User manual HAWKE PSG 553-RAC EXD IIC-EXE II EXTD ASSEMBLY AI312 ISSUE M 11-08

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAWKE PSG 553-RAC EXD IIC-EXE II EXTD. We hope that this HAWKE PSG 553-RAC EXD IIC-EXE II EXTD user guide will be useful to you.

Lastmanuals help download the user guide HAWKE PSG 553-RAC EXD IIC-EXE II EXTD.


Mode d'emploi HAWKE PSG 553-RAC EXD IIC-EXE II EXTD
Download
Manual abstract: user guide HAWKE PSG 553-RAC EXD IIC-EXE II EXTDASSEMBLY AI312 ISSUE M 11-08

Detailed instructions for use are in the User's Guide.

[. . . ] Assembly Instructions for cable gland: PSG 553/RAC Exd IIC/Exe II ExtD Operating temperature range -60°C +80°C 1 2 International Assembly Instructions AI 312 / Issue M - 11/08 Certification Details Gland Type: PSG 553/RAC Exd IIC/Exe II/ExtD Baseefa06ATEX0056X II 2 GD A21 IP66 IECEx BAS06. 0013X CNEx07. 0897X 3 4 5 Reversible Armour Clamping Ring (RAC) 6 General identification ring orientation for: SWA Position Braid 'X', Flat Steel Wire 'Y', Steel Tape 'Z' Ring Position 1. 6. Backnut Middle Nut Reversible Armour Clamping Ring (RAC) Armour Spigot Seal Entry (with captive deluge seal), if required IMPORTANT: The arrowhead indicating the correct armour thickness or type should point towards the equipment Note: Cable acceptance sizes are marked on the diaphragm seal, clamping ring and backnut. Cable Preparation Gland Preparation Armour/braid 6 II 4 5 3 I I 4 3 3 2 1 Note: Tape armour must be re-trimmed at 90° to the vertical axis of the cable after it has been spread, to ensure that the full face is correctly presented. 2 2 1 1 Shroud Option A Strip Cable to suit equipment as shown above and expose the armour/braid 'I' removing all cable fillers. [. . . ] UK www. ehawke. com AI 312 - Issue M / Page 1 of 2 Sales (UK): 0870 606 0105 Sales: +44 (0) 161 830 6698 Technical (UK): 0870 458 9358 Technical: +44 (0) 161 830 6697 Fax: +44 (0) 161 830 6648 E-mail: sales@ehawke. com 6 6 6 4 2 3 5 2 1 1 2 1 D Hold the entry in position with a spanner/wrench to prevent rotation. Hand tighten the middle nut to the entry and turn a further ½ to ¾ of a turn with a spanner/wrench. IMPORTANT: Support the cable to prevent it from twisting. E Unscrew the middle nut and visually inspect that the armour/braid has been successfully clamped between the armour spigot and the armour clamping ring . If armour/braid not clamped, repeat assembly. Note : If the equipment has a threaded entry, it may be advisable to screw the cable gland into the equipment to prevent twisting of the cable after Step E F Select the correct punch tool to suit the conductors sizes (see table) and cut out the required number of holes in the seal using the indented positions as a guide. Remove the entry and pass the individual conductors through the appropriately sized punched holes in the seal ensuring they are not twisted or kinked, and slide the seal down to the spigot . Replace entry and re-assemble middle nut onto the entry component . Tighten up the middle nut until hand tight, then using a wrench/spanner turn the nut through a minimum of one full turn. Tighten the backnut to form a seal around the cable, then tighten a further full turn using a wrench/spanner. Ensure that the middle nut does not rotate when tightening the backnut . Ensure that the deluge seal is pulled down into position, if fitted. Locate the shroud over the cable gland, if applicable. CABLE GLAND SELECTION TABLE Size Ref. A B C Male Entry Thread Size Metric M20 M25 M32 NPT ½" - ¾" ¾" - 1" 1" - 1¼" Outer Sheath Min. 20. 5 26. 0 33. 0 Steel Wire Armour/ Tape/Braid Orientation 1 0. 8/1. 25 1. 25/1. 6 1. 6/2. 0 Orientation 2 0/0. 8 0/0. 7 0/0. 7 Max Length 80 88 95 Hexagon Dimensions Across Flats 30. 0 36. 0 46. 0 Across Corners 34. 6 41. 6 53. 1 CABLE GLAND SIZE FOR CONDUCTOR Maximum No. [. . . ] Earthtag, to provide an external armour/braid bonding point. Serrated washer, to dampen any vibrations that may loosen the locknut or cable gland assembly. AI 312 - Issue M / Page 2 of 2 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAWKE PSG 553-RAC EXD IIC-EXE II EXTD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAWKE PSG 553-RAC EXD IIC-EXE II EXTD will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag