User manual HANNA INSTRUMENTS HI 98280

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 98280. We hope that this HANNA INSTRUMENTS HI 98280 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 98280.


Mode d'emploi HANNA INSTRUMENTS HI 98280
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 98280

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual HI 9828 Multiparameter Meter with GPS w w w. h a n n a i n s t . c o m 1 Dear Customer, Thank you for choosing a HANNA instruments® product. Please read this instruction manual carefully before using the instrument. It will provide you with the necessary information for correct use of the instrument, as well as a precise idea of its versatility. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst. com or see the back cover for our worldwide contact list. [. . . ] · Press <OK> to return to the "Calibration" menu. · To return to the main menu, press ESC repeatedly. Salinity · Select the "Salinity" option and press <OK>. · Insert the salinity value of the custom calibration solution. · Immerse the probe in the solution and wait for stable reading. · When the reading is stable, press <Confirm> to store the calibration data. · After confirmation, the following messages are displayed: "Storing data on probe, please wait. . . ", "Updating GLP data, please wait. . . " and "Calibration completed". · Press <OK> to return to the "Calibration" menu. · To return to the main menu, press ESC repeatedly. Notes These procedures calibrate the slope value. To calibrate the offset, set the calibration point at 0 S/cm and repeat the procedure. If the temperature input is not within the acceptable range (0 to 50°C), the message "Invalid temperature" is displayed. If the conductivity input is not within the acceptable range, the message "Invalid input" is displayed. · To change the standard value, press <Cal. point> and the list of available standard values is displayed: 0 S/cm, 84 S/cm, 1413 S/cm, 5. 00 mS/cm, 12. 88 mS/cm, 80. 0 mS/cm and 111. 8 mS/cm. · Press <Custom> to insert a custom value (temperature compensated value). Choose <Resolution> to select the desired resolution. · When the reading is stable, press <Confirm> to store the calibration data. · After confirmation, the following messages are displayed: "Storing data on probe, please wait. . . ", "Updating GLP data, please wait. . . " and "Calibration completed". · Press <OK> to return to the "Calibration" menu. · To return to the main menu, press ESC repeatedly. 36 37 4. 5 ATMOSPHERIC PRESSURE CALIBRATION For this procedure a reference barometer is needed. During calibration the current reading can differ up to 40 mbar from the calibration point. Choose the "Atmospheric pressure" option from the "Calibration" menu, then select the calibration type using the arrow keys and press <OK>. [. . . ] If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to HANNA instruments®, first obtain a Returned Goods Authorization number from the Customer Service department and then send it with shipping costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection. HI 5010 pH 10. 01 buffer solution, 500 mL bottle ORP SOLUTIONS HI HI HI HI 7020L 7021L 7022L 7091L ORP test solution, 200/275 mV @20°C, 500 mL ORP test solution, 240 mV @20°C, 500 mL bottle ORP test solution, 470 mV @20°C, 500 mL bottle Reducing pretreatment solution, 500 mL bottle Oxidizing pretreatment solution, 500 mL bottle HI 7092L ACCESSORIES FOR DO MEASUREMENTS HI 7040L HI 7042S HI 76409A/P Zero oxygen solution, 500 mL bottle Electrolyte solution for DO sensor, 30 mL bottle Spare membrane with O-ring (5 pcs) CONDUCTIVITY STANDARD SOLUTIONS HI HI HI HI HI 7030L 7031L 7033L 7034L 7035L 12880 S/cm standard solution, 500 mL bottle 1413 S/cm standard solution, 500 mL bottle 84 S/cm standard solution, 500 mL bottle 80000 S/cm standard solution, 500 mL bottle 111800 S/cm standard solution, 500 mL bottle 5000 S/cm standard solution, 500 mL bottle HI 7039L PROBE CLEANING & MAINTENANCE SOLUTIONS HI 70670L HI 70671L HI 70300L Cleaning solution for salt deposits, 500 mL bottle Cleaning and disinfection solution for algae, fungi and bacteria, 500 mL bottle Electrode storage solution, 500 mL Recommendations for Users Before using this product, make sure that it is entirely suitable for the environment in which it is used. Operation of this instrument in residential areas could cause unacceptable interferences to radio and TV equipment, requiring the operator to take all necessary steps to correct interferences. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 98280

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 98280 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag