User manual HANNA INSTRUMENTS HI 4102

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 4102. We hope that this HANNA INSTRUMENTS HI 4102 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 4102.


Mode d'emploi HANNA INSTRUMENTS HI 4102
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 4102

Detailed instructions for use are in the User's Guide.

[. . . ] HI 4102 BROMIDE COMBINATION HI 4002 Instruction Manual HI 4002 HI 4102 Bromide Ion Selective Electrode Half-cell Combination 1 BROMIDE HI 4002 Bromide Half-cell HI 4102 Bromide Combination Electrode I. Introduction: The Hanna HI 4002and HI 4102 are ion selective electrodes designed for the measurement of Bromide ions in aqueous solutions. The HI 4002 is a solid state half-cell sensor that requires a separate reference. The HI 4102 is a combination ion selective electrode. [. . . ] Excessive loss (>4 cm drop within 24 hours) is not normal. If this occurs verify cap is tightened and the interface between the internal cone and outer body is free of debris. · Add fill solution daily to maintain a good head pressure. For optimum response, this level should be maintained and not be allowed to drop more than 2-3 cm (1-inch) below fill hole. It must cover the ceramic found on the inner stem. · If an erratic measurement occurs, check to see if foreign matter is seen trapped near the internal cone. Drain and refill with fresh fill solution. 7 VIII. Remove protective cover from sensor tip. Prepare reference electrode by filling outer electrolyte reservoir with HI 7072. Place sensor and reference electrodes into electrode holder and connect cable connectors to meter. Unwrap plastic film seal found over ceramic junction on inner stem and discard. This is only used for shipping and long term storage. Rinse inner stem with deionized water making certain to wet the o-ring found on the inner stem. Deionized Water Remove Parafilm 3. Reassemble electrode by gently pushing the inner assembly into the outer body, sliding spring down cable, and screwing cap into place. Remove fill hole cover and o-ring on fill hole spout. Using the dropper pipette provided, add a few drops HI 7072 fill solution to the electrode, wetting the oring and rinsing out the fill solution chamber. 8 6. Holding the body of the electrode gently press upper cap with your thumb. This permits the fill solution to drain out of the body. Release cap and verify electrode returns to its original position. (You may need to gently assist for this to occur). 7. Tighten the electrode cap onto the body and fill electrode body until fill solution volume is just below fill hole. Position electrode in a Hanna HI 76404 electrode holder (or equivalent) and connect plug to meter. 9 HI 4102 E ID BROM ATION IN COMB IX. [. . . ] A pH/mV meter in mV mode with semi log graph paper may also be used. Two or more freshly prepared standards that are in the measurement range of the unknowns are measured in mV mode on the meter. These values are plotted on the semi-log paper and the points are connected to form a straight-line curve. When samples are measured, their mV values are converted to concentration by following the mV to the concentration axis on the semi-log plot. 11 1) 2) 3) 4) 5) Procedure Follow sections VIII and IX to prepare sensors for measurement. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 4102

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 4102 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag