User manual HANNA INSTRUMENTS HI 983327-0

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 983327-0. We hope that this HANNA INSTRUMENTS HI 983327-0 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 983327-0.


Mode d'emploi HANNA INSTRUMENTS HI 983327-0
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 983327-0

Detailed instructions for use are in the User's Guide.

[. . . ] Any defective item must be returned in its original packing. Trimmers CAL For calibration SET To adjust setpoint LEDs SET MEAS ALARM ON when LCD displays the set value ON when LCD displays the measured value ON when alarm contact is activated Front view of the panel-mounted unit Manufacturers since 1978 These Instruments are in Compliance with the CE Directives REAR PANEL 1. Power Supply: HI 983327-0 HI 98332700 12 VDC L1: L2: L3: L4: Note: HI 983327-1 115/230 VAC WARRANTY These meters are warranted for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. The probe is warranted for a period of six months. This warranty is limited to repair or replacement free of charge. [. . . ] Measurements are highly accurate and the meters can be calibrated at one point. Power supply, wiring and selection are made via the plugin terminal blocks on the rear panel. LED indicators on the front panel identify whether the controller is in set or measurement mode, and if alarm is active. Positive 230 VAC Negative 115 VAC ----Neutral ----Protection Earth the power input is internally protected by a 400 mA fuse Side view of the panel-mounted unit Supplied adjustable location brackets allow the controller to slide into the cutout and will hold the unit securely in place. 95 mm (3. 74") is the minimum amount of space required to install the controller. Panel-mounted unit assembling view 2. This contact acts as a switch for the power. The contact has to be protected outside by the user. Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. OPERATIONAL GUIDE POWER CONNECTION HI 983327-0 and HI 98332700 Connect a 2-wire power cable to the terminal strip while paying attention to the correct positive and negative contacts (12 VDC). HI 983327-1 Connect a 3-wire power cable to the terminal strip while paying attention to the correct earth, neutral and line contacts (115/230 VAC). Notes: · All external cables connected to the rear panel should end with wire lugs. · It is recommended to cover the unused terminals with insulating tape. · At start up the meter needs a few seconds to stabilize. Wait until a stable reading is displayed. ALARM CONTACT Use this contact (maximum 5A, 240VAC, 30VDC) for connection to an alarm or dosing system. The unit acts as a switch to control an external device. OPERATING THE METER All operations can be controlled via front panel keys and trimmers. "SET" and "MEAS" LEDs light up to indicate which is the operating function. Make sure that the meter is calibrated and the Setpoint is properly selected before performing any measurement. Install the probe in the fittings or immerse it in the solution to be monitored, while making sure that metal pins are completely submerged. The LCD will show the conductivity value of the solution in mS/cm unit. Any initial variation on readings may be due to temperature compensation. The "ALARM" LED will light up when the alarm contact is losed, to indicate an EC value higher than selected setpoint. [. . . ] 5A, 240 VAC, 30 VDC HI 7632-00 EC probe Automatic from 5 to 50°C (41 to 122°F); ß=2%/ºC Manual, at one point through trimmer Probe Temp. Compensation Calibration Calibration Solution H I 7039 (5. 00 mS/cm) Power supply: External HI 983327-0 12VDC HI 98332700 12VDC isolated inside with DC/DC converter HI 983327-1 115/230 VAC; 50/60Hz Dimensions 79 x 49 x 95 mm (3. 1 x 1. 9 x 3. 7") Weight: HI 983327-0, HI 98332700 140 g (4. 96 oz) HI 983327-1 250 g (8. 85 oz) Recommendations for Users Before using these products, make sure that they are entirely suitable for the environment in which they are used. Operation of these instruments in residential areas could cause unacceptable interferences to radio and TV equipment. The metal band at the end of the probe is sensitive to electrostatic discharges. Avoid touching this metal band at all times. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 983327-0

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 983327-0 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag