User manual HANNA INSTRUMENTS PH 500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS PH 500. We hope that this HANNA INSTRUMENTS PH 500 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS PH 500.


Mode d'emploi HANNA INSTRUMENTS PH 500
Download

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS PH 500 (1838 ko)

Manual abstract: user guide HANNA INSTRUMENTS PH 500

Detailed instructions for use are in the User's Guide.

[. . . ] pH 500/mV 600 Series Panel-mounted, Microprocessor-based Process pH/mV Meters Instruction Manual Dear Customer, Thank you for choosing a Hanna Product. This instruction manual has been written for the following products: pH 500111 pH Controller with single setpoint, ON/OFF control, analog output pH 500112 pH Controller with single setpoint, ON/OFF control, RS232 output pH 500121 pH Controller with single setpoint, proportional and ON/OFF control, analog output pH 500122 pH Controller with single setpoint, proportional and ON/OFF control, RS232 output pH 500211 pH Controller with dual setpoint, ON/OFF control, analog output pH 500212 pH Controller with dual setpoint, ON/OFF control, RS232 output pH 500221 pH Controller with dual setpoint, proportional and ON/OFF control, analog output pH 500222 pH Controller with dual setpoint, proportional and ON/OFF control, RS232 output mV 600111 ORP Controller with single setpoint, ON/OFF control, analog output mV 600112 ORP Controller with single setpoint, ON/OFF control, RS232 output mV 600121 ORP Controller with single setpoint, proportional and ON/OFF control, analog output mV 600122 ORP Controller with single setpoint, proportional and ON/OFF control, RS232 output Please read this instruction manual carefully before using the instrument. It will provide you with the necessary information for the correct use of the instrument, as well as a precise idea of its versatility. These instruments are in compliance with directives. All rights are reserved. [. . . ] · After the first calibration point is confirmed, immerse the pH electrode with the Potential Matching Pin into the second buffer (e. g. pH 4. 01) and stir gently Note Note If you are not going to perform a three-point calibration, it is recommendable to use pH 4. 01 buffer if you are going to measure acid samples, or use pH 10. 01 buffer for alkaline samples. The electrode should be submerged approximately 4 cm (1½") in the solution. The temperature probe should be located as close as possible to the pH electrode. · Select the 2nd buffer value on the secondary display by pressing or (e. g. pH 4. 01). · Only when the reading is stable the probe indicator " " will stop flashing (after about 30 seconds) and the "CFM" indicator will blink. · Press CFM to confirm the calibration; if the reading is close to the selected buffer, the meter stores the reading, adjusting the slope point and the secondary LCD will display the expected third buffer value. If the reading is not close to the selected buffer, "WRONG " will blink. BUF · Press CAL and the calibration process is ended with the offset and the 1st slope of the meter calibrated. 30 Three-point Calibration · Proceed as described above but do not quit calibration by pressing CAL. Note The meter will automatically skip the two buffers that were used to prevent errors. · After the second calibration point is confirmed, immerse the pH electrode and the Potential Matching Pin into the third buffer solution (e. g. pH 10. 01) and stir gently. Note The electrode should be submerged approximately 4 cm (1½") in the solution. The temperature probe should be located as close as possible to the pH electrode. · Only when the reading is stable the probe indicator " " will stop flashing (after about 30 seconds) and the "CFM" indicator will start blinking. · Press CFM to confirm the calibration; if the reading is close to the selected buffer, the meter stores the reading, adjusting the 2nd slope point and the calibration process is ended with the offset and the 1st and 2nd slope of the meter calibrated. If the reading is not close to the selected buffer, "WRONG " will blink. BUF Note During calibration, the secondary LCD displays the selected buffer value. By pressing LCD the temperature can be displayed. This will allow you to check the buffer temperature during calibration. 31 CALIBRATION WITH MANUAL TEMPERATURE COMPENSATION · Enter the calibration procedure and press LCD to display the temperature on the secondary LCD. · Unplug any temperature probe that may be attached to the meter. The "°C" symbol will flash. · Note the temperature of the buffer solutions with a ChecktempC or an accurate thermometer with a resolution of 0. 1°C. · Use or to manually adjust the display reading to the value of the reference thermometer (e. g. 20°C). · Follow the calibration procedure above (see page 27). Note To toggle between the pH buffer and the temperature press LCD. When a one-point calibration is carried out only the pH offset is computed and stored, while the pH slope is fixed according to the theoretical values. With a two-point calibration, offset and slope are computed to fit the two calibration points. With a three-point calibration the offset and first slope values refers to pH 4. 01 and 7. 01 buffers, while the second slope refers to pH 7. 01 and 10. 01 buffers. Note If the process meter has never been calibrated or an EEPROM reset has occurred, the meter continues to perform measurement. However, user is informed of a pH calibration requirement by a blinking "CAL" (see "Startup" section). [. . . ] The protective cap can also be filled with HI 70300 Storage Solution if the electrode is not being used at all. With industrial applications, it is always recommended to keep at least one spare electrode handy. When anomalies are not resolved with a simple maintenance, change the electrode to see if the problem is alleviated. 53 ACCESSORIES pH CALIBRATION SOLUTIONS HI 7004M pH 4. 01 Buffer Solution, 230 mL HI 7004L pH 4. 01 Buffer Solution, 460 mL HI 7004/L pH 4. 01 Buffer Solution, 1 L HI 7007M pH 7. 01 Buffer Solution, 230 mL HI 7007L pH 7. 01 Buffer Solution, 460 mL HI 7007/L pH 7. 01 Buffer Solution, 1 L HI 7010M pH 10. 01 Buffer Solution, 230 mL HI 7010L pH 10. 01 Buffer Solution, 460 mL HI 7010/L pH 10. 01 Buffer Solution, 1 L ORP SOLUTIONS HI 7020M HI 7020L HI 7091M HI 7091L HI 7092M HI 7092L 200-275mV Buffer Solution, 230 mL 200-275mV Buffer Solution, 460 mL Pretreatment Reducing Solution, 230 mL Pretreatment Reducing Solution, 460 mL Pretreatment Oxidizing Solution, 230 mL Pretreatment Oxidizing Solution, 460 mL ELECTRODE STORAGE SOLUTIONS HI 70300M Storage Solution, 230 mL HI 70300L Storage Solution, 460 mL ELECTRODE CLEANING SOLUTIONS HI 7061M General Cleaning Sol. , 230 mL HI 7061L General Cleaning Sol. , 460 mL HI 7073M Protein Cleaning Sol. , 230 mL HI 7073L Protein Cleaning Sol. , 460 mL HI 7074M Inorganic Cleaning Sol. , 230 mL HI 7074L Inorganic Cleaning Sol. , 460 mL HI 7077M Oil & Fat Cleaning Sol. , 230 mL HI 7077L Oil & Fat Cleaning Sol. , 460 mL REFILL ELECTROLYTE SOLUTIONS HI 7071 3. 5M KCl+AgCl Electrolyte, 4x50 mL, for single junction electrodes HI 7072 1M KNO3 Electrolyte, 4x50 mL HI 7082 3. 5M KCl Electrolyte, 4x50 mL, for double junction electrodes 54 RECOMMENDED pH ELECTRODES (All electrodes gel-filled and with ceramic junction unless otherwise indicated). HI 1090T Screw connector, external PG13. 5 thread, double junction, glass-body, polymer filled HI 1210T HI 1211T Screw connector, external PG13. 5 thread, double junction, Ultem®-body; cloth junction (HI 1210T); Teflon® junction, polymer-filled (HI 1211T) HI 2910B/5 HI 2911B/5 BNC connector, 5 m (16. 5') cable, double junction, Ultem®body with built-in amplifier and external thread; cloth junction (HI 2910B/5); Teflon® junction, polymer-filled (HI 2911B/ 5) HI 1090B/5 BNC connector, 5 m (16. 5') cable, double junction, glassbody, polymer-filled HI 1210B/5 BNC connector, 5 m (16. 5') cable, double junction, Ultem®body, Teflon® junction, polymer-filled 55 PLATINUM ORP ELECTRODES HI 3090T Screw connector, external PG13. 5 thread, double junction, Pt, glass-body, polymer filled HI 3210T Screw connector, external PG13. 5 thread, double junction, Pt, Ultem®-body, cloth junction HI 3211T Screw connector, external PG13. 5 thread, double junction, Pt, Ultem®-body, Teflon® junction, polymer-filled HI 2930B/5 BNC connector, 5 m (16. 5') cable, double junction, Pt, Ultem®-body with built-in amplifier and external thread, cloth junction HI 2931B/5 BNC connector, 5 m (16. 5') cable, double junction, Pt, Ultem®-body with built-in amplifier and external thread, Teflon® junction, polymer-filled HI 3090B/5 BNC connector, 5 m (16. 5') cable, double junction, Pt, glassbody, polymer-filled 56 HI 3210B/5 BNC connector, 5 m (16. 5') cable, double junction, Pt, Ultem®-body, Teflon® junction, polymer-filled GOLD ORP ELECTRODES HI 4932B/5 BNC connector, 5 m (16. 5') cable, double junction, Au, Ultem®-body with built-in amplifier and external thread ELECTRODES FOR HIGH PRESSURE APPLICATIONS pH ELECTRODES ½`' thread, double Teflon® junction, polymer filled, max operating pressure of 6 bar (87 psi) Part Code HI 1002/3 HI 1002/5 HI 1003/3 HI 1003/5 HI 1004/5 Matching Pin Amplifier NO NO YES YES YES NO NO NO NO YES Connector BNC BNC BNC* BNC* Cable 3 m (10') 5 m (16. 5') 3 m (10') 5 m (16. 5') spade lugs* 5 m (16. 5') * In addition to the electrode connector, there is also a spade lug connection for the matching pin 57 ORP ELECTRODES ½`' thread, double Teflon® junction, polymer filled, max operating pressure of 6 bar (87 psi) PLATINUM ELECTRODES Part Code HI 2002/3 HI 2002/5 HI 2003/3 HI 2003/5 HI 2004/5 GOLD ELECTRODES Part Code HI 2012/3 HI 2012/5 HI 2013/3 HI 2013/5 HI 2005/5 Matching Pin Amplifier NO NO YES YES YES NO NO NO NO YES Connector BNC BNC BNC* BNC* Cable 3 m (10') 5 m (16. 5') 3 m (10') 5 m (16. 5') Matching Pin Amplifier NO NO YES YES YES NO NO NO NO YES Connector BNC BNC BNC* BNC* Cable 3 m (10') 5 m (16. 5') 3 m (10') 5 m (16. 5') spade lugs* 5 m (16. 5') spade lugs* 5 m (16. 5') * In addition to the electrode connector, there is also a spade lug connection for the matching pin Ultem® is a registered Trademark of "General Electrics Company" 58 OTHER ACCESSORIES BL PUMPS ChecktempC ChecktempF HI 6050 & HI 6051 HI 6054 & HI 6057 HI 778P HI 7871 & HI 7873 HI 8427 HI 8614 HI 8614L HI 8615 HI 8615L HI 920010 HI 920010-9 HI 92500 HI 931001 HI 931002 Dosing Pumps with Flow Rate from 1. 5 to 20 LPH Stick Thermometer (range -50. 0 to 150. 0°C) Stick Thermometer (range -58. 0 to 302°F) Submersible Electrode Holders Electrode Holders for In-Line Applications Screened Coaxial Cable and Screw Connectors Level Controllers pH / ORP Electrode Simulator pH Transmitter pH Transmitter with LCD ORP Transmitter ORP Transmitter with LCD 9 to 25-pin Connection RS 232 Cable 9 to 9-pin Connection RS 232 Cable Windows® Compatible Application Software pH / ORP Electrode Simulator with LCD Display 4-20 mA Simulator 59 WARRANTY All Hanna Instruments meters are guaranteed for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS PH 500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS PH 500 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag