User manual HANNA INSTRUMENTS HI 83210

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 83210. We hope that this HANNA INSTRUMENTS HI 83210 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 83210.


Mode d'emploi HANNA INSTRUMENTS HI 83210
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 83210

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual HI 83210 Multiparameter Bench Photometer for Pulp & Paper Mills www. hannainst. com 1 Dear Customer, Thank you for choosing a Hanna product. Please read this instruction manual carefully before using the instrument. This manual will provide you with the necessary information for the correct use of the instrument. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst. com. TABLE OF CONTENTS PRELIMINARY EXAMINATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] To read all the available information, scroll the text using the keys. Press the Support key to access a screen with Hanna service centers and their contact details. Press the Accessories key to access a list of instrument reagents and accessories. To exit support or accessories screens press ESC and the instrument will return to the previous help screen. To exit help mode press the HELP or ESC key again and the meter will return to the previously selected screen. 16 ALUMINUM SPECIFICATIONS Range Resolution Accuracy Typical EMC Deviation Light Source Method 0. 00 to 1. 00 mg/L 0. 01 mg/L ±0. 02 mg/L ±4% of reading at 25 °C ±0. 01 mg/L Tungsten lamp with narrow band interference filter @ 525 nm Adaptation of the aluminon method. The reaction between aluminum and reagents causes a reddish tint in the sample. Description Ascorbic acid Aluminon reagent Bleaching powder Quantity 1 packet 1 packet 1 packet REQUIRED REAGENTS Code HI 93712A-0 HI 93712B-0 HI 93712C-0 REAGENT SETS HI 93712-01 Reagents for 100 tests HI 93712-03 Reagents for 300 tests For other accessories see page 49. MEASUREMENT PROCEDURE · Select the Aluminum method using the procedure described in the Method Selection section (see page 12). · Fill a graduated beaker with 50 mL of sample. · Add the content of one packet of HI 93712A-0 Ascorbic acid and mix until completely dissolved. · Add the content of one packet of HI 93712B-0 Aluminon reagent and mix until completely dissolved. This is the sample. 10 mL · Fill two cuvettes with 10 mL of sample each (up to the mark). 10 mL #2 #1 17 Aluminum · Add the content of one packet of HI 93712C-0 Bleaching powder to one of the two cuvettes. Replace the cap and shake vigorously until completely dissolved. This is the blank. #1 · Place the blank into the holder and close the lid. · Press Timer and the display will show the countdown prior to zeroing the blank. Alternatively wait for 15 minutes and then press Zero. The display will show "-0. 0-" when the meter is zeroed and ready for measurement. #1 #2 · Remove the blank and insert the other cuvette into the instrument. · Press the Read key and the meter will perform the reading. The instrument displays the results in mg/L of aluminum. · Press or to access the second level functions. · Press the Chem Frm key to convert the result in mg/L of Al2O3. · Press or to return to the measurement screen. INTERFERENCES Interference may be caused by: Iron above 20 mg/L, Alkalinity above 1000 mg/L, Phosphate above 50 mg/L; Fluoride must be absent. Aluminum 18 FREE CHLORINE SPECIFICATIONS Range Resolution Accuracy Typical EMC Deviation Light Source Method 0. 00 to 2. 50 mg/L 0. 01 mg/L ±0. 03 mg/L ±3% of reading at 25 °C ±0. 01 mg/L Tungsten lamp with narrow band interference filter @ 525 nm Adaptation of the EPA DPD method 330. 5. The reaction between free chlorine and the DPD reagent causes a pink tint in the sample. REQUIRED REAGENTS POWDER: Code HI 93701-0 LIQUID: Code HI 93701A-F HI 93701B-F Description DPD Description DPD1 Indicator DPD1 Buffer Quantity 1 packet Quantity 3 drops 3 drops REAGENT SETS HI 93701-F Reagents for 300 tests (liquid) HI 93701-01 Reagents for 100 tests (powder) HI 93701-03 Reagents for 300 tests (powder) For other accessories see page 49. MEASUREMENT PROCEDURE · Select the Free Chlorine method using the procedure described in the Method Selection section (see page 12). 10 mL · Fill the cuvette with 10 mL of unreacted sample (up to the mark) and replace the cap. · Place the cuvette into the holder and close the lid. 19 Free Chlorine · Press the Zero key. The meter will show "-0. 0-" when the meter is zeroed and ready for measurement. · Remove the cuvette. Powder reagents procedure · Add the content of one packet of HI 93701 DPD reagent. Replace the cap and shake gently for 20 seconds (or 2 minutes for seawater analysis). · Reinsert the cuvette into the instrument. · Press Timer and the display will show the countdown prior to the measurement or, alternatively, wait for 1 minute and press Read. [. . . ] · Insert the sample into the instrument. · Press Timer and the display will show the countdown prior to the measurement or, alternatively, wait for 3 minutes and 30 seconds and press Read. When the timer ends the meter will perform the reading. · The instrument displays the results in mg/L of zinc. INTERFERENCES Interference may be caused by: Aluminum above 6 mg/L Cadmium above 0. 5 mg/L Copper above 5 mg/L Iron above 7 mg/L Manganese above 5 mg/L Nickel above 5 mg/L 45 Zinc ERRORS AND WARNINGS The instrument shows clear warning messages when erroneous conditions appear and when measured values are outside the expected range. No Light: The light source is not functioning properly. Light Leak: There is an excess amount of ambient light reaching the detector. Inverted cuvettes: The sample and the zero cuvettes are inverted. Battery Low: The battery capacity is lower than 10%. Light Low: The instrument cannot adjust the light level. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 83210

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 83210 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag