If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS PH211 R. We hope that this HANNA INSTRUMENTS PH211 R user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS PH211 R.


Mode d'emploi HANNA INSTRUMENTS PH211 R
Download
Manual abstract: user guide HANNA INSTRUMENTS PH211 R

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual pH211R Microprocessor-based Bench pH/mV/°C Meter with Analog Output www. hannainst. com Dear Customer, Thank you for choosing a Hanna Instruments Product. Please read this instruction manual carefully before using the instrument. This manual will provide you with all the necessary information for correct use of the instrument, as well as a precise idea of its versatility in a wide range of applications. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst. com. [. . . ] It also skips pH 6. 86 if 7. 01 was used, and viceversa, and pH 9. 18 if 10. 01 was used, and viceversa. · The "NOT READY" indication will blink on LCD until the reading has stabilized. · When the reading is stable, "READY" and "CFM" will blink. Press CFM to confirm the calibration. · If the reading is close to the selected buffer value, the meter stores the calibration point. The "Stor" message appears on the LCD for 1 second, then the buffer value is displayed on the primary LCD and the secondary LCD displays the second expected buffer value. · If the measured value is not close to the selected buffer, the "WRONG " and "WRONG " symbols will blink alternately. In this case check if the correct buffer has been used or refresh the electrode by following the maintenance procedure (see "Electrode Maintenance" section). If necessary change the buffer or the electrode. 10 · If the reading is close to the selected buffer, the meter stores the calibration point, displays the "Stor" message for 1 second and returns to normal operational mode. · If the measured value is not close to the selected buffer, "WRONG " and "WRONG " will blink alternately. In this case check if the correct buffer has been used, or refresh the electrode by following the maintenance procedure (see "Electrode Maintenance" section). If necessary change buffer or electrode. Note: Press RANGE to display the temperature reading on the LCD during calibration. 11 ELECTRODE CONDITIONING & MAINTENANCE Note: To prevent damage to the pH electrode, remove it from the solution before turning the meter off. With the meter OFF, detach the electrode from the instrument and immerse it in the storage solution. For refillable electrodes If the filling solution (electrolyte) is more than 2. 5 cm (1") below the fill hole, add HI 7082 3. 5M KCl electrolyte solution for double junction or HI 7071 3. 5M KCl+AgCl electrolyte solution for single junction electrodes. For a faster response, unscrew the fill hole screw during measurements. Removal of films, dirt or deposits on the membrane/junction: - Protein Soak in Hanna HI 7073 protein cleaning solution for 15 minutes. - Inorganic Soak in Hanna HI 7074 inorganic cleaning solution for 15 minutes. - Oil/grease Rinse with HI 7077 Oil & Fat cleaning solution. IMPORTANT: After performing any of the cleaning procedures rinse the electrode thoroughly with distilled water, refill the reference chamber with fresh electrolyte (not necessary for gel-filled electrodes) and soak the electrode in HI 70300 storage solution for at least 1 hour before taking measurements. TROUBLESHOOTING Evaluate the performance of your electrode based on the following. · Noise (readings fluctuate up and down) could be due to: ­ Clogged/Dirty Junction: refer to the Cleaning Procedure. ­ Loss of shielding due to low electrolyte level (in refillable electrodes only): refill with fresh HI 7071 for single junction or HI 7082 for double junction electrodes. · Dry Membrane/Junction: soak in HI 70300 storage solution for at least 1 hour. · Drifting: soak the electrode tip in warm (approx. [. . . ] When shipping any instrument, make sure it is properly packaged for complete protection. CONNECT TO SCREW TYPE ELECTRODES CONNECT TO THE BNC SOCKET OF THE METER OTHER ACCESSORIES HI 710005 HI 710006 HI 710012 HI 710013 HI 710014 HI 76404 Voltage adapter, 115 Vac / 12 Vdc, US plug Voltage adapter, 230 Vac / 12 Vdc, European plug Voltage adapter, 230 Vac / 12 Vdc, UK plug Voltage adapter, 230 Vac / 12 Vdc, S. Africa plug Voltage adapter, 230 Vac / 12 Vdc, Australian plug Electrode holder All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner. HI 7669/2W HI 8427 HI 931001 HI 98501 Temperature probe with 1 m (3. 3') cable pH/ORP electrode simulator pH/ORP electrode simulator with LCD ChecktempC pocket-size thermometer (range: -50. 0 to 150. 0°C) Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. Recommendations for Users Before using this product, make sure that it is entirely suitable for the environment in which it is used. Operation of this instrument in residential areas could cause unacceptable interferences to radio and TV equipment, requiring the operator to take all necessary steps to correct interferences. The glass bulb at the end of the pH electrode is sensitive to electrostatic discharges. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS PH211 R

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS PH211 R will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag