User manual HAIER HUM07HC03-R2 INSTALLATION

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HUM07HC03-R2. We hope that this HAIER HUM07HC03-R2 user guide will be useful to you.

Lastmanuals help download the user guide HAIER HUM07HC03-R2.


Mode d'emploi HAIER HUM07HC03-R2
Download
Manual abstract: user guide HAIER HUM07HC03-R2INSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] A contains fluorinated greenhouse gases covered by the Kyoto Protocol B factory refrigerant charge of the product: see unit name plate C additional refrigerant amount charged in the field D total refrigerant charge E outdoor unit F refrigerant cylinder and manifold for charging Indoor/Outdoor Unit Installation Drawings The models adopt HFC free refrigerant R410A. For installation of the indoor units, refer to the installation manual which was provided with the units. (The diagram shows a wall-mounted indoor unit. ) Attention must be paid to the rising up of drain hose more than 15cm Optional parts for piping A Non-adhesive tape B Adhesive tape more than 10cm G C Saddle (L. S) with screws Connecting electric cable D for indoor and outdoor E Drain hose F Heating insulating material Arrangement of piping directions Rear left Left Rear right Right Below G Piping hole cover more than 10cm F A C more than 20cm more than 20cm Fixing of outdoor unit Fix the unit to concrete or block with bolts (10mm) and nuts firmly and horizontally. When fitting the unit to wall D E The marks from A to G in the figure are the parts numbers. [. . . ] R410A is a high-pressure refrigerant, and the use of the Do not use the following tools that have been used with the existing piping may result in bursting. Prepare tools that are for exclusive use with R410A. (Gauge manifold, charging hose, gas leak detector, reverse-flow check valve, refrigerant charge base, vacuum gauge, and refrigerant recovery equipment. ) If refrigerant and/or refrigerant oil left on these tools are Keep the inner and outer surfaces of the pipes clean and mixed in with R410, or if water is mixed with R410A, it will free of contaminants such as sulfur, oxides, dust/dirt shaving cause the refrigerant to deteriorate. Since R410A does not contain chlorine, gas-leak detectors Contaminants inside the refrigerant piping will cause the for conventional refrigerators will not work. Caution Store the piping to be used during installation indoors, and Do not use a charging cylinder. keep both ends of the piping sealed until immediately before The use of charging cylinder will change the composition brazing. (keep elbows and other joints wrapped in plastic. ) of the refrigerant and lead to power loss. If dust, dirt, or water enters the refrigerant cycle, it may cause the oil in the unit to deteriorate or may cause the compressor to malfunction. Exercise special care when handling the tools. An introduction of foreign objects such as dust, dirt or Use a small amount of ester oil, ether oil, or alkylbenzene water into the refrigerant cycle will cause the refrigerating to coat flares and flange connections. A large amount of mineral oil will cause the refrigerating machine oil to deteriorate. Use liquid refrigerant to charge the system. Charge the unit with gas refrigerant will cause the refrigerant Only use R410A refrigerant. in the cylinder to change its composition and will lead to The use of refrigerants containing chlorine(i. e. R22) will a drop in performance cause the refrigerant to deteriorate. Before Installing the Unit Caution Do not install the unit in a place where there is a possibility When installing the unit in a hospital, take necessary measures of flammable gas leak. Leaked gas accumulated around the unit may start a fire. High-frequency medical equipment may interfere with the normal operation of the air conditioning unit or the air Do not use the unit to preserve food, animals, plants, artifacts, conditioning unit may interfere with the normal operation or for other special purposes. of the medical equipment The unit is not designed to provide adepuate conditions to preserve the quality of these items. Do not use the unit in an unusual environment The use of the unit in the presence of a large amount of oil, steam, acid, alkaline solvents or special types of sprays Do not place the unit on or over things that may not get wet. may lead to a remarkable drop in performance and/or When humidity level exceeds 80% or when the drainage malfunction and presents a risk of electric shock, smoke, system is clogged, indoor units may drip water. Installation of a centralized drainage system for the outdoor The presence of organic solvents, corroded gas (such as unit may also need to be considered to prevent water drips ammonia, sulfur compounds, and acid may cause gas or from the outdoor units. water leak. ) 4 Safety Precautions Before Installing (Relocating) the Unit or Performing Electric Work Caution Ground the unit. Do not connect the grounding on the unit to gas pipes, water pipes, lightning rods, or the grounding terminals of telephones. [. . . ] The connection pipe is specialized for R410A. Half union Flare nut Forced fastening without careful centering may damage the threads and cause a leakage of gas. Pipe Diameter() Liquid side6. 35mm(1/4") Liquid/Gas side9. 52mm(3/8") Gas side 12. 7mm(1/2") Spanner Torque wrench Gas side 15. 88mm(5/8") Fastening torque 18N. m 42 N. m 55N. m 60 N. m Be careful that matters, such as wastes of sands, water, etc. , CAUTION The standard pipe length is C m. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HUM07HC03-R2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HUM07HC03-R2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag