User manual GTO PRO-SW 6100

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GTO PRO-SW 6100. We hope that this GTO PRO-SW 6100 user guide will be useful to you.

Lastmanuals help download the user guide GTO PRO-SW 6100.


Mode d'emploi GTO PRO-SW 6100
Download
Manual abstract: user guide GTO PRO-SW 6100

Detailed instructions for use are in the User's Guide.

[. . . ] INSTALLATION INSTRUCTIONS FOR GTO/PRO SW-5100 and GTO/PRO SW-6100 AC Powered Swing Gate Operators LI US STED WARNING! · READ ALL INSTRUCTIONS COMPLETELY before attempting installation and use; failure to do so may result in serious injury or death!· This unit must only be installed by an experienced technician!Contact with gate operator circuitry can cause serious injury or death!Operator power must be disconnected before servicing! [. . . ] The system accessories should also be connected to the control board. Left Limit Nut OPEN position stop ­ if operator is mounted to the LEFT of the gate. CLOSED position stop ­ if operator is mounted to the RIGHT of the gate. Limit Switch Right Limit Nut CLOSED position stop ­ if operator is mounted to the LEFT of the gate. OPEN position stop ­ if operator is mounted to the RIGHT of the gate. Limit Switch Limit Switch Plate Travel Shaft The closer the limit nut is to the limit switch, the less distance the gate will travel to open or close. 15 ADVANCED GATE OPERATOR CONTROL BOARD T1SEC JP1 JP2 +300VDC DUAL GATE INTERFACE ­ + ­ STATUS LED RX + 24VDC ACCES. PWR. AUX 2 AUX 1 LOCK 2 LOCK 1 ­ TX + QC1 QC2 GRN GTO RED RCVR. BLK BATT1 EDGE 6 EDGE 5 EDGE 4 (Not Actual Size) BATT­ BATT TEMP EDGE 3 LEARN/RESET CLS. SENS. F1 Replace with 1/2 Amp Max PWR OK TIMER ON OBSTRUCT MIN MAX EDGE 2 EDGE 1 T1-P-CT OPN. SENS. COM COM BATT+ CLOSE MAX TIME SENSOR ERR. LIM SW ERR. MIN MAX OPEN INERTIA TIMER FIRE DEPT. GTO MODEM 1 2 3 4 5 OPEN MTR. LOOP COMPUTER RS-232 BATT SW 24AC 24CT 24AC SWNG/SLD MAST/SLV GATE R/L SEQUENC 1 SEQUENCE 2 TMR. OFF/ON NORM/LEARN COMP/MODEM 6 7 8 ENTRY ENAB ON ENTRY LOOP FREE EXIT CYCLE GTO Inc. , Tallahassee, FL 16 CONTROL BOARD SETTINGS LEARN/RESET: THESE SETTINGS SHOULD BE ADJUSTED ONLY BY AN EXPERIENCED INSTALLER OR TECHNICIAN! 1) Use to set transmitter code in control board memory. 2) Press this button to clear the diagnostic and error LEDs. LEARN/RESET ON SWNG/SLD MAST/SLV GATE R/L SEQUENC 1 SEQUENCE 2 TMR. OFF/ON NORM/LEARN COMP/MODEM GTO Inc. , Tallahassee, FL SWNG/SLD (swing or slide gate operation): SWNG = swing gate SLD = slide gate [factory default is SWNG]. MAST/SLV (master or slave unit): This DIP switch must be set to MAST for single gate applications. For dual gate applications set one control board to MAST and the other to SLD [factory default is MAST]. See installing a Dual System on pages 24-25. GATE R/L (gate opens right or left): The direction a gate opens is determined by standing inside the property and facing toward the gate. Set the DIP switch to R for a gate that opens to the right. Set the DIP switch to L for a gate that opens to the left. SEQUENCE 1: This DIP switch is used for sequencing swing gates [factory default is OFF]. For single gate applications this switch MUST be set to OFF. OFF/ON: (auto-close timer OFF or ON; close timer is set to 1 second at the factory): When this DIP switch is set to ON, the CLOSE TIMER potentiometer must be adjusted [factory default is OFF]. [. . . ] Products received at the factory without an RGA number will not be accepted. Replacement or repaired parts are covered by this warranty for the remainder of the warranty period or six (6) months, whichever is greater. GTO will pay shipping charges (equivalent to United Parcel Service ground rate) for return to owner of items repaired under warranty. The manufacturer will not be responsible for any charges or damages incurred in the removal of the defective parts for repair, or for the reinstallation of those parts after repair. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GTO PRO-SW 6100

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GTO PRO-SW 6100 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag