User manual GAGGENAU AT400101

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GAGGENAU AT400101. We hope that this GAGGENAU AT400101 user guide will be useful to you.

Lastmanuals help download the user guide GAGGENAU AT400101.


Mode d'emploi GAGGENAU AT400101
Download
Manual abstract: user guide GAGGENAU AT400101

Detailed instructions for use are in the User's Guide.

[. . . ] Switch off the ventilation when you flambée meals!Do not pour any liquid into the housing. If liquid accidentally enters the housing, it will come out at the base. Do not use highpressure or steam jet cleaning devices. [. . . ] When installing together with Vario appliances, the appliance cover (VD 400) needs to be removed. The frying basket holder cannot be used when operating the deep fryer VF 411 in front of the table ventilation. RISK OF POISONING If the extractor hood is operated at the same time as a heating appliance which is dependent on ambient air, there is a risk of poisoning due to combustion gases being drawn back in. · Maintenance If the appliance does not function correctly, check the household fuses first. If the power supply is functioning correctly, but your appliance still does not work, please contact your dealer or your local Gaggenau customer service agency. · · Adequate intake air must therefore always be provided. An intake/exhaust air wall box alone does not ensure compliance with the limit value. Repairs may only be carried out by authorised technicians, in order to guarantee the safety of the appliance. Non compliance with these recommendations results in the warranty coverage becoming invalid. The appliance must always be disconnected from the mains when being repaired. If all poles of the appliances cannot be isolated from the mains by removing an accessible plug, an isolating device with a contact gap of at least 3 mm must be installed (e. g. domestic fuse). Note: When making your evaluation, always consider the entire ventilation system in the home. Include the advice of a competent heating engineer when making your evaluation. · If the extractor hood is used in circulating air mode only, it can be operated without any restrictions. 5 Features of your new appliance Combination of AT 400-101 with Gaggenau hob CE 490 /CI 490 cover light air inlet control panel Combination of AT 400-131 with three Gaggenau Vario 400 series appliances Control panel grease filter saturation display light delay shut off intensive mode ventilation level 3 ventilation level 2 ventilation level 1 ventilation off 6 Accessories Special accessories Please order the following special accessories for air recirculation mode: Accessories for installation You can order the following accessories for installation: · · AA 409-100: Activated carbon filter and grease fine filter for AT 400-100 AA 409-130: Activated carbon filter and grease fine filter for AT 400-130 · · AA 409-400: Furniture support 86 cm for AT 400-101 AA 409-430: Furniture support 116 cm for AT 400-131 Recommended as bearer for the worktop, instead of a cabinet frame, or to support the fan housing, replacing the need for a cabinet base. You can order the following special accessories for air exhaust mode: · · · · · 476 358: Grease fine filter for AT 400-100 476 363: Grease fine filter for AT 400-130 · · · · · · AA 409-900: Telescopic extension for AT 400-101 AA 409-930: Telescopic extension for AT 400-131 Telescopic extension max. 110 mm between table ventilation and fan housing. AA 010-410: Air exhaust grille for AT 400-101/131. ZB 020-090: Additional louvre for air exhaust grille AA 010-410. Height 30 mm, several louvres can be installed. : Cylindrical pipe ducts for air extraction AD 8. . : Flat rectangular ducts for air extraction You can order the following special accessories: AA 400-200: Glass cover, frosted, 106 cm, thickness 6 mm with spacers AA 400-230: Glass cover, frosted, 136 cm, thickness 6 mm with spacers AA 400-010: Wooden cutting board, beech, 53 cm 7 Operating principle The table ventilation is an effective air recirculation system, which extracts the vapours directly behind the cooktop towards the rear. The centrifugal grease filters separate the greasy components from the extracted air. The grease fine filter absorbs any remaining grease particles. The activated carbon filter in the fan housing traps odours, the exhaust outlet for the clean air is in the furniture plinth. For air recirculation mode in combination with VR or VP: observe the tips to avoid smoke when frying or grilling. For air exhaust mode an exhaust air duct is fitted onto the blower outlet instead of fitting the activated carbon filter. air intake centrifugal grease filters grease fine filter (fleece filter) grease collecting trays fan housing activated carbon filter (only for air recirculation mode) exhaust outlet 8 Operation When pressed, all functions selection keys are backlit in green, except 0 ("Motor off"). Ventilation Three fan speeds and one intensive speed are available. You set the fan speed required for each respective cooking process by pressing the function selector keys 1, 2, 3 or Int. Intensive mode The Int key for the intensive level should be pressed when browning and frying in an open pan. If you have switched on the ventilator by selecting the intensive level, it will be switched off again automatically after 5 minutes. If you press the Int key while the ventilator is running at fan level 1, 2 or 3, the electronic control will switch back automatically to the previously selected fan level after 5 minutes. If you would like to end the intensive level before the 5 minutes have elapsed, press the 0 key ("Motor off") or select a different level. [. . . ] Refit the centrifugal grease filters in the reverse order (from left to right). Grease fine filters do not contain any polluting substances. They can be disposed of through the household refuse collection. 13 Lamp replacement Wait until the appliance has cooled down before replacing lamp. 1 2 3 4 5 6 Disconnect the appliance from the mains (switch off fuse). First turn florescent lamp in the socket, then lift off fluorescent lamp. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GAGGENAU AT400101

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GAGGENAU AT400101 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag