User manual HANNA INSTRUMENTS HI 98171

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 98171. We hope that this HANNA INSTRUMENTS HI 98171 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 98171.


Mode d'emploi HANNA INSTRUMENTS HI 98171
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 98171

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual HI 98170 HI 98171 HI 98172 Calibration Check Waterproof pH/mV/ISE/Temperature Meters w w w. c o m 1 Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction manual carefully before using the instruments. This manual will provide you with the necessary information for correct use of the instruments, as well as a precise idea of their versatility. [. . . ] · When an abnormal condition in the RTC is detected, the instrument forces the "expired calibration" status. LAST pH CALIBRATION DATA The last pH calibration data is stored automatically after a successful calibration. To view the pH calibration data, press 2nd then GLP when the instrument is in pH measurement mode. The instrument will display the time (hh:mm) of the last calibration. Press the ARROW keys to view the next calibration parameter (pressing the key): · The date (mm. dd. yyyy) of the last calibration. · The pH calibration offset. 22 · The pH calibration slope (the GLP slope is the average of the calibration slopes; the percentage is referred to the ideal value of 59. 16 mV/pH). · The calibration buffers in calibrating order, for the last calibration. The first pH calibration buffer: The second pH calibration buffer: The third pH calibration buffer: The fourth pH calibration buffer: The fifth pH calibration buffer: Notes: · The "OLd" message displayed beside the pH value means that this buffer was not used during last calibration. Press 2nd then SETUP if you want to see calibration date (or time, if old calibration was performed in the same day with current calibration). In this case, the calibration buffer number is not displayed on the LCD. · If "no bUF" message appears on the LCD, the instrument informs you that calibration was performed in less than five points. · The Calibration Alarm Time Out status. If disabled, or the number of days until the calibration alarm will be displayed (e. g. 5 days), or from the time calibration expired (e. g. · The instrument ID. 23 LAST RELATIVE mV CALIBRATION DATA Last Relative mV calibration data is stored automatically after a successful calibration. To view the Relative mV calibration data, press 2nd then GLP while in Relative mV measurement mode. The instrument will display the Relative mV GLP information. · The time (hh:mm:ss) of the last Rel mV calibration as in pH GLP mode. Press the ARROW keys to view the next calibration parameter (pressing the key): · The Relative mV calibration date as in pH GLP mode. · The Relative mV calibration offset as in pH GLP mode. · The instrument ID as in pH GLP mode. Notes: · Press 2nd then GLP at any moment and the instrument will return to measurement mode. · If calibration has not been performed, the instrument displays "no CAL" message blinking. [. . . ] Use: general purpose. 12 mm 0. 5" HI 4430 120 mm 4. 7" "S" VERSION Consult the Hanna General Catalog for a complete and wide selection of electrodes. PEI® is registered Trademark of "General Electric Co. " PVDF® is registered Trademark of "Pennwalt Corp. " 49 EXTENSION CABLE FOR SCREW-TYPE ELECTRODES (SCREW TO BNC ADAPTER) HI 7855/1 Extension cable 1 m (3. 3') long HI 7855/3 Extension cable 3 m (9. 9') long HI 7855 SERIES CABLE CONNECTORS CONNECTOR AND 3. 0 mm (0. 12") CABLE WITH BNC CONNECT TO SCREW TYPE ELECTRODES CONNECT TO THE BNC SOCKET OF THE METER OTHER ACCESSORIES HI 710041 HI 721317 HI 740157 HI 76405 HI 7662 HI 8427 Inductive Recharger Rugged carrying case Plastic electrode refilling pipet (20 pcs) Electrode holder Stainless steel Temperature probe with 1 m (3. 3') screened cable pH and ORP electrode simulator with 1 m (3. 3') coaxial cable ending in female BNC connectors HI 931001 pH and ORP electrode simulator with LCD and 1 m (3. 3') coaxial cable ending in female BNC connectors 50 RECOMMENDATIONS FOR USERS Before using these products, make sure they are entirely suitable for the environment in which they are used. Operation of these instruments in residential areas could cause unacceptable interferences to radio and TV equipment, requiring the operator to follow all necessary steps to correct interferences. The glass bulb at the end of the pH electrode is sensitive to electrostatic discharges. Avoid touching this glass bulb at all times. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 98171

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 98171 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag