[. . . ] INSTALLATION INSTRUCTIONS FOR
GTO/PRO SL-5100 and GTO/PRO SL-6100 Advanced AC Powered Slide Gate Operators
LI
US
STED
WARNING!
· READ ALL INSTRUCTIONS COMPLETELY before attempting installation and use; failure to do so may result in serious injury or death!· This unit must only be installed by an experienced technician!Contact with gate operator circuitry can cause serious injury or death!Operator power must be disconnected before servicing! [. . . ] Using a fingertip, roll the limit nuts along the travel shaft until the correct open and closed gate positions are determined. If the gate opens from LEFT to RIGHT (see illustration below): the right limit switch adjusts the closed position. The left limit switch adjusts the open position. If the gate opens from RIGHT to LEFT (see illustration below): the left limit switch adjusts the closed position. The right limit switch adjusts the open position.
Limit Adjustment Lock
Limit Switch Plate
Test the operator to verify that the limit switches are properly set. The operator should open and close the gate completely. After properly setting the limit switches, the control board must be set according to the operator application. The system accessories should also be connected to the control board.
Lift limit switch plate to release, then adjust limit nut.
Left Limit Nut
OPEN position stop if gate opens LEFT to RIGHT CLOSED position stop if gate opens RIGHT to LEFT
Right Limit Nut
CLOSED position stop if gate opens LEFT to RIGHT OPEN position stop if gate opens RIGHT to LEFT
Limit Switch
Limit Switch
Limit Switch Plate
Travel Shaft
The closer the limit nut is to the limit switch, the less distance the gate will travel to open or close.
13
ADVANCED GATE OPERATOR CONTROL BOARD
T1SEC JP1 JP2
+300VDC
DUAL GATE INTERFACE
+
STATUS LED
RX
24VDC
ACCES. PWR.
+ AUX 2 ALARM LOCK 2
LOCK 1
TX
+
QC1
QC2
GRN GTO RED RCVR. BLK
DANGER
HIGH VOLTAGE
400 Volts DC for 5 minutes after power is turned off!
EDGE 6
EDGE 5
EDGE 4
(Not Actual Size)
BATT BATT TEMP T1-P-CT F1 Replace with 1/2 Amp Max
EDGE 3
LEARN/RESET
CLS. SENS.
PWR OK TIMER ON OBSTRUCT
MIN MAX
EDGE 2
EDGE 1
OPN. SENS.
COM
COM
BATT+
CLOSE
MAX TIME SENSOR ERR. INTERN. ERR.
MIN MAX 1
MIN
MAX
COM
OPEN
INERTIA
TIMER
120
FIRE DEPT. LOOP
GTO Inc. , Tallahassee, FL
SWNG/SLD MAST/SLV GATE R/L SEQUENC 1 SEQUENCE 2 TMR. OFF/ON NORM/LEARN OPEN/CLOSE
1 2 3 4 5 6 7 8
SAFETY LOOP COM ENTRY LOOP
ON
FREE EXIT COM
CYCLE
BATT
SW
24AC
24CT 24AC
14
CONTROL BOARD SETTINGS
THESE SETTINGS SHOULD BE ADJUSTED ONLY BY AN EXPERIENCED INSTALLER OR TECHNICIAN!LEARN/RESET:
1) Use to set transmitter code in control board memory. 2) Press this button to clear the diagnostic and error LEDs.
LEARN/RESET
ON
SWNG/SLD MAST/SLV GATE R/L SEQUENC 1 SEQUENCE 2 TMR. OFF/ON NORM/LEARN OPEN/CLOSE
GTO Inc. , Tallahassee, FL
SWNG/SLD (swing or slide gate operation): SWNG = swing gate SLD = slide gate [factory default is SLD]. MAST/SLV (master or slave unit): This DIP switch must be set to MAST for single gate applications. For dual gate applications set one control board to MAST and the other to SLD [factory default is MAST]. See installing a Dual System on pages 22-23. GATE R/L (gate opens right or left): The direction a gate opens is determined by standing inside the property and facing toward the gate. [. . . ] Products received at the factory without an RGA number will not be accepted. Replacement or repaired parts are covered by this warranty for the remainder of the warranty period or six (6) months, whichever is greater. GTO will pay shipping charges (equivalent to United Parcel Service ground rate) for return to owner of items repaired under warranty. The manufacturer will not be responsible for any charges or damages incurred in the removal of the defective parts for repair, or for the reinstallation of those parts after repair. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE GTO PRO-SL 51006100
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.