User manual HANNA INSTRUMENTS HI 9624

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 9624. We hope that this HANNA INSTRUMENTS HI 9624 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 9624.


Mode d'emploi HANNA INSTRUMENTS HI 9624
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 9624

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual HI9624 - HI 9625 HI 96240 - HI 96250 Portable Waterproof GLP pH/°C Meters with Calibration Data Storage This instrument is in Compliance with the CE Directives H T T P : / / WWW. HANNAINST. COM 1 Dear Customer, Thank you for choosing a Hanna Instruments Product. Please read this instruction manual carefully before using the instrument. This manual will provide you with all the necessary information for the correct use of the instrument, as well as a precise idea of its versatility in a wide range of applications. These instruments are in compliance with the directives. [. . . ] This operation will display: · date DATE CAL CAL DATA · time CAL CAL DATA · the offset characteristic of the electrode in pH units pH CAL BUF 1 pH CAL DATA · the 1st slope in percentage of the theoretical value CAL pH BUF 2 CAL DATA · the 2nd slope in percentage of the theoretical value. CAL pH BUF CAL DATA 3 26 pH VALUES AT VARIOUS TEMPERATURE Temperature has an effect on pH. The calibration buffer solutions are effected by temperature changes to a lesser degree than normal solutions. During calibration the meter will automatically calibrate to the pH value corresponding to the measured temperature (if used in conjunction with the HI7669/2W temperature probe) or to the manually set temperature. TEMP °C °F 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 32 41 50 59 68 77 86 95 104 113 122 131 140 149 158 4. 01 4. 01 4. 00 4. 00 4. 00 4. 00 4. 01 4. 02 4. 03 4. 04 4. 05 4. 06 4. 07 4. 09 4. 11 4. 12 6. 86 6. 98 6. 95 6. 92 6. 90 6. 88 6. 86 6. 85 6. 84 6. 84 6. 83 6. 83 6. 84 6. 84 6. 85 6. 85 pH VALUES 7. 01 9. 18 7. 13 7. 10 7. 07 7. 04 7. 03 7. 01 7. 00 6. 99 6. 98 6. 98 6. 98 6. 98 6. 98 6. 99 6. 99 9. 46 9. 39 9. 33 9. 27 9. 22 9. 18 9. 14 9. 10 9. 07 9. 04 9. 01 8. 99 8. 97 8. 95 8. 93 10. 01 10. 32 10. 24 10. 18 10. 12 10. 06 10. 01 9. 96 9. 92 9. 88 9. 85 9. 82 9. 79 9. 77 9. 76 9. 75 For instance, if the buffer's temperature is 25°C, the display will show pH 4. 01 or 7. 01 or 10. 01. If the buffer's temperature is 20°C, the display will show pH 4. 00/7. 03/10. 06. If the buffer's temperature is 50°C, the display will show pH 4. 06/6. 98/9. 82. 27 TEMPERATURE AND mV CALIBRATION Each meter has been factory calibrated for the temperature and mV and is ready for measurements. The temperature probes and ORP electrodes are interchangeable and no temperature or mV calibration is needed when the temperature probe or the ORP electrode is replaced. If, for any reason, the temperature or the mV measurements are out of accuracy, the temperature or the mV re-calibration should be carried out. For an accurate recalibration, contact your nearest Hanna Service Center. 28 RS232C OUTPUT (HI96240 & HI96250) Connect the HI 96240 or the HI 96250 to a PC through the RS232C output (the connector is located on the top of the meter). SPECIFICATIONS: Baud Rate: Start bit: Stop bit: Parity bit: Command Prefix: Isolated 2400 1 1 none DLE SENDING COMMANDS FROM PC With terminal programs such as Telix® and Windows Terminal®, it is possible to remotely control your pH meter. Connect the meter to the PC, start the terminal program and set the communication options as follows: 8, N, 1, no flow control. Command Types To send a command to the pH meter the scheme is: <DLE> <command> <CR> The computer sends a Data Link Escape character, the command expressed as a number or a 3-character sequence) and a CR character. Note: Windows Terminal® and all other terminal programs that support the ANSI escape sequence, represent the DLE character by the string '^P' and the CR character by the string '^M'. the line '^PPHR^M' sets the range to pH. TELIX® is registered Trademark of "Deltacomm" Windows Terminal® are registered Trademark of "Microsoft Co. " 29 Commands not requiring an answer from the pH meter: PHR sets the range to pH MVR sets the range to mV (for HI 96250 only) Commands requiring an answer: PH?Causes the meter to send the pH value (6 characters). If the reading is out of range "Err 1" is sent. Causes the meter to send the mV value (5 or 6 characters). If the reading is out of range "Err 2" is sent. "-399. 9" + cr for -399. 9 mV "-1999" + cr for -1999 mV (for HI 96250 only) TM?Causes the meter to send the temperature value (6 characters). "100. 0" + cr for 100. 0°C CS?Requests the meter to send the pH calibration status (39 characters). The order of data is as follows: xx minutes (2 characters) xx hour (2 characters) xx day (2 characters) xx month (2 characters) xx year (2 characters) xxxxx offset buffer (5 characters) xxxxx offset factor (5 characters) xxxxx slope 1 buffer (5 characters) xxxx slope 1 factor (4 characters) xxxxx slope 2 buffer (5 characters) xxxx slope 2 factor (4 characters) x cr (1 characters) E. g. [. . . ] Use: very high humidity. 12 mm 0. 5" FC 911 110 mm 4. 3" HI 1413B / HI 1410S Glass-body, single junction, flat tip, Viscolene, combination pH electrode. Use: surface measurement. 12 mm 0. 5" HI 1413 110 mm 4. 3" Kynar® is registered Trademark of "Pennwalt Corp. " 46 Extension cables for screw-type electrodes only (screw to BNC connector) HI7855/1 HI7855/3 HI7855/5 HI7855/10 HI7855/15 Extension cable 1m (3. 3') long Extension cable 3m (9. 9') long Extension cable 5m (16. 5') long Extension cable 10m (33') long Extension cable 15m (49. 5') long HI 7855 SERIES CABLE CONNECTORS CONNECTOR AND 3. 0 mm (0. 12") CABLE WITH BNC CONNECT TO SCREW TYPE ELECTRODES CONNECT TO THE BNC SOCKET OF THE METER POWER UNITS HI710005 HI710006 Voltage adapter from 115 VAC to 12 VDC Voltage adapter from 230 VAC to 12 VDC 47 OTHER ACCESSORIES HI 710031 HI 721308 HI 76405 Rugged carrying case 1. 5V AA alkaline battery (10 pcs) Electrode holder HI 7669/2W HI 92000/16 Temperature probe with 1 m (3. 3') screened cable Windows® 3. 11 software for connection to PC (HI 96240 and HI 96250 only) Windows® 95 software for connection to PC (HI 96240 and HI 96250 only) 4 to 25-pin cable for connection to PC (HI 96240 and HI 96250) 4 to 9-pin cable for connection to PC (HI 96240 and HI 96250) pH and ORP electrode simulator with LCD display 1 m (3. 3') coaxial cable ending in female BNC connectors (HI 7858/1) Instruction manual HI 92000/32 HI 920011 HI 920011/9 HI 931001 MAN9624R1 Windows® is registered Trademark of "Microsoft Co. " 48 ELECTRODE APPLICATION REFERENCE GUIDE Application 1. Micro plate sampling of less than 100 mL 24. Titrations with constant temperature range 39. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 9624

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 9624 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag