User manual HAIER HSU-12HVA104-R2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSU-12HVA104-R2. We hope that this HAIER HSU-12HVA104-R2 user guide will be useful to you.

Lastmanuals help download the user guide HAIER HSU-12HVA104-R2.


Mode d'emploi HAIER HSU-12HVA104-R2
Download
Manual abstract: user guide HAIER HSU-12HVA104-R2

Detailed instructions for use are in the User's Guide.

[. . . ] Place, possible to bear the unit, where vibration and noise are not increased. Place, where discharged wind and noise do not cause a nuisance to the neighbors. Place, where a distance marked is available as illustrated in the above figure. Power Source Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate. [. . . ] In order to fix the body onto the mounting plate, hold up the body aslant from the underside and then put it down perpendicularly. 4. Connecting the indoor/outdoor Electric Cable Removing the wiring cover Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws. When connecting the cable after installing the indoor unit 1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed. Pull out the cable on the front side, and connect the cable making a loop. 4 Indoor unit When connecting the cable before installing the indoor unit Insert the cable from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover. Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F. -mod 07-09-12: 4G1. 5mm2 -mod 18: 3G2. 5mm2+1x0. 75mm2 -mod 22: 4G0. 75mm2 2. If the fuse on PC board is broken please change it with the type of T. The wiring method should be in line with the local wiring standard. After installation, the power plug should be easily reached. L Indoor unit Outdoor unit Indoor unit { POWER PLUG N HSU-07HV03/R2(DB) HSU-09HV03/R2(DB) HSU-12HV03/R2(DB) HSU-18HV03/R2(DB) HSU-12HVB03/R2(DB) HSU-09HVA104/R2(DB) HSU-12HVA104/R2(DB) HSU-22HV03/R2(DB) Outdoor unit Power cable: -mod 07-09-12: 3G1. 5mm2 -mod 18-22: 3G2. 5mm2 claw of the clip 5. Easily-demount cleaning of indoor unit 1. Top inlet can be taken down Open the inlet grille, press the claw of the clip on the unit, then take down the top inlet. (according to figure 1) 2. Vertical flap can be taken down Overturn the vertical flap, press the claw of the clip , then take down vertical flap. (according to figure 2) 3. Horizontal louvers can be taken down After taking down vertical flap. Horizontal louvers are appeared, draw the middle louver, and take down the horizontal louvers . (according to figure 3) Figure 2 Figure 1 Figure 2 Daff Figure 3 5 Outdoor unit 1. Installation of Outdoor Unit Install according to Drawing for the installation of indoor and outdoor units 2. Connection of pipes To bend a pipe, give the roundness as large as possible not to crush the pipe , and the bending radius should be 30 to 40 mm or longer. Connecting the pipe of gas side first makes working easier. The connection pipe is specialized for R410A. The max vertical distance between the indoor unit and the outdoor unit is 5 m. Half union Flare nut Forced fastening without careful centering may damage the threads and cause a leakage of gas. Pipe Diameter ( ) Fastening torque 18N. m 40N. m 55N. m Liquid side 6. 35mm(1/4") Gas side 9. 52mm(3/8") Spanner Gas side 12. 7mm(1/2") Torque wrench Be careful that matters, such as wastes of sands, etc. If it is over 5m, the function of the unit will be affected. If the pipe has to be lengthened, the refrigerant should be charged, according to 20 g/m. But the charge of refrigerant must be conducted by professional air conditioner engineer. [. . . ] 6 If it does not stop gas leakage, discharge whole refrigerants from the service port. After flaring work again and vacuumize, fill up prescribed refrigerant from the gas cylinder. 2-way valve 2-way valve 3-way valve 6 Detach the charge hose from the service port, open 2-way valve and 3-way. In case that the attached drain hose is in a room, please apply heat insulation to it without fail. Check for Installation and Test Run Please kindly explain to our customers how to operate through the instruction manual. Check Items for Test Run Gas leak from pipe connecting? [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-12HVA104-R2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-12HVA104-R2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag