User manual GTO PRO-SW 25502502

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GTO PRO-SW 25502502. We hope that this GTO PRO-SW 25502502 user guide will be useful to you.

Lastmanuals help download the user guide GTO PRO-SW 25502502.


Mode d'emploi GTO PRO-SW 25502502
Download
Manual abstract: user guide GTO PRO-SW 25502502

Detailed instructions for use are in the User's Guide.

[. . . ] Installation Manual for the LI STED US Dual Automatic Gate Operators This equipment is similar to other gate or door equipment and meets or exceeds Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has hazards associated with its use and therefore by installing this product the installer and user accept full responsibility for following and noting the installation and safety instructions. Failure to follow installation and safety instructions can result in hazards developing due to improper assembly. You agree to properly install this product and that if you fail to do so GTO, Inc. [. . . ] Wires coming up from the ground should be run through PVC conduit to protect them from lawn mower blades, weed eaters, and grazing animals. Be sure to bury the wire laid in the trench. Step 4 Feed the low voltage wires upward through the strain relief opening on the lower left of the control box. Pull 6" to 8" of wire into the control box and tighten the strain relief screw to secure the wires. WARNING!DO NOT PLUG THE TRANSFORMER INTO AN OUTLET DURING THIS STEP!THE TRANSFORMER MUST ONLY BE PLUGGED INTO AN OUTLET DURING STEP 7! Low Voltage Wire from Transformer Power Cable from Opener Arm PVC Pipe Step 5 RED BLACK ~~ 18VAC Strip 3/16" off the ends of the low voltage wire and twist tightly. Attach these ends to the 18VAC terminals located on the POWER IN terminal block (see illustration at right). Be certain not to let the exposed wires touch each other!Insert one transformer wire into an 18VAC terminal. Insert the other transformer wire into the remaining 18VAC terminal. The transformer wires can be connected to the 18VAC terminals regardless of color. Tighten set screws against exposed end of wires. A dab of household petroleum jelly on each terminal will help prevent corrosion. ­ + NC RLY-COM NO SOLAR RELAY OUT Low Voltage Wire from AC Transformer GRN WHT BLUE BRN ORG RED BLK SLAVE INPUTS MASTER INPUTS SWITCH GRN WHT BLUE BRN ORG RED BLK 22 Step 6 Strip 1/2" of insulation from the ends of the low voltage wire. Attach these stripped ends to the transformer terminals. A dab of household petroleum jelly on each terminal will help prevent corrosion. Make sure the exposed wires do not touch each other! Step 7 Plug the transformer into the electrical outlet. (Use of a surge protector with the transformer is strongly recommended. ) HINT: Keep a few mothballs in the control box to discourage insects from entering it and damaging the control board. 23 SURGE PROTECTOR Transformer CONTROL BOARD SETTINGS DIP Switches NOTE: Leave DIP Switch #3 in the OFF position untill installation is complete, to prevent gate from automatically closing during installation. 1 2 3 4 5 6 7 ON 1 2 3 4 5 6 7 ON Main DIP Switch Settings (MODES) DIP Switch #1 - Soft Start/Stop The Soft Start/Stop feature slowly starts the gate as it begins to open and slows the gate as it comes to the closed position. This saves wear and tear on the gate and gate opener system. DIP Switch #2 - Warning Buzzer The Warning Buzzer alerts you when the gate opener is beginning to either open or close the gate. It sounds for the first 2 seconds in each direction. It also sounds a warning when the gate obstructs two times in one cycle. Switching this to OFF only disables the open and close warning not the obstruction warning. DIP Switch #3 - Auto-Close With the Auto-Close switch in the OFF position the gate will remain open until it receives another signal from an activation device such as a transmitter, keypad, or push button control. [. . . ] radius of detection of vehicles in motion. Automatic Gate Lock Pull-to-Open (FM144) A MUST for added security. Unlocks and locks automatically as gates open and close. Used with GTO/PRO® DC swing gate operating systems for maximum stability and security. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GTO PRO-SW 25502502

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GTO PRO-SW 25502502 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag