User manual HAWKE 710 32R4 ASSEMBLY

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAWKE 710 32R4. We hope that this HAWKE 710 32R4 user guide will be useful to you.

Lastmanuals help download the user guide HAWKE 710 32R4.


Mode d'emploi HAWKE 710 32R4
Download
Manual abstract: user guide HAWKE 710 32R4ASSEMBLY

Detailed instructions for use are in the User's Guide.

[. . . ] Pass the brass pot over pot cap and remove any surplus compound from the top of brass pot and joint faces as indicated. E Replace the entry over the brass pot ensuring that compound does not cover end of brass pot Note: If the equipment has a threaded entry it may be advisable to screw the entry component into the equipment to prevent twisting of the cable after step F F Locate and hand tighten the sub-assembly and to the entry . While holding the entry with a spanner / wrench add half a turn to the middle nut . Unscrew the sub-assembly and from the entry then remove any surplus compund from the gland components. [. . . ] Check that compound has cured. IMPORTANT: The conductors must not be moved for a minimum of four hours. AI 316 - Issue M / Page 2 of 4 I Hand tighten the sub-assembly and to the entry and add half a turn to with a spanner / wrench. Tighten the backnut to form a seal around the cable, then tighten a further half to full turn using a spanner / wrench. Ensure that the middle nut does not rotate when tightening the backnut . Ensure that the deluge seal is pulled into position if fitted. Locate the shroud over the cable gland if applicable. The following instructions are the approved methods of passing drain wires etc. through the compound barrier and should be followed if permitted by cable installation specifications. UNINSULATED EARTH OR DRAIN WIRE PREPARATION 1. 0 INSULATING EARTH OR DRAIN WIRES WITH HEAT SHRINK OR COLD SHRINK TUBING 1. 1 Remove foils and tape level with the inner sheath, exposing the uninsulated earth or drain wires and insulated conductors. Cut back a further 10mm of inner sheath. 1. 2 Pass 100mm length of heat shrink or cold shrink tubing over the uninsulated earth or drain wire until it comes into contact with the foils, then shrink the tubing evenly down onto the uninsulated earth or drain wire so that no air pockets occur. 1. 3 To insulate the joint between the foils and the tubing a suitable piece of 10mm long shrink tubing or neoprene stretch tubing or a 10mm wide lap of PVC tape may be used. 1. 4 After completing 1. 1 to 1. 4 on each earth or drain wire, lay the armour parallel to the cable, if applicable, then carry out instruction B. INDIVIDUAL SHIELDING OR SCREEN PREPARATION 2. 0 INSULATING SCREENS WITH HEAT SHRINK OR COLD SHRINK TUBING 2. 1 Unravel one or two groups of wires from the individual shielding or screen wires, then remove the remainder of the individual shielding or screen wires (See Fig. 2) and twist the wires along their full length. 2. 2 Pass 100mm length of heat shrink or cold shrink tubing over the individual shielding or screen until it comes into contact with the foils, then shrink the tubing evenly down onto the individual shielding or screen so that no air pockets occur. 2. 3 To insulate the joint between the individual shielding or screen wires and the tubing, place one lap of PVC insulating tape over the exposed metallic joint. 2. 4 After completing 2. 1 to 2. 5 on each individual shielding or screen, lay the armour parallel to the cable. Then carry out instruction B. Inner Sheath Shielding Screen Wires One or two groups of shielding screen wires Fig. 2 Inner Sheath Foils Outer Sheath Fig. 3 10mm Earth or Drain Wire or Twisted Screen Fig. 4 Insulated Earth Drain Wire or Twisted Screen Fig. [. . . ] A grounding / earth tag has been provided for use as a grounding point when the cable gland is used with plastic enclosures. This must be fitted to the wall of the enclosure using the threads of the gland and the locknut supplied. Note: Grounding must be carried out in accordance with National Electrical Code Article 250 and 505. 25. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAWKE 710 32R4

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAWKE 710 32R4 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag