User manual HAIER HSU-09C12

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSU-09C12. We hope that this HAIER HSU-09C12 user guide will be useful to you.

Lastmanuals help download the user guide HAIER HSU-09C12.


Mode d'emploi HAIER HSU-09C12
Download

You may also download the following manuals related to this product:

   HAIER HSU-09C12 annexe 1 (1292 ko)

Manual abstract: user guide HAIER HSU-09C12

Detailed instructions for use are in the User's Guide.

[. . . ] Installation Manual of Room Air Conditioner Read this manual before installation Explain sufficiently the operating means to the user according to this manual. Necessary Tools for Installation 1. Driver 2. Hacksaw 3. Hole core drill 4. Spanner(17, 19 and 26mm) 5. Torque wrench(17mm, 22mm, 26mm) 6. Pipe cutter 7. Flaring tool 8. Knife 9. Nipper 10. Gas leakage detector or soap-and-water solution 11. Measuring tape 12. Reamer Drawing for the installation of indoor and outdoor units Accessory parts 1 2 3 Mounting plate Remote controller 1 2 1 1 6 4 1 1 4 Optional parts for piping Mark A B C D E F G Parts name Non-adhesive tape Adhesive tape Saddle(L. S) with screws Connecting electric cable for indoor and outdoor Drain hose Heating insulating material Piping hole cover mo re th an R-03 dry battery 10c m 4 5 6 7 8 9 10 more than 5cm No. Accessory parts Number of articles Drain hose 4X50 Steel nail, cement 4X25 Screw Plastic cap mo re th an 10c m Attention must be paid to the rising up of drain hose A Drain-elbow Cover Cushion Arrangement of piping directions Rear left Left Rear right Below Right mo re tha n1 0c m C mo re th an 10c m Pipe supporting plate 1 D E more than 60cm more than 15c m The marks from A to G in the figure are the parts numbers. The distance between the indoor unit and the floor should be more than 2m. No. 0010559435 280 140 415 140 140 500 140 113. 5 583 113. 5 Floor fixing dimensions of the outdoor unit (Unit:mm) HSU-09C12 HSU-12C12 HSU-09C13 HSU-12C13 HSU-09C03/Z1 HSU-12C03/Z1 Floor fixing dimensions of the outdoor unit (Unit:mm) Floor fixing dimensions of the outdoor unit (Unit:mm) HSU-18C13 HSU-18CK03 HSU-22C13 HSU-24C13 Fixing of outdoor unit Fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizontally. When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails or wires in consideration of earthquake and strong wind. If vibration may affect the house, fix the unit by attaching a vibration-proof mat. Indoor Unit Selection of Installation Place Outdoor Unit Place, robust not causing vibration, where the body can be supported sufficiently. [. . . ] Charge according to the following list. for 9k 12k 18k Piping length Additional amount 5m No need 7m 40g 10m 100g for 22k 24k Piping length Additional amount 5m No need 7m 120g 10m 300g Note: When extending piping, air inside piping shall be removed by using external refrigerant gas, charge according to the following list. Brand new outdoor unit is charged 50g or 80g(only for 22k and 24k unit) more refrigerant than regulated weight. Only for first installation, this extra 50g or 80g(only for 22k and 24k unit) can be used to purge air in pipes. During this procedure, 50g or 80g(only for 22k and 24k unit) refrigerant will be discharged in piping. (This must be strictly controlled within 90 and 10 sec. ) o 7 1. Power Source Installation The power source must be exclusively used for air conditioner. (Over I0A) In the case of installing an air conditioner in a moist place, please install an earth leakage breaker. For installation in other places, use a circuit breaker as far as possible. 2. Cutting and Flaring Work of Piping Pipe cutting is carried out with a pipe cutter and burs must be removed. After inserting the flare nut, flaring work is carried out. A Pipe diameter( Liquid side Liquid side Gas side Gas side Gas side 6. 35mm(1/4") 9. 52mm(3/8") 9. 52mm(3/8") 12. 7mm(1/2") 15. 88mm(5/8") ) Size A(mm) 0. 8~1. 5 1. 0~1. 8 1. 0~1. 8 1. 2~2. 0 1. 4~2. 2 Flare tooling die Correct Incorrect Lean Damage of flare Crack Partial Too outside 3. On Drainage Please install the drain hose so as to be downward slope without fail. Please don't do the drainage as shown below. Less than 5cm It becomes high midway. Al fijar la unidad a la superficie de la pared, el tejado o la parte superior del tejado, fijar un soporte de forma segura con clavos o cables para el caso de que se produzca un terremoto o rachas de viento muy fuertes. Si las vibraciones pueden afectar a la casa, fijar la unidad colocando una esterilla a prueba de vibraciones. Unidad Interior Selección de lugar de la instalación Unidad Exterior La zona deberá ser resistente, no provocar vibraciones, y ser suficientemente robusta para soportar la unidad. La zona no se verá afectada por el calor ni el vapor generados en las cercanías, y la entrada y la salida de la unidad no se verán perturbadas. La zona podrá drenarse con facilidad, y las tuberías puedan podrán conectarse con la unidad exterior. La zona será una en la que el aire frío pueda difundirse por toda una sala. La zona estará cerca de una toma de tensión, con suficiente espacio alrededor. La zona será una en la que se podrá mantener una distancia superior a 1 m de televisores, radios, aparatos inalámbricos y lámparas fluorescentes. En el caso de fijar el mando a distancia en una pared, la zona será una en la que la unidad interior podrá recibir señales cuando se enciendan las lámparas fluorescentes de la sala. La zona deberá estar lo más resguardada posible de la lluvia, de la luz solar directa y deberá estar suficientemente ventilada. La zona podrá soportar la unidad y no aumentará las vibraciones ni el ruido. La zona deberá ser una en la que el ruido y el viento emitido no provoquen perturbaciones a los vecinos. La zona será una en la que una distancia marcada esté disponible, tal como se ilustra en la figura anterior. Alimentación Antes de introducir el enchufe en la toma, verificar que no hay errores de tensión. La alimentación es la misma que la de la placa de características correspondiente. Instalar un circuito de bifurcación exclusivo. [. . . ] (3) Aflojar 90° (un cuarto de vuelta) la válvula de dos vías utilizando una llave hexagonal y luego de aproximadamente 10 segundos, ajustarla. El gas sale a través de la tuerca cónica en el tubo ancho. Si no hay emisión de gas, ajuste la tuerca cónica con la fuerza de torsión especificada. (4) Abrir las válvulas de dos vías y tres vías usando la fuerza de torsión especificada. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-09C12

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-09C12 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag