User manual HAIER HSU-09HVD03/R2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSU-09HVD03/R2. We hope that this HAIER HSU-09HVD03/R2 user guide will be useful to you.

Lastmanuals help download the user guide HAIER HSU-09HVD03/R2.


Mode d'emploi HAIER HSU-09HVD03/R2
Download

You may also download the following manuals related to this product:

   HAIER HSU-09HVD03/R2 annexe 1 (582 ko)
   HAIER HSU-09HVD03/R2 annexe 2 (838 ko)

Manual abstract: user guide HAIER HSU-09HVD03/R2

Detailed instructions for use are in the User's Guide.

[. . . ] Press it once again, lock will be canceled and lock condition display disappears. 3. LIGHT button Control the lightening and extinguishing of the indoor LED display board. FRESH AIR display Outdoor Unit 4. Ambient temp. display When receiving the remote control signal, display the set temperatrue and in the rest time the room temperature is displayed and this room temperature is only for reference. NOTE : The following functions and related displays are not available: 1 Loading of the battery 1 Remove the battery cover; 2 Load the batteries as illustrated. OUTLET INLET CONNECTING PIPING AND ELECTRICAL WIRING DRAIN HOSE Please be subject to the actual produce purchased the above picture is just from your reference Clock set Press CLOCK button, "AM" or "PM" flashes. Press or to set correct time. Each press will increase or decrease 1min. If the button is kept pressed, time will change quickly. [. . . ] Hints: After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function, when use TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one. According to the Time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or Stop-Start can be achieved. WEEE In accordance with the directive 2002/96/CE of the European parliament, herewith we inform the consumer about the disposal requirements of the electrical and electronic products. DISPOSAL REQUIREMENTS: Your air conditioning product is marked with this symbol. This means that electrical and electronic products shall not be mixed with unsorted household waste. Do not try to dismantle the system yourself : the dismantling of the air conditioning system, treatment of the refrigerant, of oil and of other part must be done by a qualified installer in accordance with relevant local and national legislation. Air conditioners must be treated at a specialized treatment facility for reuse, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and humen health. Please contact the installer or local authority for more information. Battery must be removed from the remote controller and disposed of separately in accordance with relevant local and nationl legislation. Health airflow Operation 1. Press ON/OFF to starting Setting the comfort work conditions. 2. The setting of health airflow function appears on the 1). Press the button of health airflow , display. Avoid the strong airflow blows direct to the body. 2). Press the button of health airflow again, appears on Downward airflow sending. 3. The cancel of the health airflow function Press the button of health airflow again, the unit goes on working under the condition before the setting of health airflow function. Hot water over 40 O C(104O F) may cause discoloring or deformation. During cooling operation prevent the penetration of direct sunlight with curtain or blind Air Filter cleaning Open the inlet grille by pulling it upward. Remove the filter. Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward. If the unit is not to be used for a long time, turn off the power supply main switch. Use the louvers effectively Clean the filter. Use a vacuum cleaner to remove dust, or wash the filter with water. After washing, dry the filter completely in the shade. Attach the filter. Attach the filter correctly so that the "FRONT" indication is facing to the front. Make sure that the filter is completely fixed behind the stopper. If the right and left filters are not attached correctly, that may cause defects. OFF Once every two weeks Close the inlet grille. Replacement of Air Purifying Filter 1. Open the lnlet Grille Prop up the inlet grille by using a small device named grille-support which located in the right side of the indoor unit. The green aspect of the bacteria-killing medium air purifying filter will face outside, the white aspect will face to the machine. Note: the bacteria-killing mediums placed on the left side. The multi-lights touching intermediary is placed on the right side. 5. Close the Inlet Grille 2. Detach the standard air filter Slide the knob slightly upward to release the filter, then withdraw it. Close the Grille surely Common sense: 1. For the units with UV light degerming function, the air purifying filter of the bacteria-killing medium and the multi-lights touching intermediary is effective for a long time and don't need to be changed(UV light emitted by the UV light device of the indoor unit catalytically activates the nano TiO2 on the multi-lights touching intermediary, and the degerming effect is highly efficient and lasting. Multi-lights touching intermediary don't need to be exposed to be sunlight). 2. For the units without UV light degerming function, the air purifying filter of the multi-lights touching intermediary will be solarized in fixed time. In normal family, it will be solarized every 6 months. The solarization time will last no less than 8 hours under the state of abundant sun. 3. But in the use, please note to clean the filter frequently( take off the back suction cleaner or lightly pat it) to avoid the operating effect is lowered due to the dust covering the filter. Multi-lights touching intermediary and bacteria-killing medium filter is strictly prohibited from being cleaned by water. [. . . ] A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm. 11 . The power plug and connecting cable must have acquired the local attestation. 12. In order to protect the units, please turn off the A/C first, and at least 30 seconds later, cutting off the power. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-09HVD03/R2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-09HVD03/R2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag