User manual HEAT AND GLO SOHO24B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HEAT AND GLO SOHO24B. We hope that this HEAT AND GLO SOHO24B user guide will be useful to you.

Lastmanuals help download the user guide HEAT AND GLO SOHO24B.


Mode d'emploi HEAT AND GLO SOHO24B
Download
Manual abstract: user guide HEAT AND GLO SOHO24B

Detailed instructions for use are in the User's Guide.

[. . . ] Owner's Manual Installation and Operation Model: Soho24B NOTICE DO NOT DISCARD THIS MANUAL · Important operating and maintenance instructions included. · Read, understand and follow these instructions for safe installation and operation. · Leave this manual with party responsible for use and operation. D DI O N SC OT AR D WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death. · DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. [. . . ] (111 mm), the heat shields on the cap and wall shield firestop must to be trimmed. · Use an extended heat shield if the finished wall thickness is greater than 7-1/4 in. · The extended heat shield may need to be cut to length maintaining sufficient length for a 1-1/2 in. · Attach the extended heat shield to either of the existing heat shields using the screws supplied with the extended heat shield. Refer to vent components diagrams in the back of this manual. (1 of 3) STORM COLLAR SCREWS CAULK Figure 8. 20 J. Install Decorative Wall Components A decorative wall thimble can be installed on wall through which the vent passes. The decorative wall thimble is used to cover the firestop. · Slide the decorative wall thimble over the last section of horizontal pipe before connecting the termination cap to the pipe. · Once the pipe section and the termination cap have been connected, slide the wall thimble up to the interior wall surface and attach with screws provided. See Figure 8. 21. · Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section. Important Notice: Heat shields may not be field constructed. Figure 8. 21 Wall Thimble 26 Heat & Glo · Soho24B · 2137-900 Rev. Install Horizontal Termination Cap WARNING!The telescoping flue section of the termination cap MUST be used when connecting vent. · 1-1/2 (38 mm) minimum overlap of flue telescoping section is required. Failure to maintain overlap may cause overheating and fire. · Vent termination must not be recessed in the wall. Siding may be brought to the edge of the cap base. · Flash and seal as appropriate for siding material at outside edges of cap. · When installing a horizontal termination cap, follow the cap location guidelines as prescribed by current ANSI Z223. 1 and CAN/CGA-B149 installation codes and refer to Section 6 of this manual. Local codes may require installation of a cap shield to prevent anything or anyone from touching the hot cap. NOTICE: For certain exposures which require superior resistance to wind-driven rain penetration, a flashing kit and HRC caps are available. When penetrating a brick wall, a brick extension kit is available for framing the brick. Note: When using termination caps with factory-supplied heat shield attached, no additional wall shield firestop is required on the exterior side of a combustible wall. HEAT SHIELD OR EXTENDED HEAT SHIELD WALL SHIELD FIRESTOP HEAT SHIELD 1-1/2 IN. [. . . ] H · 10/08 4021-645A 09-01-08 51 D. Limited Lifetime Warranty (continued) · This limited warranty does not extend to or include surface finish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, firebrick, pellet logs, kaowool or other ceramic insulating materials. Rust and/or corrosion on any of the metal surfaces, cast iron components, baffles, firepots, doors, or firebox area are not covered by this warranty. · Noise resulting from minor expansion, contraction, or movement of certain parts is normal and complaints related to this noise are not covered by this warranty. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HEAT AND GLO SOHO24B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HEAT AND GLO SOHO24B will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag