User manual HAIER HUM12HA03-R2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HUM12HA03-R2. We hope that this HAIER HUM12HA03-R2 user guide will be useful to you.

Lastmanuals help download the user guide HAIER HUM12HA03-R2.


Mode d'emploi HAIER HUM12HA03-R2
Download
Manual abstract: user guide HAIER HUM12HA03-R2

Detailed instructions for use are in the User's Guide.

[. . . ] In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened. Place, which is less affected by rain or direct sunlight and is sufficiently ventilated. Place, possible to bear the unit, where vibration and noise are not increased. Place, where discharged wind and noise do not cause a nuisance to the neighbors. Place, where a distance marked is available as illustrated in the above figure. Power Source Before inserting power plug into receptacle, check the voltage without fail. [. . . ] Flare nut Forced fastening without careful centering Half union may damage the threads and cause a leakage of gas. Pipe Diameter ( ) Fastening torque 18N. m 40N. m 55N. m Liquid side 6. 35mm(1/4") Spanner Torque wrench Gas side 9. 52mm(3/8") Gas side 12. 7mm(1/2") Be careful that matters, such as wastes of sands, etc. If it is over 5m, the function of the unit will be affected. If the pipe has to be lengthened, the refrigerant should be charged, according to 20 g/m. But the charge of refrigerant must be conducted by professional air conditioner engineer. Before adding additional refrigerant, perform air purging from the refrigerant pipes and indoor unit using a vacuum pump, then charge additional refrigerant. Outdoor unit Outdoor unit A Oil trap Max. Length: A=20m(for: 09k 12k) A=25m(for:18k 22k) Indoor unit Indoor unit Max. Elevation: 10m (for: 09k 12k) 15m(for:18k 22k) CAUTION In case more than 5m Oil trap shoud be installed every 5~7m no more gas if the length of connecting pipe is less than10m 3. Connection Use the same method on indoor unit. Loosen the screws on terminal block and insert the plugs fully into terminal block, then tighten the screws. Insert the cable according to terminal number in the same manner as the indoor unit. If wiring is not correct, proper operation can not be carried out and controller may be damaged. Fix the cable with a clamp. 4. Attaching Drain-Elbow If the drain-elbow is used, please attach it as figure. (Note: Only for heat pump unit. ) 6 Outdoor unit 5. Purging Method:To use vacuum pump 2-way valve Liquid Side 6. 35mm(1/4") Gas Side 9. 52mm(3/8") 12. 7mm(1/2") 3-way valve Gaugemanifold(for R410A) Anti countercurrent joint Detach the service port's cap of 3-way valve, the valve rod's cap for 2-way valve and 3-way's, connect the service port into the projection of charge hose (low) for gaugemanifold. Then connect the projection of charge hose (center) for gaugemanifold into vacuum pump. Tube(for R410A) Vacuum pump(for R410A) Open the handle at low in gaugemanifold, operate vacuum pump. If the scale-moves of gause (low) reach vacuum condition in a moment, check again. Open Vacuumize for over 15min. And check the level gauge which should read -0. 1 MPa (-76 cm Hg) at low pressure side. After the completion of vacuumizing, close the handle 'Lo' in gaugemanifold and stop the operation of the vacuum pump. Check the condition of the scale and hold it for 1-2min. If the scale-moves back in spite of tightening, make flaring work again, the return to the beginning of . Close Open the valve rod for the 2-way valve to an angle of anticlockwise 90 degrees. After 6 seconds, close the 2-way valve and make the inspection of gas leakage. 2-way valve 90 Open o 6. 35mm(1/4") 3-way valve Service port 90ofor 6 sec. Liquid Side 9. 52mm(3/8") 12. 7mm(1/2") 3-way valve Gas Side 2-way valve In case of gas leakage, tighten No gas leakage?Detach the charge hose from the service port, open 2-way valve and 3-way. Turn the valve rod anticlockwise until hitting lightly. If it does not stop gas leakage, discharge whole refrigerants from the service port. [. . . ] A B C D E F contains fluorinated greenhouse gases covered by the Kyoto Protocol factory refrigerant charge of the product: see unit name plate additional refrigerant amount charged in the field total refrigerant charge outdoor unit refrigerant cylinder and manifold for charging This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Refrigerant type: R410A GWP* value: 1975 *GWP = global warming potential Please fill in with indelible ink, ·1 the factory refrigerant charge of the product ·2 the additional refrigerant amount charged in the field and · 1+2 the total refrigerant charge on the refrigerant charge label supplied with the product. FR INFORMATION IMPORTANTE RELATIVE AU RÉFRIGÉRANT UTILISÉ L'étiquette complétée doit être apposée à proximité de l'orifice de recharge du produit (par ex. à l'intérieur du couvercle de la vanne d'arrêt). A B C D E F contient des gaz à effet de serre fluorés encadrés par le protocole de Kyoto charge de réfrigérant d'usine du produit: voir plaquette signalétique de l'unité quantité de réfrigérant supplémentaire chargée sur place charge de réfrigérant totale unité extérieure cylindre de réfrigérant et collecteur de recharge Ce produit contient des gaz à effet de serre fluorés encadrés par le protocole de Kyoto. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HUM12HA03-R2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HUM12HA03-R2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag