User manual HANNA INSTRUMENTS HI 96718C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 96718C. We hope that this HANNA INSTRUMENTS HI 96718C user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 96718C.


Mode d'emploi HANNA INSTRUMENTS HI 96718C
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 96718C

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual HI 96718C Iodine ISM www. hannainst. com 1 Dear Customer, Thank you for choosing a Hanna product. This manual will provide you with the necessary information for the correct use of the instrument. Please read it carefully before using the meter. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst. com. TABLE OF CONTENTS PRELIMINARY EXAMINATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · Calibration mode: may be entered by keeping CAL CHECK pressed for three seconds (the "CAL" tag appears), it enables calibration of the instrument. · GLP mode may be entered by pressing GLP/ ("GLP" appears), it enables consulting of user calibration date or restore factory calibration. DISPLAY ELEMENTS DESCRIPTION 5 4 3 9 2 1 10 6 7 8 1) The measuring scheme (lamp, cuvette, detector), appears during different phases of zero or reading measurement 2) Error messages and warnings 3) The battery icon shows the charging level of the battery 4) The hourglass appears when an internal checking is in progress 5) Status messages 6) The chronometer appears when the reaction timer is running 7) The month, day and date icons appear when a date is displayed 8) Four digit main display 9) Measuring units 10) Four digit secondary display 8 ERRORS AND WARNINGS The instrument shows clear messages when erroneous condition appears. Messages are also displayed when the obtained values are outside expected range. a) on zero reading Light High: There is too much light to perform a measurement. Please check the preparation of the zero cuvette. Light Low: There is not enough light to perform a measurement. Please check the preparation of the zero cuvette. No Light:The instrument cannot adjust the light level. Please check that the sample does not contain any debris. b) on sample reading Inverted cuvettes: The sample and the zero cuvette are inverted. Zero: A zero reading was not taken. Follow the instructions of the measurement procedure for zeroing the meter. 9 Under range: A blinking "0. 0" indicates that the sample absorbs less light than the zero reference. Check the procedure and make sure you use the same cuvette for reference (zero) and measurement. Over Range: A flashing value of the maximum concentration indicates an over range condition. As a general rule of thumb, they should be doubled at 10°C (50°F) and halved at 30°C (86°F). · In order to maximize accuracy, prior to a measurement follow the validation procedure to be sure that the instrument is properly calibrated. If necessary, calibrate the instrument. STARTUP Prepare the instrument for measurement as follows: · Unpack the instrument by removing the dust protection sleeve from the instrument cuvette holder. · Place the battery in the instrument as described in the "BATTERY REPLACEMENT" chapter. · Place the instrument on a flat table. · Do not place the instrument under direct sun light. MEASUREMENT PROCEDURE To compensate the meter for the sample turbidity or color, the measurement takes place in two phases. First, the meter is zeroed using the unreacted sample. After the reagents are added the reacted sample is measured. · Turn the meter on by pressing ON/OFF. The display briefly shows all tags on. 12 · When the beeper sounds briefly and the LCD displays dashes, the meter is ready. The blinking "ZERO" indicates that the instrument needs to be zeroed first. · Fill the cuvette with 10 mL of unreacted sample, up to the mark, and replace the cap. · Place the cuvette into the cuvette holder and ensure that the notch on the cap is positioned securely into the groove. · Press ZERO/CFM and the lamp, cuvette and detector icons will appear on the display, depending on the measurement phase. · After a few seconds, the display will show "-0. 0-". The meter is now zeroed and ready for measurement. 13 · Remove the cuvette. [. . . ] If a valid measurement was displayed before auto-shut off, the value is displayed when the instrument is switched on. The blinking "ZERO" means that a new zero has to be performed. One fresh battery lasts for around 750 measurements, depending on the light level. The remaining battery capacity is evaluated at the instrument startup and after each measurement. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 96718C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 96718C will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag