User manual GOLDSTAR HB-152CE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GOLDSTAR HB-152CE. We hope that this GOLDSTAR HB-152CE user guide will be useful to you.

Lastmanuals help download the user guide GOLDSTAR HB-152CE.


Mode d'emploi GOLDSTAR HB-152CE
Download
Manual abstract: user guide GOLDSTAR HB-152CE

Detailed instructions for use are in the User's Guide.

[. . . ] This symbol indicates the possibility of injury or damage to property only. Meanings of symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction. WARNING Always install the expansion panel(s). · Improper assembly or installation may cause incorrect operation, including injury, fire, and electric shock hazards. Do not place the power cord near a heater. [. . . ] Remove the 3 screws which fasten the condenser. Move the condenser to the left carefully. Remove the fan and then pull out the shroud. Re-install by referring to the removal procedure. Figure 22 16 Room Air Conditioner --7-- Disassembly 3. Remove the control box cover and housing of the motor in the control box. Remove the 2 screws which fasten the motor from the mount motor. Re-install the components by referring to the removal procedure, above. (See Figure 23) Figure 23 Electrical Parts 1. Remove the nut which fastens the terminal cover. Remove all the leads from the overload protector. Re-install the component by referring to the removal procedure, above. Discharge the refrigerant system using a FreonTM Recovery System. ROTARY SWITCH MODEL : ROTARY SWITCH TYPE MODEL 1. Remove the 2 screws which fasten the rotary switch. Disconnect all the leads of the rotary switch terminals. Re-install the components by referring to the above removal procedure. Disconnect the grounding screw from the control box. Remove a screw which fastens the clip cord. Re-install the component by referring to the above removal procedure, above. (Use only one ground-marked hole for ground connection. ) 8. If the supply cord of this appliance is damaged, it must be replaced by the special cord. (The special cord means the cord which has the same specification marked on the supply cord attached at the unit. ) Figure 29 Figure 30 Refrigerating Cycle CAUTION: Discharge the refrigerant system using a FreonTM Recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the FreonTM. [. . . ] Check the wire connections; if loose, repair or replace the terminal. If the wires are disconnected, refer to wiring diagram for identification, and replace the wires. Check the wire connections; If not according to the wiring diagram, correct the connections. If not at the lowest number, set TEMP control to this setting and restart the unit. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GOLDSTAR HB-152CE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GOLDSTAR HB-152CE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag