User manual HANNA INSTRUMENTS HI 96804

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 96804. We hope that this HANNA INSTRUMENTS HI 96804 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 96804.


Mode d'emploi HANNA INSTRUMENTS HI 96804
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 96804

Detailed instructions for use are in the User's Guide.

[. . . ] The measurement technique and temperature compensation employ methodology recommended in the ICUMSA Methods Book (Internationally recognized body for Sugar Analysis). Temperature (in °C or °F) is displayed simultaneously with the measurement on the large dual level display along with icons for Low Power and other helpful message codes. Key features include: · Dual-level LCD · Automatic Temperature Compensation (ATC) · Easy setup and storage · Battery operation with Low Power indicator (BEPS) · Automatically turns off after 3 minutes of non-use. TABLE OF CONTENTS PRELIMINARY EXAMINATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 GENERAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Sa mp le exceed s ma ximum mea surement ra ng e. Wrong ca lib ra tion used to zero instrument. Wrong ca lib ra tion used to zero instrument. Temp era ture exceed s ATC low limit (10 °C) d uring ca lib ra tion. Temp era ture exceed s ATC hig h limit (40 °C) d uring ca lib ra tion. LO Top d isp la y HI Top d isp la y LO Top d isp la y Cal seg ment ON 1. 8. SETUP: Factory Calibration Tag Measurement in Progress Tag Battery (blinks when low battery condition detected) Calibration Tag Automatic Temperature Compensation (blinks when temperature exceeds 10-40°C / 50-104°F range) Primary Display (displays measurement and error messages) Temperature Units Secondary Display (displays temperature measurements; when blinking, temperature has exceeded operation range: 0-80°C / 32-176°F) HI Top d isp la y Cal seg ment ON t LO Top d isp la y Cal seg ment ON t HI Top d isp la y Cal seg ment ON Air Prism surfa ce insufficiently covered . Too much externa l lig ht for mea surement. Conta ct Ha nna . MEASUREMENT GUIDELINES · · · · Handle instrument carefully. Do not spray water to any part of instrument except the "sample well" located over the prism. The instrument is intended to measure Invert Sugar solutions. Do not expose instrument or prism to solvents that will damage it. This includes most organic solvents and extremely hot or cold solutions. Particulate matter in a sample may scratch the prism. Absorb sample on soft tissue and rinse sample well with deionized or distilled water between samples. Use plastic pipettes to transfer all solutions. Do not use metallic tools such as needles, spoons or tweezers as these will scratch the prism. Elt nLt Ba ttery seg ment b linking <5% of b a ttery life is rema ining . · · Temp era ture va lues a re b linking 0. 0° or 80. 0°C Temp era ture mea surement out of sa mp ling ra ng e (0. 0 to 80. 0°C). Outsid e temp era ture comp ensa tion ra ng e (10 to 40°C). Conta ct Ha nna . ATC seg ment b linking SETUP seg ment b linking 6 7 CALIBRATION Calibration should be performed daily, before measurements are made, when the battery has been replaced, or between a long series of measurements. Two instrument test screens will be displayed briefly; a LCD segment followed by the percentage of remaining battery life. When LCD displays dashes, the instrument is ready. MEASUREMENT Verify the instrument has been calibrated before taking measurements. Wipe off prism surface located at the bottom of the sample well. 2. Using plastic pipettes, fill the sample well with distilled or deionized water. [. . . ] This warranty is limited to repair or replacement free of charge. Damage due to accident, misuse, tampering or lack of prescribed maintenance is not covered. If service is required, contact your dealer. If under warranty, report the model number, date of purchase, serial number and the nature of the failure. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 96804

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 96804 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag