User manual HAIER AS09GS2ERA

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER AS09GS2ERA. We hope that this HAIER AS09GS2ERA user guide will be useful to you.

Lastmanuals help download the user guide HAIER AS09GS2ERA.


Mode d'emploi HAIER AS09GS2ERA
Download
Manual abstract: user guide HAIER AS09GS2ERA

Detailed instructions for use are in the User's Guide.

[. . . ] Please read this operation manual before using the air conditioner. Keep this operation manual for future reference. Please be subject to the actual produce purchased the above picture is just from your reference When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed and this room temperature is only for reference. Press the sleep button ten times in five seconds and enter function after hearing four sounds. [. . . ] Place, nearby a power receptacle, with enough space around. Place where the distance of more than lm from televisions, radios, wireless apparatuses and fluorescent lamps can be left. In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened. Attention must be paid to the rising up of drain hose The distance between the indoor unit and the floor should be more than 2m. Please be subject to the actual product purchased, the above picture is just for your reference. Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is first fixed 1. Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail. Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail. Find the wall hole location A using a measuring tape In case of left side piping, cut away, with a nipper, the lid for left piping. In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear piping which is marked on heat insulation materials. Insert the drain hose into the dent of heat insulation materials of indoor unit. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them. Coat the flaring seal face with refrigerant oil and connect pipes. Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape Indoor/outdoor electric cable and drain hose must be bound with efrigerant piping by protecting tape. Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according to theposition of wall hole. When bending, be careful not to crash pipes. Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulation of connecting part specially. Hang surely the unit body onto the upper notches of the mounting plate. Move the body from side to side to verify its secure fixing. In order to fix the body onto the mounting plate, hold up the body aslant from the underside and then put it down perpendicularly. When the mounting plate is fixed side bar and lintel Fix to side bar and lintel a mounting bar, Which is separately sold, and then fasten the plate to the fixed mounting bar. If wiring is not correct, proper operation can not be carried out and will cause defect. [. . . ] This is due to the sudden cooling of indoor air. In DRY mode, when room temperature becomes lower than temp. Setting+2 oC, unit will run intermittently at LOW speed regardless of FAN setting. Do not obstruct or cover the ventilation grille of the air conditoner. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER AS09GS2ERA

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER AS09GS2ERA will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag