User manual HANNA INSTRUMENTS HI 504901

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 504901. We hope that this HANNA INSTRUMENTS HI 504901 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 504901.


Mode d'emploi HANNA INSTRUMENTS HI 504901
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 504901

Detailed instructions for use are in the User's Guide.

[. . . ] HI 504901 GSM Supervisor Instruction Manual TABLE OF CONTENTS WARRANTY . 12 12 12 12 13 13 13 15 15 16 START-UP . Stick here the IMEI number label or write it down for your future reference. ________________________________________________________________ CONFIGURATION SETTINGS . [. . . ] Available alarm conditions for HI504 are: · Alarm for setpoint 1; · Alarm for setpoint 2; · Max relay ON time; · Life check error; · pH electrode broken; · Reference electrode broken; · Old pH probe; · Dead pH probe; · Calibration time-out; · Temperature probe broken; · Analog input; · EEPROM corruption; · Temperature level. Available alarm conditions for HI504910 are: · Life check error; · pH electrode broken; · Reference electrode broken; · Old pH probe; · Dead pH probe; · Temperature probe broken; · EEPROM corruption. Please refer to the HI504 Instruction Manual or HI504910 Instruction Manual for a complete explanation of the above alarm conditions. 32 Note Note Note open the digital output contact. If the digital output control is enabled, when an information will be requested to HI504901, an SMS with the digital output status will be sent. By disabling this option, it will not be possible to set the digital output status and no information SMS about the digital output will be sent. If the digital output management is disabled, the digital output will be automatically opened, even if it was previously closed. If the password is not set, only "CLOSEP" or "OPENP" SMS must be sent. SMS DELIVERY HI504901 is able to send SMSs to one (or two) cellular phone number(s). HI504901 can send two types of message: alarm SMSs (upon an alarm condition at least in one of the instruments connected to the interface) and information SMS (upon specific request from the user). To use the SMS feature, a SIM card able to make a voice call must be used. Alarm messages are submitted by HI504901 to the cellular phone number(s) when an error occurred on one of the instruments connected to the interface. A message about an alarm condition in one instrument will be sent by the interface only if the alarm is active and the specific alarm notification was enabled during last configuration, by checking the proper box on the "message option" window of the selected device (see "Interface configuration" section). If an alarm is active in one instrument connected to the interface but its notification was not enabled during last configuration, then no SMS will be sent (however HI504901 gives indication to the user about the error condition by turning on the red LED for the RS232 channel or RS485 port or digital input port where the instrument is connected). An alarm SMS can be sent only if SMS sending is user enabled through digital input terminal (#8 on page 8), otherwise no SMS will be issued. The format of alarm messages for instruments connected to the RS232 ports will be: "<INSTRUMENT NAME>; RS232-<NUMBER OF THE RS232 CHANNEL>; Alarms: <ALARM SPECIFIC TO THE INSTRUMENT>; Rem msg: <NUMBER OF REMAINING MESSAGES>" The format of alarm messages for instruments connected to the RS485 port will be: "<INSTRUMENT NAME>; RS485-<RS485 DEVICE ADDRESS>; Alarms: <ALARM SPECIFIC TO THE INSTRUMENT>; Rem msg: <NUMBER OF REMAINING MESSAGES>" During alarm condition, the field <ALARM SPECIFIC TO THE INSTRUMENT> on the alarm message will contain the list of 35 Note ALARM SMSs Default values The following table lists the default value for previous items, i. e. the factory values copy from ROM if HI504901 was never configured. Item Telephone #1 Telephone #2 Date Time Remaining SMSs Expiration date Repeated SMSs SMS delay Query delay Password PIN RS232 options RS485 options Digital input Digital output Default value empty field empty field from internal RTC from internal RTC disabled disabled 2 10 minutes 1 minute disabled empty field no instrument configured no instrument configured disabled disabled Note 34 only active alarms; when all active alarms can not be sent within one SMS (the maximum number of characters for an SMS is 160), more than one message will be sent, each one having as header the label "Alarms#p/#t:" with the indication of the progressive alarm SMS number (#p) and the total number of alarm SMSs (#t) that are going to be sent for the instrument. The <INSTRUMENT NAME> label is a text string correspondent to the instrument model with active alarm(s). The <NUMBER OF REMAINING MESSAGES> is a value (max. 4 digits) indicating the number of remaining messages in the SIM card (see "Interface configuration" section). Following a complete list of all available alarm indications (and their coded notations) for all devices which can communicate with HI504901 supervisor and some messages specific to HI504901 interface itself. Alarms for HI8001 and HI8002 controllers Coded notation for <INSTRUMENT NAME> label is "HI8001" or "HI8002" (depending on controller model), while coded notations for active alarms are: · "pHsensor": this alarm is triggered if the difference between the real time values of the two primary pH sensors exceed the specified maximum allowable difference. · "ECsensor": this alarm is triggered if the difference between the real time values of the two primary EC sensors exceed the specified maximum allowable difference. [. . . ] Solutions Change the SIM card with one enabled for voice calls. Note: Some SIM cards can be used both for data and voice calls. Please check the network operator for further details. 62 63 APPENDIX RS232 AUXILIARY PORT HI504901 is provided with an auxiliary RS232 port (D-Sub 9-pole female plug) for connection to a local PC using an HI920010 Hanna cable. If the provided HI920010 Hanna cable is too short for your application, it is possible to make a longer communication cable (up to 15 m long) by following the below table for pin connections. CE DECLARATION OF CONFORMITY PC side female connector pin 2 3 4 5 6 HI504901 side male connector pin 3 2 6 5 4 Recommendations for Users Before using this product, make sure that it is entirely suitable for the environment in which it is used. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 504901

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 504901 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag