User manual HANNA INSTRUMENTS HI 3898

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 3898. We hope that this HANNA INSTRUMENTS HI 3898 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 3898.


Mode d'emploi HANNA INSTRUMENTS HI 3898
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 3898

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual Significance and Use This screening test is a rapid test to detect high chloride levels in water and wastewater, that might cause interference with official COD methods. [. . . ] It will provide you with the necessary information for correct use of the kit. Remove the chemical test kit from the packing material and examine it carefully to make sure that no damage has SPECIFICATIONS occurred during shipping. If there is any noticeable damage, notify your Dealer or the nearest Hanna office immediately. Each kit is supplied with: · HI 3898-0 Reagent, 4 bottles (25 mL each); · Chloride Indicator, 1 dropper bottle (7 mL); · 1 glass cuvet with plastic stopper; · 2 calibrated syringes of 1. 0 ml with tip. Note: Any damaged or defective item must be returned in its original packing materials. SCREENING TEST PROCEDURE for COD - ISO Alternatively, use the 1. 0 ml graduated syringe with tip, to add 2. 0 ml of sample to the glass cuvet. Note: Note to dose exactly 2. 0 ml of sample to the cuvet, follow step (a) to step (e) twice: (a) push the plunger completely into the syringe, (b) insert tip into sample, (c) pull the plunger out until the lower edge of the plunger seal is on the 0 mL mark of the syringe, (d) take out the syringe and clean the outside of the syringe tip. Be sure that no drops are hanging on the tip of the syringe, if so eliminate them. (e) Then, keeping the syringe in vertical position above the cuvet, push the plunger completely down into the syringe. [. . . ] See also table 1. Specifications Range Analysis Method Sample Size Number of Tests Case Dimensions Shipping Weight 1000 ppm Cl- (ISO) 2000 ppm Cl- (EPA) screening test 2 mL 100 120 x 110 x 90 mm 200 g Table 1 · Cap the cuvet with the plastic stopper and shake vigorously to mix. ISTR3898R2 12/03 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 3898

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 3898 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag