User manual HAIER HPAC90E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HPAC90E. We hope that this HAIER HPAC90E user guide will be useful to you.

Lastmanuals help download the user guide HAIER HPAC90E.


Mode d'emploi HAIER HPAC90E
Download
Manual abstract: user guide HAIER HPAC90E

Detailed instructions for use are in the User's Guide.

[. . . ] Date of Purchase: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dealer's Name:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dealers Address: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dealers Phone Number: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TABLE RECEPTACLE RATED VOLTS AMPS 15 125/60 20 15 AND FUSE TYPES 250/60 20 30 WALL OUTLET FUSE SIZE TIME DELAY FUSE (or circuit braker) 15 Plug 20* Plug 15 20* Plug 30 (1) English SAFETY PRECAUTIONS WARNING: Following these basic precautions will reduce the risk of fire, electrical shock, injury or death when using your air conditioner. 1) Air conditioner must be connected to proper electrical outlet with the correct electrical supply. [. . . ] Extend hose to desired length and connect with window kit. Insert ends of Exhaust hose into air outlet nozzle and Exhaust duct "A" by twisting until it stops. Fix the Exhaust duct "A" to the exhaust outlet on the rear of the unit. This is achieved by sliding the appropriate connector downwards over the exhaust outlet ensuring that the lugs on the outlet are engaged with the grooves on the connector. Extend the Exhaust hose and close the Window as far as possible trapping the air outlet nozzle. IN DOOR IN DOOR IN DOOR IN DOOR USING WINDOW PANEL KIT 1. Screws - 4 pieces 1 2 3 (6) English Operation 1. Wait 20 minutes before starting the unti to assure that the coolant has leveled off. Wait 3 minutes before restarting the unit after a normal shutdown so as to complete the compressor cycle. Use an 115 volt 20 amp outlet for the air conditioner. Do not use any other electrical appliances on this line or you may trip the fuse. Dedicate the electric line for the air conditioner alone. Do not place the air conditioner in direct sunlight or close to any heating appliances. Operate the unit on a flat surface only. Check the filter at least once a month in order to acheive highest cooling efficiency. If the unit is not being used for a long period of time, please remove the plug to drain pipe and drain out any condensed water. Product Specification Voltage and Frequency Input Power Cooling Capacity Moisture Removal (pints/hr) Coolant Timer Operating Temperature Range Unit Dimensions (WxDxH) (inches) Net Weight lbs. approximate 115V / 60Hz 950 W 9000 BTU 2. 60 R22 8 Hours 64. 4°F - 100°F 20 1/4 x 13 13/32 x 29 13/16 71. 5 lbs. (7) English Care and Cleaning Guide · Always unplug your air conditioner before cleaning. · Air filter needs to be cleaned at least once a month for your unit to operate at optimum efficiency. The filter can be slid out from the back by pulling on the tab. Remove the excess water from the filter by gently shaking the filter. This will remove dust and particles trapped in the filter. DO NOT use your air conditioner without the air filter in place. · To clean the cabinet DO NOT use harsh chemicals, abrasives, ammonia, chlorine, bleach, concentrated detergents, solvents or metal scouring pads. [. . . ] Haier will repair or replace (excluding labor costs) the sealed system and compressor (parts only) for an additional 4 year period. Contact your nearest Haier authorized Service Depot. For the name of the Service Depot nearest you, contact Haier at (877) 337-3639. All service must be performed, by an authorized Haier Service Depot. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HPAC90E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HPAC90E will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag