User manual GARY FISHER AXIOM COMPUTER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GARY FISHER AXIOM COMPUTER. We hope that this GARY FISHER AXIOM COMPUTER user guide will be useful to you.

Lastmanuals help download the user guide GARY FISHER AXIOM COMPUTER.


Mode d'emploi GARY FISHER AXIOM COMPUTER
Download
Manual abstract: user guide GARY FISHER AXIOM COMPUTER

Detailed instructions for use are in the User's Guide.

[. . . ] Awareness of potential road, trial, or traffic problems should be your main concern. COMPUTER FUNCTIONS Speedometer Display (SPD) Current riding speed is indicated on the top line of the display with the SPD icon. Instantaneous speed has a display range of 2. 5 ­ 99. 5 M/h (4 ­ 99. 5 Km/h). Automatic Timer Stopwatch (ATM) The Automatic Timer Stopwatch is displayed on the lower line with the ATM icon. The ATM stopwatch is automatically activated by wheel movement. [. . . ] Carefully tighten the quick ties making sure you maintain the proper space between the magnet and the axiom. Trim the excess quick tie strap using a scissors or fingernail clipper. Tighten the magnet screw, but be careful not to over tighten as this can damage the fitting. Wind the wire upward around the front brake cable until the wire is adjacent to the handlebar, allowing enough slack for free movement of the steering assembly cables. Attach the bracket to the handlebar on either side of the stem. The bracket goes onto the handlebar with the wire toward the rider side of the bar. Use the appropriate rubber shim between the bracket and handlebar to provide a secure fit. Shims will prevent slipping Attaching the Computer to the Bracket 1. Position the axiom unit to the inside of either the right of left fork blade anywhere from 3-6 inches up from the fork blade tip. Attach the axiom to the fork blade with the quick ties but do not tighten the ties completely until final adjustment is complete. 1. Route the axiom wire up the back of the fork blade or wind the wire around the blade, making sure that the wire is not loose and that you leave enough wire to reach the handlebar. Secure the wire to the fork blade immediately above the axiom and at the top of the fork blade, using the adhesive strips that are provided or electrical tape. The Fisher Axiom Computer attaches to the mounting bracket by sliding the unit onto the bracket from the back until it snaps firmly into position. To remove the computer from the bracket, place your thumb against the back of the mounting bracket and pull the computer toward you with your index finger. 5 4 COMPUTER SET UP Battery Installation BUTTON FUNCTIONS Setting Miles/ Kilometers and Wheel Size 1. Press mode computer key to enter AVS/ODO mode. Press and hold mode key for over 2 seconds until m/h begins to flash. Press adjust key to select miles (m/h) or kilometers (km/h) display. Press mode key to confirm choice and advance to wheel size setting. Adjust the flashing digit with the adjust button, confirm choice by pressing mode button, and advance to next flashing digit. Adjust and/or confirm all flashing digits. Wheel Size Setting The wheel size setting number is equal to the distance, in millimeters, that your front wheel travels during one complete revolution. Each time the wheel magnet passes the axiom unit on your fork, the axiom sends an impulse to the computer telling it that your wheel has completed one revolution. The computer calculates this distance vs. time to give you accurate readings for the various modes. [. . . ] . 2110 Desired Function Advance Digits While Programming Set Digits While Programming Set Clock Set Miles/Kilometers/Wheel Size Enter ATM "Lap Timer" Display Reset ATM, DST, AVG and Max Which Key to Press Left Key Right Key Right for 2 Sec. Left for 2 Sec Right for 2 Sec. Notes Hold for Fast Advance In MXS/Clock Screen In AVS/ODO Screen In any Screen In SPD/ATM Screen 700 x 20c . . 2160 TROUBLESHOOTING · No Speed Reading Improper magnet to axiom alignment, computer improperly installed in bracket. · Slow Display Response Temperature is outside operation limit (0°-55°C). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GARY FISHER AXIOM COMPUTER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GARY FISHER AXIOM COMPUTER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag