User manual GAGGENAU AI280720

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GAGGENAU AI280720. We hope that this GAGGENAU AI280720 user guide will be useful to you.

Lastmanuals help download the user guide GAGGENAU AI280720.


Mode d'emploi GAGGENAU AI280720
Download
Manual abstract: user guide GAGGENAU AI280720

Detailed instructions for use are in the User's Guide.

[. . . ] Gaggenau Operating and installation instruction Extractor hood AI 280720 Safety Instructions Read And Save These Instructions. WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. ) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. b. ) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. [. . . ] Do not use aggressive, acidic or caustic cleaners. Then brush the filters clean, rinse them thoroughly and leave the water to drain off. 10 Activated carbon filter For neutralizing odours in recirculating mode. Caution: As the filter becomes more and more saturated with grease, there is an increased risk of fire and the function of the extractor hood may be impaired. Important: Change the activated carbon filter promptly to prevent the risk of fire from the accumulation of heat when deep-fat frying or roasting. Installation and removal: IMPORTANT: The lighting must be switched OFF and cool. . 1 2 Remove the metal-mesh filters (see "Removing and inserting the metal-mesh grease filters"). Insert the activated carbon filter. 3 Insert the metal grease filters (see "Removing and inserting the metal grease filters"). Replacing the activated carbon filter: · · · · During normal operation (1 to 2 hours per day) the activated carbon filters should be replaced approximately 1 x year. A replacement filter can be obtained from any authorized dealer (see optional accessories). By doing so you will obtain maximum performance from your extractor hood. Disposing of the old activated carbon filter: There are no pollutants in the activated carbon filters. They can therefore be disposed of as part of your normal domestic refuse. 11 Cleaning and care Isolate the extractor hood by pulling out the mains plug or switching off the fuse. Do not clean the extractor hood with abrasive sponges or with cleaning agents which contain sand, soda, acid or chlorine!Stainless steel surfaces: · · · Use a mild non-abrasive stainless steel cleaner. Clean the surface in the same direction as it has been ground and polished. We recommend our stainless steel cleaner no. See enclosed service booklet for order address. · · · Clean the extractor hood with a hot soap solution or a mild window cleaner. IMPORTANT: No liquids may enter the air outlet slot. Do not scrape off dried-on dirt but wipe off with a damp cloth. When cleaning the grease filters, remove grease deposits from accessible parts of the housing. This prevents the risk of fire and ensures that the extractor hood continues operating at maximum efficiency. Aluminium, coated and plastic surfaces: · · · Do not use dry cloths. Do not use aggressive, acidic or caustic cleaners. Clean the operating buttons with a mild soapy solution and a soft, damp cloth only. Do not use stainless-steel cleaner to clean the operating buttons. Observe the warranty regulations in the enclosed service booklet. 12 Replacing the light bulbs 1 Switch the extractor hood off and isolate it by removing the mains plug or by switching off the fuse. When operating, the fluorescent light bulbs get very hot. Even after a while, there is still a risk of being burnt. [. . . ] If necessary use special wall plugs. 77/ 8" 135/8" Installation of the extractor hood: 1 2 3 Using the drilling template mark the position of the screws on the ceiling. Drill 4 holes Ø 5/ 16" for the wall plugs. Both screws are placed in a position, in which at a later stage of the installation the key-holes of the supporting frame are found (namely back left and front right from the control panel of the hood). Adjust the support frame to the desired height and secure with 8 screws (12 screws for the longer ventilation ducts). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GAGGENAU AI280720

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GAGGENAU AI280720 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag