User manual GRACO CORIOLIS METER KIT INSTRUCTIONS PARTS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GRACO CORIOLIS METER KIT. We hope that this GRACO CORIOLIS METER KIT user guide will be useful to you.

Lastmanuals help download the user guide GRACO CORIOLIS METER KIT.


Mode d'emploi GRACO CORIOLIS METER KIT
Download

You may also download the following manuals related to this product:

   GRACO CORIOLIS METER KIT INSTRUCTIONS PARTS REV 9-2010 (2007 ko)

Manual abstract: user guide GRACO CORIOLIS METER KITINSTRUCTIONS PARTS

Detailed instructions for use are in the User's Guide.

[. . . ] Instructions-Parts Coriolis Meter Kit 313599B ENG For use with Graco ProMix 2KS Proportioners. Uses vibration to measure fluid flow in low flow applications or with light viscosity, shear sensitive, or acid catalyzed materials. Bare meter is approved for use in explosive atmospheres [Class I, Div I, Group C and D, or Class I, Zone I, EExd(ia) IIC T1-T6] if all installation requirements are met. (3 mm) diameter metering tube 2300 psi (16 MPa, 160 bar) Maximum Working Pressure Part No. [. . . ] Install the strain relief (12). See Hazardous Location Intrinsically Safe Installation Requirements on page 5 and FIG. Install the power cable according to all local electrical codes. Do not operate proportioner with equipment enclosure doors/covers open. Disconnect power source before servicing or doing electrical wiring. Turn proportioner power off and disconnect power source. Bring the user-provided power cable (PC) from the hazardous area into the non-hazardous area. Follow all local and national codes for flameproof, explosion proof, or increased safety protection. Open the EasyKey enclosure with its key. There are two knockouts on the top of the EasyKey enclosure. Knock out one, depending on whether the Coriolis meter will be on the A or B side. 11 FIG. The 24 Vdc can be supplied from the EasyKey. · Installation of the power input circuit (PC) in the hazardous location must comply with all local and national electrical code requirements relating to flameproof or explosion proof methods of protection. · Required electrical components to complete a compliant hazardous location installation of the power input circuit to the meter are not provided with the meter kit. * For P/N 15T633 order Coriolis Meter Kit 258150. For P/N 15T634 order Coriolis Meter Kit 258151. FIG. System Layout for Coriolis Meter (B Side Meter Installation Shown) 313599B 9 Installation Meter Signal Cable 1. Route the 20 ft (6. 1 m) signal cable (4) into the fluid panel and through a strain relief (SR) on the left side of the fluid panel enclosure. Connect the signal cable's green ground wire to the ground terminal bar (GT). Connect the white and black wires to J3 on the fluid panel control board (CB). Use pins 2-3 for Flow Meter A and pins 5-6 for Flow Meter B. The signal cable (4) must be connected to the Coriolis meter with a Zone I Ex d IIA or Class I Div I cable gland. 5. Flow Meter Signal Wire Schematic 1 2 3 4 5 6 COM (BLACK) SIG (WHITE) SHIELD/GRN COM (BLACK) SIG (WHITE) SHIELD/GRN FLOW METER A FLOW METER B J3 GROUND TERMINAL J3 Connector; see wiring schematic above FIG. Signal Cable Connections at Fluid Panel Board 10 313599B Installation Power and Signal Cable Connections at Meter The signal cable (4) is factory assembled to the meter. If cables need servicing or replacement, see FIG. [. . . ] With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco's written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GRACO CORIOLIS METER KIT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GRACO CORIOLIS METER KIT will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag