User manual HANNA INSTRUMENTS HI 96831 BROCHURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 96831. We hope that this HANNA INSTRUMENTS HI 96831 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 96831.


Mode d'emploi HANNA INSTRUMENTS HI 96831
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 96831BROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] 5 DISPLAY ELEMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 MEASUREMENT GUIDELINES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 CALIBRATION PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 MEASUREMENT PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] When the display shows "LO", the freezing point is at a minimum (below -50 °C). FUNCTIONAL DESCRIPTION TOP VIEW 1. 8. Liquid Crystal Display (LCD) READ Key (User Measurement) ZERO Key (User Calibration) RANGE Key (User Measurement Unit) ON/OFF Stainless Steel Sample Well and Prism Secondary Display Primary Display 5 BOTTOM 9. Battery Cover 10. Battery Compartment DISPLAY ELEMENTS 1. 9. Battery (blinks when low battery condition detected) Measurement in Progress Tag SETUP: Factory Calibration Tag CAL: Calibration Tag Automatic Temperature Compensation (blinks when temperature exceeds 0-40°C / 32-104°F range) Primary Display (displays measurement and error messages) Temperature Units Secondary Display (displays temperature measurements; when blinking, temperature has exceeded operation range: 0-80°C / 32-176°F) Range indicator 6 MEASUREMENT GUIDELINES · · · · · · · Handle instrument carefully. Do not spray water to any part of instrument except the "sample well" located over the prism. The instrument is intended to measure ethylene glycol solutions. Do not expose instrument or prism to solvents that will damage it. This includes most organic solvents and extremely hot or cold solutions. Particulate matter in a sample may scratch the prism. Absorb sample with a soft tissue and rinse sample well with deionized or distilled water between samples. Use plastic pipettes to transfer all solutions. Do not use metallic tools such as needles, spoons or tweezers as these will scratch the prism. Cover sample well with hand if measuring in direct sun. CALIBRATION PROCEDURE Calibration should be performed daily, before measurements are made, when the battery has been replaced, between a long series of measurements, or if environmental changes have occurred since the last calibration. Two instrument test screens will be displayed briefly; all LCD segments followed by the percentage of remaining battery life. The meter will then briefly display an indication of the measurement unit set. When the LCD displays dashes, the instrument is ready. 2. Using a plastic pipette, fill the sample well with distilled or deionized water. Make sure the prism is completely covered. Note: If the ZERO sample is subject to intense light such as sunlight or another strong source, cover the sample well with your hand or other shade during the calibration. If no error messages appear, your unit is calibrated. (For a description of ERROR MESSAGES see page 11). Note: The 0. 0 screen will remain until a sample is measured or the instrument is turned off. Gently absorb the ZERO water standard with a soft tissue. Use care not to scratch the prism surface. [. . . ] · Once the solution has returned to room temperature use distilled or deionized water to bring the total volume to 100 mL. Mix solution well before use. Et hylene Glycol Tot al Volume 10 % V 40 % V 10. 00 mL 40. 00 mL 100. 00 mL 100. 00 mL Expect ed Freezing Point Value -3. 8 °C (25. 2 °F) -26. 3 °C (-15. 4 °F) BATTERY REPLACEMENT To replace the instrument's battery, follow these steps: · Make sure the instrument is off. · Turn instrument upside down and remove the battery cover by turning it counterclockwise. · Extract the battery from its location. · Replace with a new 9V battery making sure to observe polarity. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 96831

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 96831 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag