User manual GRACO CYCLEFLO II 309004C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GRACO CYCLEFLO II. We hope that this GRACO CYCLEFLO II user guide will be useful to you.

Lastmanuals help download the user guide GRACO CYCLEFLO II.


Mode d'emploi GRACO CYCLEFLO II
Download
Manual abstract: user guide GRACO CYCLEFLO II309004C

Detailed instructions for use are in the User's Guide.

[. . . ] Use only genuine Graco parts and accessories. Repair or replace worn or damaged parts immediately. Do not exceed the maximum working pressure of the lowest rated system component. Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. [. . . ] Always follow local and applicable electrical codes. The CycleFlo II will halt the pump cycle whenever the 120 volt signal is removed. Installation Electrical Connections An access hole with a strain relief installed has been provided for the external power connection. Due to the unique requirements of each installation, access holes have not been provided for the other optional external wiring connections such as the external air supply valve signal. Have a qualified electrician determine the proper strain relief, wire type, and wire size for your particular application. When positioning or adding access holes, be careful not to damage any internal components. Failure Fire, Explosion, and Electric Shock to use the proper strain relief, wire type and wire size can cause damage to internal components Hazard or personal injury. To reduce the risk of fire, explosion, or electric shock: There are three connections on the 120V input · The power source conduit is not an signal terminal block (see Fig. The two rightadequate grounding for the system. The hand connections are for line and neutral wires unit must be grounded to a true earth respectively. The left-hand connection is for a ground. · A qualified electrician must complete all grounding and wiring connections and check the resistance. · Refer to your local code for the requirements for a "true earth ground" in your area. 5 309004 Fig. 1 - Electrical Diagrams Cycle Rate Adjustment Relay 120 Volt Signal Solenoid Valves Pneumatic Connections 6 309004 The integrated air valves, have a common air inlet (1/4" NPT) port and two outlet ports A and B (1/4" Tube) toward the front of the unit. Do not exceed 120 psi at the air inlet to the unit. Refer to your pump owner's manual for the maximum air pressure limit of the pump. B Outlet Port Exhaust Muffler Common Air Inlet Strain Relief for Power Supply LIne A Outlet Port Failure to use the following recommended valve can cause damage to the unit and possible personal injury. Follow the pressure relief procedure in the pump manual before moving or servicing the pump. The A and B outlet ports are to be connected to the A and B ports respectively on the Husky 205, or to the two air valve control ports located on the air motors of pumps larger than the Husky 205. On pumps larger than the Husky 205, a three way solenoid valve (Graco Part Number 115606 or equivalent) MUST be installed on the main air supply to the pump. This ensures that pressure is not generated by the pump when the controller is not operating. The same signal used to start the CycleFlo II controller can also control this valve. 7 309004 Setup & Adjustment Cycles Per Minute (CPM) Rate The pump cycle rate is adjustable to accommodate different pump sizes, varying product viscosities and product delivery speed. The pump cycle rate is measured in Cycles Per Minute (CPM), i. e. the number of times the pump performs a pump cycle in one minute. One pump cycle consists of a momentary pressurization of each one of the two diaphragms. Adjustment The CycleFlo II comes with a cycle rate adjustment relay that can be adjusted using a screwdriver to control the energizing and deenergizing rate of the built-in solenoid valves. [. . . ] This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco's written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présent document ainsi que de tous les documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées sera en Anglais. Graco Phone Number For the latest information about Graco products, visit www. graco. com. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GRACO CYCLEFLO II

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GRACO CYCLEFLO II will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag