User manual GRACO QUIET VISCOUNT II PARTS LIST

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GRACO QUIET VISCOUNT II. We hope that this GRACO QUIET VISCOUNT II user guide will be useful to you.

Lastmanuals help download the user guide GRACO QUIET VISCOUNT II.


Mode d'emploi GRACO QUIET VISCOUNT II
Download
Manual abstract: user guide GRACO QUIET VISCOUNT IIPARTS LIST

Detailed instructions for use are in the User's Guide.

[. . . ] Instructions­Parts List Quiet ViscountR II Hydraulic Motor Used as hydraulic drive for reciprocating pumps. For professional use only. Model 223646, Series B 1500 psi (10 MPa, 103 bar) Maximum Hydraulic Fluid Input Pressure Patent No. 4, 792, 291 Foreign Patents Pending 308048K ENG Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. Table of Contents Warnings . [. . . ] Hydraulic power supply and air compressor: follow manufacturer's recommendations. 2 14 04468 6 308048 Service Pressure Relief Procedure Before you start: Be sure you have all necessary parts on hand. An asterisk behind a reference number in the parts list, for example (21*), indicates that the part is included in the repair kit. Clean all parts as you disassemble them and inspect them for wear or damage. Use Loctiter TL­242 thread sealant, or the equivalent, when thread sealant is specified. WARNING SKIN INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally. Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you: D D D D are instructed to relieve the pressure, stop spraying, check or service any of the system equipment, or install or clean the spray tip. Disassembly (Refer to Fig. 3) NOTE: Use all the replacement parts that are in the repair kit. 1. Close the supply line shutoff valve, and then the return line shutoff valve. Hold a metal part of the gun firmly to the side of a grounded metal pail, and trigger the gun to relieve pressure. Stop the pump at the bottom of its stroke. Open the drain valve (required in your system), having a container ready to catch the drainage. Leave the drain valve open until you are ready to spray again. If you suspect that the spray tip or hose is completely clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the tip guard retaining nut or hose end coupling and relieve pressure gradually, then loosen completely. Flush the displacement pump if possible. WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7. Relieve the pressure. NOTICE Avoid getting dust or dirt in the motor during service. Cleanliness is essential when repairing an hydraulic motor. Disconnect the hydraulic hoses and plug all hydraulic connections and lines to prevent contamination. 308048 7 Service Disassembly (continued ­ refer to Fig. 3) NOTICE When removing the displacement pump, hold it securely. The pump is heavy and could fall off the motor. Disconnect the displacement pump from the motor, as explained in your separate pump manual. Pull the trip rod and piston from the lower housing (25) and cylinder (29). [. . . ] stroke 5 02631 14 308048 Technical Data Category Maximum hydraulic fluid input pressure Maximum hydraulic fluid flow Hydraulic fluid consumption Effective piston area Piston rod diameter Stroke length Thrust at 1500 psi (10 MPa, 103 bar) Weight Loctiter is a registered trademark of the Loctite Corp. Sound Data Hydraulic Pressure 1500 psi (10 MPa, 103 bar) dB(A) at 20 cycles per minute 70 dB(A) at 30 cycles per minute 78 dB(A) at 60 cycles per minute 79 Data 1500 psi (10 MPa, 103 bar). (43. 5 kg) 308048 15 Graco Warranty and Limitation of Liability Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special extended or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GRACO QUIET VISCOUNT II

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GRACO QUIET VISCOUNT II will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag