If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 99141. We hope that this HANNA INSTRUMENTS HI 99141 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 99141.


Mode d'emploi HANNA INSTRUMENTS HI 99141
Download

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 99141 (78 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 99141

Detailed instructions for use are in the User's Guide.

[. . . ] The probes are warranted for a period of six months. This warranty is limited to repair or replacement free of charge. Damages due to accident, misuse, tampering or lack of prescribed maintenance are not covered. If service is required, contact the dealer from whom you purchased the instrument. [. . . ] Press any button to return to normal mode. To turn the meter OFF While in normal measurement mode, press the ON/OFF/MODE button. OFF will appear on the secondary display. Note: The meter is provided with an acoustic signal feature which can be disabled using the switch located in the battery compartment. Note: When the meter detects the absence of a temperature probe at its input, the Automatic Temperature Compensation is turned off, and the meter uses a default value of 25°C (77°F) for the temperature measurement and compensation. In this condition, the secondary LCD shows 25. 0°C (77. 0°F) blinking. When a probe is connected, the meter automatically returns to the ATC mode, the ATC tag is turned on, and the temperature is shown on the secondary display. pH MEASUREMENT & CALIBRATION · Make sure the meter has been calibrated before use. · If the probe is dry, soak it in HI 70300 storage solution for one hour to reactivate it. · Place the tip of the probe into the sample to be tested. · Stir briefly and wait until the symbol on the top left of the LCD is turned off. · The LCD shows the pH value (automatically compensated for temperature) on the primary LCD, while the secondary LCD shows the temperature of the solution. · If measurements are taken in different samples successively, rinse the probe tip thoroughly to eliminate cross-contamination. After cleaning, rinse the probe tip with some of the sample to be measured. pH calibration For better accuracy, frequent calibration of the instrument is recommended. In addition, the instrument must be recalibrated whenever: a) The pH electrode is replaced. · From normal mode, press and hold the ON/ OFF/MODE button until OFF on the secondary display is replaced by CAL. · The LCD enters the calibration mode, displaying "pH 7. 01 USE" (or "pH 6. 86 USE" if the NIST buffer set was selected). After 1 second the meter activates the automatic buffer recognition feature. If a valid buffer is detected, then its value is shown on the primary display, and REC appears on the secondary LCD. If no valid buffer is detected, the meter keeps the USE indication active for 12 seconds, and then replaces it with WRNG, indicating that the sample being measured is not a valid buffer. · For a single-point calibration with buffers pH 4. 01, 9. 18 or 10. 01, the meter automatically accepts the calibration when the reading is stable; the meter will show on the primary display the accepted buffer, with the message "OK 1" on the secondary display, and an audible signal is produced. After 1 second the meter automatically returns to the normal measuring mode. [. . . ] To enter the Setup mode, press and hold the ON/ OFF/MODE button until CAL on the secondary display is replaced by TEMP and the current temperature unit (E. g. Then: · for °C/°F selection, use the SET/HOLD button. After the temperature unit has been selected, press ON/OFF/MODE to enter the buffer set selection mode; press ON/OFF/MODE twice to return to the normal measuring mode. · to change the calibration buffer set, after setting the temperature unit, the meter will show the current buffer set: "pH 7. 01 BUFF" (for 4. 01/ 7. 01/10. 01) or "pH 6. 86 BUFF" (for 4. 01/6. 86/ 9. 18). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 99141

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 99141 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag