User manual HANNA INSTRUMENTS HI 504903

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 504903. We hope that this HANNA INSTRUMENTS HI 504903 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 504903.


Mode d'emploi HANNA INSTRUMENTS HI 504903
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 504903

Detailed instructions for use are in the User's Guide.

[. . . ] HI 504903 GSM Supervisor Instruction Manual TABLE OF CONTENTS WARRANTY . 12 12 12 13 13 13 15 15 16 START-UP . Stick here the IMEI number label or write it down for your future reference. ________________________________________________________________ CONFIGURATION SETTINGS . [. . . ] · The alarm can be triggered upon the closing or opening of a contact on digital output (default trigger event is closed contact). The maximum length of this description is 30 characters. Digital output section It is possible to enable (or disable) the control of the digital output status connected to the HI504903 by checking the proper check-box. Once enabled, it is possible to control the digital output simply sending the SMS "CLOSEP<cellular phone interface password>" to close the digital output contact, and "OPENP<cellular phone interface password>" to open the digital output contact. If the digital output control is enabled, when an information will be requested to HI504903, an SMS with the digital output status will be sent. Note By disabling this option, it will not be possible to set the digital output status and no information SMS about the digital output will be sent. 30 Note Note If the digital output management is disabled, the digital output will be automatically opened, even if it was previously closed. If the password is not set, only "CLOSEP" or "OPENP" SMS must be sent. Default values The following table lists the default value for previous items, i. e. the factory values copy from ROM if HI504903 was never configured. Item Telephone #1 Telephone #2 Date Time Remaining SMSs Expiration date Repeated SMSs SMS delay Query delay Password PIN RS485 options Digital input Digital output Default value empty field empty field from internal RTC from internal RTC disabled disabled 2 10 minutes 1 minute disabled empty field no instrument configured disabled disabled 31 SMS DELIVERY HI504903 is able to send SMSs to one (or two) cellular phone number(s). HI504903 can send two types of message: alarm SMSs (upon an alarm condition at least in one of the instruments connected to the interface) and information SMS (upon specific request from the user). To use the SMS feature, a SIM card able to make a voice call must be used. Note ALARM SMSs Alarm messages are submitted by HI504903 to the cellular phone number(s) when an error occurred on one of the instruments connected to the interface. A message about an alarm condition in one instrument will be sent by the interface only if the alarm is active and the specific alarm notification was enabled during last configuration, by checking the proper box on the "message option" window of the selected device (see "Interface configuration" section). If an alarm is active in one instrument connected to the interface but its notification was not enabled during last configuration, then no SMS will be sent (however HI504903 gives indication to the user about the error condition by turning on the red LED for the RS485 port or digital input port where the instrument is connected). Note An alarm SMS can be sent only if SMS sending is user enabled through digital input terminal (#9 on page 8), otherwise no SMS will be issued. Alarm SMSs for HI142 dataloggers The format of alarm messages for HI142 dataloggers connected to the RS485 port will be: "HI142-SN<DEVICE SERIAL NUMBER>; LotlD<USER LOT ID>; Alarms: <ALARM SPECIFIC TO THE INSTRUMENT>; Rem msg: <NUMBER OF REMAINING MESSAGES>" During alarm condition, the field <ALARM SPECIFIC TO THE INSTRUMENT> on the alarm message contains the list of only active alarms (see further on for the complete list of selectable alarms). The <DEVICE SERIAL NUMBER> label is a 6-character text string with the serial number of the HI142 generating the alarm SMS. The <USER LOT ID> label is a label (up to 16 characters) with the user-defined lot identification: this is the identification lot 32 Note string that user can specify in HI92140 software before starting logging with HI142 (see "LotID" field in HI92140 software). The <NUMBER OF REMAINING MESSAGES> is a value (max. 4 digits) indicating the number of remaining messages in the SIM card (see "Interface configuration" section). The complete list of all available alarm indications (and their coded notations) for HI142 temperature datalogger is: · "Temperature": the temperature on HI142 logger exceeds low or high temperature limits. · "Low battery": the charge level of the logger battery is low and should be replaced soon; contact the nearest Hanna Service Center. [. . . ] Please check the network operator for further details. 54 55 APPENDIX SECTION 1: CONNECTING THE HI142 NETWORK TO HI504903 For connecting the first HI142 datalogger to the HI504903 interface, make a cable for both RS485 and power supply connections. A 4-wire cable and an RJ11 jack (male connector) are necessary, then follow the below diagram: SECTION 2: CONNECTING HI142 TO HI142 For connecting one HI142 datalogger to the next one, make a cable as explained on the below diagram, by using a 4wire cable and two RJ11 jacks (male connectors): SECTION 3: RS232 AUXILIARY PORT HI504903 is provided with an auxiliary RS232 port (D-Sub 9-pole female plug) for connection to a local PC using an HI920010 Hanna cable. If the provided HI920010 Hanna cable is too short for your application, it is possible to make a longer communication cable (up to 15 m long) by following the below table for pin connections. PC side female connector pin 2 3 4 5 6 HI504903 side male connector pin 3 2 6 5 4 56 57 CE DECLARATION OF CONFORMITY Recommendations for Users Before using this product, make sure that it is entirely suitable for the environment in which it is used. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 504903

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 504903 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag