User manual HANNA INSTRUMENTS BL 1.5

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS BL 1.5. We hope that this HANNA INSTRUMENTS BL 1.5 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS BL 1.5.


Mode d'emploi HANNA INSTRUMENTS BL 1.5
Download
Manual abstract: user guide HANNA INSTRUMENTS BL 1.5

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual BL1. 5 - BL3 - BL5 BL7 - BL10 BL15 - BL20 BL7913 - BL7914 Dosing Pumps These Pumps are in Compliance with the CE Directives http://www. hannainst. com Dear Customer, Thank you for choosing a Hanna product. Please read this instruction manual carefully before using the pump. This manual will provide you with the necessary information for a correct use of the pump, as well as a precise idea of its versatility. If you need more technical information, do not hesitate to e-mail us at tech@hannainst. com. [. . . ] self-priming height 1. 5 m (5') 0 to 50°C (32 to 122°F) 95% R. H. Dimensions for Installation BlackStone Pumps are designed for permanent installation. 18 19 The pump can be mounted directly on a wall or tank (see pages 12-17 for the specific mounting dimensions). Power Requirements BlackStone pumps are designed to operate to specifications within the following voltage ranges: 100 - 130 Volts for 115V models 200 - 240 Volts for 220V models To ensure maximum performance, check the voltage at the point of supply to verify that it is sufficient. It is recommended that you install a 1 Amp circuit breaker between the pump and the power supply. This will give additional protection to the internal circuit and provide a convenient way to disconnect the power supply prior to servicing the pump, if needed. Inside BL7913 and BL7914, for increased safety, the incoming voltage of either 115 or 240V is reduced to 12V by an isolated transformer. With a maximum voltage of 12V and with the transparent cover installed, risk of electrical problems is minimized. This makes the unit safer to operate with. · The ambient temperature of the pump, when in operation, should be between 0 and 50°C (32 to 122°F) and should be protected from direct exposure to outdoor elements (direct sunlight, rain, extreme temperatures, high humidity, etc. ). · Generally speaking, the shorter the suction distance, the more efficient the pump operates. · The pump should be placed in a conventional location that will allow easy access to the control and connections. It should be placed so that regular visual inspections of the connections and hoses are facilitated. Injection Point · Choose an injection point that allows you to mount the injection valve assembly vertically. · The spring in the injection valve assembly (HI 721004) adds approximately 1. 5 bar of back pressure. If pumping into a high back pressure, the spring should be removed. Other Considerations · If you are mounting the system to a wall, column, etc. , be sure it is strong enough to support the weight of the entire system. 20 Vertical Surface Mounting Once you have selected the best installation site, simply screw or bolt the unit into a wall or mounting panel above the chemical feed tank. The 4 mounting screw holes on the pump will accommodate up to a 5 mm (3/16") screw or bolt (remember to use heavy screws or bolts to secure the system). Be sure you do not over tighten and cause excessive stress on the mounting holes. For BL7913 and BL7914 Make sure to leave a slight overhang in front to allow for the connection cable. Electrical Connections Note: All cables must be according to local electrical codes. For safety of the users, the pump has to be grounded. For BlackStone Pumps: The pump should be connected to a single phase power source. 21 Color coding for wires: Blue - Live Brown - Neutral Yellow/Green - Ground (earth) · Remove the protective plastic plate covering the terminals by removing the 2 screws on both sides of the plate. Black Stone 40 30 20 10 0 50 60 70 80 90 100 FLOW % BL 7914 5 10 IP 54 WITH TRANSPARENT COVER INSTALLED 15 OVERHEATING 2 LITRES/HOUR BLUE BROWN YELLOW/ GREEN 0 110 220 115 240 It is recommended that the system be connected to a power line/leg equipped with a circuit breaker of 1 Amp. For BL7913 and BL7914: · Unscrew and remove the transparent front panel cover and gasket seal for access to the terminals. · Remove the cable gland from the hole on the housing below the power terminals (No. · Push a 3-wire power cord through the white gasketed fitting (inside the cable nut), leaving approximately 150mm (5") of cable to work with. · Feed the cord through the hole and connect the cable ends as indicated on the front panel, check the label on the front panel first and connect #1, 2, 4 for a 110V voltage or #1, 3, 4 for a 220V voltage, where: 0 110 115 Black Stone 40 30 20 10 0 50 60 70 80 90 100 FLOW % BL 7914 5 10 IP 54 WITH TRANSPARENT COVER INSTALLED 15 OVERHEATING 2 LITRES/HOUR 0 110 220 115 240 Black Stone 40 30 20 10 0 50 60 70 80 90 100 FLOW % BL 7914 5 10 IP 54 WITH TRANSPARENT COVER INSTALLED 15 OVERHEATING 2 LITRES/HOUR 0 is ground is neutral & 220 240 110 115 220 240 are the live 23 22 terminals. · Slide the fitting up, screw it onto the base and tighten the nut to form the watertight seal. · Replace the protective plastic cover. [. . . ] Replace if necessary with parts from HI 721102, HI 721103, HI 721104 and HI721105 (see page 40 for listing). When reinstalling the valves into the pumphead, tighten by hand first and then with a wrench ¼ to ½ turn. Inspecting the hose (if used as supplied with the pump) Inspect to see if the hose has worn out or weakened due to the chemicals. Pay particular attention for any signs of abrasion or discoloration. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS BL 1.5

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS BL 1.5 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag