User manual HANNA INSTRUMENTS HI 4004

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 4004. We hope that this HANNA INSTRUMENTS HI 4004 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 4004.


Mode d'emploi HANNA INSTRUMENTS HI 4004
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 4004

Detailed instructions for use are in the User's Guide.

[. . . ] HI 4104 CALCIUM COMBINATION HI 4000-50 SENSOR HANDLE Instruction Manual HI 4004 HI 4104 Calcium Ion Selective Electrode Half-cell Combination 1 HI 4004 Calcium Half-cell HI 4104 Calcium Combination Electrode I. Introduction: The Hanna HI 4004 and HI 4104 are ion selective electrodes designed for the measurement of calcium ions in aqueous solutions. They utilize a replaceable sensing module that contains an organic polymer membrane that is sensitive to calcium ions. The HI 4004 is a half-cell electrode that requires a separate reference. [. . . ] Soak the Calcium electrodes membrane in HI 4004-45 conditioning solution or a calcium standard (0. 01M) without ISA before calibration. HI 4104 The Hanna HI 4104 is shipped disassembled. The sensing module is found in the glass storage vial. Unwrap Parafilm® seal found over ceramic junction on inner stem and discard. This is only used for shipping or long term storage. Do not touch the sensing membrane with the "H" hole pattern on it. Screw the cone into the inner stem finger tight. Do not over tighten. 8 Deionized Water Remove Parafilm Install sensing module 4. Rinse inner stem with deionized water making certain to wet o-ring found on the inner stem. Reassemble electrode by gently pushing the inner assembly into the outer body, sliding spring down cable, and screwing cap into place. Remove fill hole cover and o-ring on fill hole spout. Using the dropper pipette provided, add a few drops HI 7082 fill solution to the electrode. Invert the electrode to wet the o-ring and rinse the fill solution chamber. 9 7. Holding the body of the electrode gently press upper cap with your thumb. This permits the fill solution to drain out of the body. Release cap and verify electrode returns to its original position. (You may need to gently assist for this to occur). 8. Tighten the electrode cap onto the body and fill electrode body until fill solution volume is just below fill hole. Position electrode in a Hanna HI 76404 electrode holder (or equivalent) and connect BNC connector to meter. · · · Quick Check of Electrode Slope Connect electrode(s) to pH/mV/ISE meter Place meter in mV mode. Place 100 mL of deionized water into a beaker with stir bar. · Place reference and measuring half-cell or combination electrode into prepared sample. [. . . ] Standards should bracket and fall within the range of interest. Standards and solutions should be at the same temperature. 2) 2 mL of HI 4004-00 is added to 100 mL of both samples and standards. Add stir bar and mix before taking measurements. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 4004

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 4004 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag