User manual GENERAL ELECTRIC MERLIN 1255052

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GENERAL ELECTRIC MERLIN 1255052. We hope that this GENERAL ELECTRIC MERLIN 1255052 user guide will be useful to you.

Lastmanuals help download the user guide GENERAL ELECTRIC MERLIN 1255052.


Mode d'emploi GENERAL ELECTRIC MERLIN 1255052
Download
Manual abstract: user guide GENERAL ELECTRIC MERLIN 1255052

Detailed instructions for use are in the User's Guide.

[. . . ] GE Infrastructure Water and Process Technologies MerlinTM Point of Use Drinking Water System Installation and Maintenance Manual SAFETY GUIDES Read and follow all steps and guides carefully before installing and using your reverse osmosis system. Do not use this product to make safe drinking water from non-potable water sources. Do not use the system on microbiologically unsafe water, or water of unknown quality without adequate disinfection before or after the system. This reverse osmosis system contains replaceable components (membrane elements). [. . . ] Slide the standoff onto the threaded tube, followed by the standard washer and nut. Screw the threaded hose connector on the end of the threaded tube. Connect the blue 3/8-inch product tubing by firmly pushing it into the connector. If using the air gap module, push the black 3/8-inch tubing onto the small hose barb from the collar. The red 1/2-inch tubing is pushed onto the large hose barb. The horseshoe clip is positioned around the threaded pipe under the sink and above the standoff. Tighten the nut against the clip to hold the faucet in position. Do not try to drill mounting holes anywhere on the system. If putting above ground/cabinet level, a sturdy, permanent shelf is recommended. 12 Rev B THE BASIC REVERSE OSMOSIS SYSTEM Recommended Placement Positions Locking Bar The Merlin assembly should be positioned in one of two ways. The first position is with the unit standing upright using the support leg with the sumps horizontal. The tubing is directed to provide the best fit. The second position, sets the unit on end so the manifold is horizontal and the sumps are pointing up. The tubing is directed upward and the locking bar is down to lock the tubing connections. The table below shows the coding system for the fitting connections. Each fitting has a unique "keyed" socket on the manifold. Each fitting also has a graphic symbol molded into the elbow with a corresponding symbol on the manifold. First Position Connector Symbol Second Position Connection Flushing (optional) Feed-Inlet Concentrate Product Tubing Color Blue Natural Black Blue O WARNING: Be sure to lubricate the O-rings on the fitting elbows prior to inserting into manifold. WARNING: Do not turn the incoming water valve on until the locking bar is in place. NOTE: If the installation is not using the optional flush tank, the top connection will not have tubing. Instead a plug will be inserted into the fitting. Do not remove plug unless you are attaching the tubing and the flush tank. THE BASIC REVERSE OSMOSIS SYSTEM 13 Rev B When all of the connections have been made, use the locking bar to hold the fittings in position. Match the symbols on the locking bar to the corresponding symbols on the manifold. Symbols Figure 6 Locking Bar STEP 6 SYSTEM STARTUP 1. If the flush tank is not installed, the 1/4-inch port on the manifold must be plugged. Position manifold horizontal with openings facing up. Remove new membrane elements from packaging. CAUTION: Elements contain a foodgrade preservative. [. . . ] Murdock USA Feed Valve Tee - 5/8" x 5/8" x 1/2" OD Tubing -SeaTech Feed Valve Tee - 14 mm x 14 mm x 1/2" OD Tubing -SeaTech Feed Valve Tee - 15 mm x 15 mm x 1/2" OD Tubing -SeaTech Feed Valve Tee - 3/8" x 3/8" threaded x 1/2" Tubing -SeaTech Feed Valve Tee - 1/2" x 1/2" threaded x 1/2" Tubing -SeaTech 10-micron Sediment Prefilter Post Filter Mounting Clip Kit NON-STOCKED INDIVIDUAL COMPONENTS Part Number 1240626 1240627 1240628 1240624 1240625 Description Individual Collet Lock Clip- 1/4-inch Red - John Guest PN PIC1808R-X Individual Collet Lock Clip- 3/8-inch White - John Guest PN PIC1812W-X Individual Collet Lock Clip- 1/2-inch Blue - John Guest PN PIC1816B-X 1/4-inch JG Plug - John Guest PN P10808S Faucet Connection Fitting - John Guest PN CI3212U7S Recommended Source John Guest USA John Guest USA John Guest USA John Guest USA John Guest USA Spare parts are available through your installing water treatment dealer. MERLIN PARTS LIST 23 Rev B DIMENSIONS Performance Specifications1, 2 Permeate Flow Rate TDS Rejection (NaCl)3 Minimum 0. 33 gals/min (1. 25 Lpm) 90% Maximum 0. 75 gals/min (2. 84 Lpm) 99% Average 0. 50 gals/min (1. 89 Lpm) 93% Minimum and Maximum Operating Conditions Condition Minimum Inlet Pressure 40 psi (2. 76 bar) Inlet Temperature 40°F (4. 44°C) Inlet TDS 50 mg/L Inlet Hardness 0 mg/L (0 grain) Inlet Chlorine 0 mg/L Inlet Iron 0 mg/L Inlet Manganese 0 mg/L Inlet pH 4 Inlet Turbidity 0 Maximum 80 psi (5. 52 bar) 100°F (37. 78°C) 2, 000 mg/L 171 mg/L (10 grain) 1. 0 mg/L 0. 1 mg/L 0. 05 mg/L 10 1 NTU 1. Based on 50 psi (3. 44 bar), 77°F (25°C), 750 mg/L NaCl, 23. 7% Recovery 2. System is designed for use on potable water systems only. Specifications based on GE Osmonics testing data. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GENERAL ELECTRIC MERLIN 1255052

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GENERAL ELECTRIC MERLIN 1255052 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag