User manual GRASS VALLEY 8972PX DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GRASS VALLEY 8972PX. We hope that this GRASS VALLEY 8972PX user guide will be useful to you.

Lastmanuals help download the user guide GRASS VALLEY 8972PX.


Mode d'emploi GRASS VALLEY 8972PX
Download
Manual abstract: user guide GRASS VALLEY 8972PXDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] 78 8972PX Protection Switch Key Features · Two-input robust failure-proof changeover switch · Third alternate input, available for switching, non relay-protected · Supports HD-SDI, SD-SDI, and DVB ASI with auto-sensing capability · Will maintain signal path in the event of power failure or when the front card is removed · Eight outputs, including: -- One main relay-protected output with passive bypass path -- One electronic output follows main -- Three output pairs can be set to follow main or backup or can be switched to primary, secondary or alternate inputs · Line switching in driven switch mode (SD/HD-SDI syncronous input signals) · External control via GPI or Ethernet · Autonomous control by: -- Signal (carrier) loss detection -- Incorrect signal format -- EDH/CRC error (selectable threshold) -- DVB-ASI PID loss -- DVB-ASI packet loss · GeckoFlex dual-slot rear module · Asserting external control of the module automatically turns off autonomous control The 8972PX is a full-time signal protection switch. [. . . ] The 8972PX fulfils the basic requirement of any protection system by not adding failure modes to the existing signal path. In the event of a power failure, or even if the front control module is completely removed, the Program Output signal will continue to pass from the previously selected input as a fail-safe relay path will latch the selected signal to the output. In driven mode it can be configured by GPI or Ethernet. Alternate in Switchable Distributed Out Switchable Distributed Out GPI I/O Switchable Distributed Out Relay Protected Out Primary In 8900PX-DR J1 J2 Switchable Distributed Out Switchable Distributed Out Switchable Distributed Out Main Distributed Out Secondary In J3 J4 J5 J6 J7 J8 J9 J10 All parameters can be configured via the web browser interface and main parameters via the Newton Control Panel. NetConfig and NetCentral are supported respectively for remote configuration and product health monitoring. [. . . ] Asserting GPI control or other manual controls will disable autonomous control. Primary Secondary Alternate GPI In Equalization & Reclocking Equalization & Reclocking Equalization & Reclocking Input Signal Monitors Autonomous Control Main Protected Output Bypass Relay Controls Latching Relay Control REAR MODULE FRONT MODULE Main Distributed Output GPI Out Main Local Control Switch Manager Backup GPI Out Applications · Select between primary, secondary, and alternate inputs paths · Switch to alternate input (i. e. , apology slide) when primary and secondary inputs are both failing Configurable Output Pairs Network Control GPI Control Switchable Distributed Outputs Network Interface GPI In Specifications Supported Frame Types GeckoFlex with 8900NET (Net Card) for configuration Ordering Information Specifications GPI ·Switchtoprimaryinput ·Switchtosecondaryinput ·Switchtoalternateinput This module can be mounted in a GeckoFlex frame but not in other 8900 series frames, including Gecko-A or Gecko-V frames and it requires two slots. Power Rating 9. 0 Watts ­ dual slot Inputs SD/HD-SDI or ASI: Three ·Input equalization: up to 125m HD/330m SD/ASI (when signal is not bypassed) ·Formatssupported:1080i@59. 94, 50, 720p @ 59. 94, 50, 480i @ 59. 94 576i @ 50 ·DVBASI:yes GPO Primary input status (failed/good) Secondary input status (failed/good) Alternate input status (failed/good) Switch state (primary/secondary/alternate) 8972PX SD/HD/ASI protection switch, front and dual rear module set 8900PX-DBS D-connector backshell option, fitting with rear high density Control and Monitoring SNMP: Monitoring and switching control Web page configuration: Yes Local configuration: Switching control only Newton support: Yes NetConfig support: Yes Outputs Protected outputs: One Insertion loss on protected output when bypassed: Equivalent to less than 20m of Belden 1694A cable Return loss: <15 dB (when signal is not bypassed) Distributed outputs: Seven Return loss: <15 db For detailed specifications, installation, and setup instructions see: www. grassvalley. com/docs/modular [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GRASS VALLEY 8972PX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GRASS VALLEY 8972PX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag