatment of Excessive Gaps: All large or excessive gaps existing between roof panels must be closed or made flush with EverTiteTM self-drilling fasteners. Closed-celled foam strips or polyurethane foam may be used to pre-fill voids larger than 1/4 inch before applying GAF Flashing Grade. Foam shall be shaped with a utility knife or other method to create a cant strip which facilitates both GAF adhesion and water drainage, as well as, prevents shearing of Topester Fabric on metal edges. Installation of Sheet Metal Crickets: (Required) Sheet metal crickets must be installed according to Manufacturer's specifications (minimum 26 gauge Metal - heavier gauge required for larger crickets) on the high side of all curb units. Vertical ribs shall be cut a minimum of 2" from the cricket to allow both the cricket flanges to mount flush to the metal panel and facilitate water drainage. Cut vertical ribs shall then be treated in the same fashion as a void larger than a 1/4 inch. New crickets shall be "sealed" by placing a continuous bead of GAF Flexseal under the flanges before they are mechanically attached to the curb unit and metal roof panel. The cricket flanges must then be stitch-screwed to the curb unit and metal roof panel while the Flexseal is still wet using EverTiteTM fasteners. This procedure shall apply to Topcoat Titanium Metal Specifications be required during the pressure washing to obtain proper adhesion for GAF products. When encountering roof substrates that have living organisms such as algae, mold or fungus, a bleach solution shall be used to kill / remove these organisms during the roof cleaning. Treatment of Residual Asphalt: Installer shall make every effort to remove asphaltic roofing elements. Removal efforts must include use of methods such as pressure-washing, scrapers, wire brushes, electrical drill wire-wheels, or other similar tools. Residual asphalt is defined as asphaltic material remaining after the exercise of all required removal efforts, and exists when there is asphaltic material greater in thickness than 3 mils over an area greater than 1 square foot. Residual asphaltic areas are to be treated with MB+. Apply GAF MB+ at a rate of 1 gal per sq. to the entire asphaltic area to be treated. Asphaltic area not to exceed 20% of the total roof area. Installation of a cap on the ridge vent will prevent water entry while allowing air to continue to flow through the vent. Inadequate roof ventilation may cause blistering in the GAF Roofing System due to inside air "blowing-out" through roof panel seams. When this condition occurs, it may not allow for proper curing of the Flashing Grade material which may cause blisters · Condensate Lines: GAFMC recommends installation of condensate lines from HVAC units to gutters as part of the overall roofing contract. [. . . ] Finish coat shall be applied parallel to the ribs of the roof panels. It should 3. 03 not be applied unless the intermidiate coat is clean and will provide proper adhesion. Allow a minimum of 24 hours drying time prior to allowing foot traffic or inspection of roof surface. After at Least 24 Hours Has Elapsed, inspect the final roof surface for flaws, holidays, insufficient thickness, etc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GAF TOPCOAT TITANIUM

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GAF TOPCOAT TITANIUM will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag