User manual HANNA INSTRUMENTS HI 122

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 122. We hope that this HANNA INSTRUMENTS HI 122 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 122.


Mode d'emploi HANNA INSTRUMENTS HI 122
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 122

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual HI 120 & HI 122 pH/mV/Temperature Bench Meters with Calibration Check ON OFF HI 122 pH / mV Meter CAL CFM CLR LOG Calibration Check w w w. c o m 1 Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction manual carefully before using the instruments. This manual will provide you with the necessary information for correct use of the instruments, as well as a precise idea of their versatility. [. . . ] The first pH calibration buffer: The second pH calibration buffer: The third pH calibration buffer: 24 The fourth pH calibration buffer: The fifth pH calibration buffer: Notes: · The "OLd" message displayed beside the pH value means that this buffer was not used during last calibration. Press 2nd then SET key if you want to see calibration date (or time, if old calibration was performed in the same day with current calibration). · Each calibration buffer is displayed with the resolution from calibration moment. · If "no bUF" message appears on the LCD, the instrument informs you that calibration was performed in less than five points. · The Calibration Alarm Time Out status. If disabled, or the number of days until the calibration alarm will be displayed (e. g. 5 days), or from the time calibration expired (e. g. · The instrument ID. 25 LAST RELATIVE mV CALIBRATION DATA Last Relative mV calibration data is stored automatically after a successful calibration. To view the Relative mV calibration data, press 2nd then GLP key or simply GLP from the left keyboard (HI 120) while in Relative mV measurement mode. The instrument will display the Relative mV GLP information. · The date (yyyy. mm. dd) of the last calibration as in pH GLP mode. Press the ARROW keys to view the next logged calibration parameter (pressing the key): · The Relative mV calibration offset and time (hh:mm) as in pH GLP mode. · The instrument ID as in pH GLP mode. Notes: · Press 2nd then GLP key at any moment and the instrument will return to measurement mode. · If calibration has not been performed, the instrument displays "no CAL" message blinking. 26 SETUP Setup mode allows viewing and modifying the following parameters: · Calibration Alarm Time Out · One-point calibration behaviour · Custom Buffer 1 · Custom Buffer 2 · Alarm High Limit · Alarm Low Limit · AutoLOG Start Condition · AutoLOG End Condition · AutoLOG Interval · Temperature Unit · Current Date (yyyy. mm. dd) · Current Time (hh:mm) · Printing Language (HI 122 only) · Printer Status (HI 122 only) · Beep Status · Baud Rate (serial communication) · Command prefix (serial communication) · Instrument ID To enter SETUP mode, press 2nd then SET key, or simply SET from the left keyboard (HI 120 only), while the instrument is in measurement mode. Select the desired setup parameter using the ARROW keys. Press CAL if you want to change the item value. hour, in setting up the correct time) and "CFM" tag will start blinking. Press the ARROW keys to change the displayed value or simply use the numerical keys for all numerical parameters. Note: To use the numerical keys, press NUM from the left keyboard. The new introduced digit is always the last one. All the previous digits will shift to left. Last introduced digit will be deleted and the number will shift to right. [. . . ] OTHER ACCESSORIES HI 710005 Voltage adapter from 115 VAC to 12 VDC (USA plug) HI 710006 Voltage adapter from 230 VAC to 12 VDC (European plug) HI 710012 Voltage adapter from 240 VAC to 12 VDC (UK plug) HI 710013 Voltage adapter from 230 VAC to 12 VDC (South African plug) HI 710014 Voltage adapter from 230 VAC to 12 VDC (Australian plug) HI 8427 pH and ORP electrode simulator with 1 m (3. 3') coaxial cable ending in female BNC connectors HI 931001 pH and ORP electrode simulator with LCD and 1 m (3. 3') coaxial cable ending in female BNC connectors HI 7662-T Temperature probe with 1 m (3. 3') cable HI 710032 Pack of 10 plain paper spare rolls (HI 122) HI 710033 Replacement ink cartridge (HI 122) HI 740157 Plastic electrode refilling pipet (20 pcs) HI 92000 Windows® compatible software HI 920010 9 to 9-pin RS232 cable 54 RECOMMENDATIONS FOR USERS Before using these products, make sure they are entirely suitable for the environment in which they are used. Operation of these instruments in residential areas could cause unacceptable interferences to radio and TV equipment, requiring the operator to follow all necessary steps to correct interferences. The glass bulb at the end of the pH electrode is sensitive to electrostatic discharges. Avoid touching this glass bulb at all times. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 122

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 122 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag