User manual HAIER HSU-22LE03

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSU-22LE03. We hope that this HAIER HSU-22LE03 user guide will be useful to you.

Lastmanuals help download the user guide HAIER HSU-22LE03.


Mode d'emploi HAIER HSU-22LE03
Download

You may also download the following manuals related to this product:

   HAIER HSU-22LE03 annexe 1 (557 ko)

Manual abstract: user guide HAIER HSU-22LE03

Detailed instructions for use are in the User's Guide.

[. . . ] In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened. Place, which is less affected by rain or direct sunlight and is sufficiently ventilated. Place, possible to bear the unit, where vibration and noise are not increased. Place, where discharged wind and noise do not cause a nuisance to the neighbors. Place, where a distance marked is available as illustrated in the above figure. Power Source Before inserting power plug into receptacle, check the voltage without fail. [. . . ] Coat the flaring seal face with refrigerant oil and connect pipes. Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape Heat insulation material Lid for right piping Lid for under piping Lid for left piping Piping Drain hose Indoor/outdoor electric cable Fix with adhesive tape Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape. [Other direction piping] Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according to the position of wall hole. When bending, be careful not to crash pipes. Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulation of connecting part specially. Fixing the indoor unit body Hang surely the unit body onto the upper notches of the mounting plate. Move the body from side to side to verify its secure fixing. In order to fix the body onto the mounting plate, hold up the body aslant from the underside and then put it down perpendicularly. 4. Connecting the indoor/outdoor Electric Cable Removing the wiring cover Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws. When connecting the cable after installing the indoor unit 1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed. Pull out the cable on the front side, and connect the cable making a loop. 4 Indoor unit When connecting the cable before installing the indoor unit Insert the cable from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover. Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW). If the fuse on PC board is broken please change it with the type of T. The wiring method should be in line with the local wiring standard. After installation, the power plug should be easily reached. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm. 4 4 1(L) 2(N) Indoor unit Outdoor unit HSU-09LE03 HSU-09LD0307 HSU-12LE03 HSU-12LD0307 HSU-05LE03 HSU-12LE03-B HSU-07LE03 Indoor unit HSU-12LX03 Outdoor unit Connecting wiring: -mod 05-12: 3G1. 0mm2 -mod 18-22-24: 3G2. 5mm2 Power cable: -mod 05-12: 3G1. 0mm2 -mod 18: 3G1. 5mm2 -mod 22-24: 3G2. 5mm2 4 POWER PLUG Indoor unit { LN G N L Outdoor unit HSU-18LE03 HSU-18CK0307 HSU-22LE03 HSU-24CG0307 HSU-24LE03 HSU-18CK03 5 Outdoor unit Outdoor unit 1. Installation of Outdoor Unit Install according to Drawing for the installation of indoor and outdoor units 2. Connection of pipes To bend a pipe, give the roundness as large as possible not to crush the pipe Connecting the pipe of gas side first makes working easier. [. . . ] (5) Tighten the caps on the valves with specified torque. 2-way valve 6. 35mm(1/4") 3-way valve 12. 7mm(1/2") 15. 88mm(5/8") HSU-18LE03 HSU-18CK0307 HSU-22LE03 HSU-24CG0307 HSU-24LE03 HSU-18CK03 HSU-12LX03 2-way valve 6. 35mm(1/4") 3-way valve 9. 52mm(3/8") 12. 7mm(1/2") Tighten torque N. m Valve rod Valve cap 7-9 20-25 HSU-05LE03 HSU-09LD0307 HSU-07LE03 HSU-12LD0307 HSU-09LE03 HSU-12LE03-B HSU-12LE03 When connecting pipe exceeds 5 meters, 20g refrigerant shall be added per exceeding meter. Charge according to the following list. Piping length Additional amount 5m No need 7m 40g 10m 100g Note: When extending piping, air inside piping shall be removed by using external refrigerant gas, charge according to the following list. Brand new outdoor unit is charged 50g or 80g(only for 22k and 24k unit) more refrigerant than regulated weight. Only for first installation, this extra 50g or 80g(only for 22k and 24k unit) can be used to purge air in pipes. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-22LE03

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-22LE03 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag