User manual HITACHI L200-2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HITACHI L200-2. We hope that this HITACHI L200-2 user guide will be useful to you.

Lastmanuals help download the user guide HITACHI L200-2.


Mode d'emploi HITACHI L200-2
Download

You may also download the following manuals related to this product:

   HITACHI L200-2 QUICK REFERENCE GUIDE (353 ko)

Manual abstract: user guide HITACHI L200-2

Detailed instructions for use are in the User's Guide.

[. . . ] Cover L2002 Series Inverter Instruction Manual · Single-phase Input 200V Class · Three-phase Input 200V Class · Three-phase Input 400V Class Manual Number: NB675X Sept. 2006 After reading this manual, keep it handy for future reference. Hitachi Industrial Equipment Systems Co. , Ltd. L2002 Inverter i Safety Messages For the best results with the L2002 Series inverter, carefully read this manual and all of the warning labels attached to the inverter before installing and operating it, and follow the instructions exactly. Keep this manual handy for quick reference. Definitions and Symbols A safety instruction (message) includes a "Safety Alert Symbol" and a signal word or phrase such as WARNING or CAUTION. Each signal word has the following meaning: HIGH VOLTAGE: This symbol indicates high voltage. [. . . ] The settings cannot be edited via the network, in order to ensure network reliability. Refer to "ModBus Network Communications" on page B­1 for more information on controlling and monitoring your inverter from a network. "C" Function Func. Code Name / SRW Display Description Three option codes: 04. . . 19200 bps Set the address of the inverter on the network. Run Defaults Mode Edit ­FE(F) ­FU Units Lo Hi (EU) (USA) 06 04 baud C071 Communication speed selection COM BAU C072 Node allocation COM ADR 00001 4800 1. . 1 -- Configuring Drive Parameters C074 Communication parity selection COM PRTY Three option codes: 00. . . Odd parity 00 00 -- C075 Communication stop bit Range is 1 to 2 selection COM STP 1BIT Selects inverter response to communications error. Decelerate to a stop and trip (error code E60) 02. . . Decelerate to a stop Sets the communications watchdog timer period. Time the inverter waits after receiving a message before it transmits. ms 1 1 -- C076 Communication error select COM ESlct None 02 02 -- C077 Communication error time-out COM ETIM 000. 00s C078 Communication wait time COM Wait 00000ms 0. 00 0. 00 sec. 0. 0. msec. L2002 Inverter 3­59 Analog Signal Calibration Settings The functions in the following table configure the signals for the analog output terminals. Note that these settings do not change the current/voltage or sink/source characteristics--only the zero and span (scaling) of the signals. "C" Function Func. Code Name / SRW Display Description Run Defaults Mode Edit ­FE(F) ­FU Units Lo Hi (EU) (USA) 100. 0 100. 0 % C081 O input span calibration Scale factor between the external frequency command O-ADJ 0100. 0% on terminals L ­ O (voltage input) and the frequency output, range is 0. 0 to 200. 0% C082 OI input span calibration OI-ADJ 0100. 0% Scale factor between the external frequency command on terminals L ­ OI (current input) and the frequency output, range is 0. 0 to 200. 0% 100. 0 100. 0 % C085 Thermistor input tuning Range is 0. 0 to 200. 0% PTC Adj 0100. 0% Range is 0. 0 to 10. 0V 100. 0 100. 0 % Configuring Drive Parameters C086 [AM] terminal offset tuning AM-OFFST 0000. 0V 0. 0 0. 0 V NOTE: When you restore factory default settings, the values will change to those listed above. Be sure to manually reconfigure the values for your application, if needed, after restoring factory defaults. 3­60 "C" Group: Intelligent Terminal Functions Miscellaneous Functions The following table contains miscellaneous functions not in other function groups. "C" Function Func. Code Name / SRW Display Description Displays debug parameters. Enable Controls speed setpoint for the inverter after power cycle. Clear last frequency (return to default frequency F001) 01. . . Keep last frequency adjusted by UP/DWN Determines response to Reset input [RST]. Cancel trip state at input signal ON transition, stops inverter if in Run Mode 01. . . Cancel trip state at signal OFF transition, stops inverter if in Run Mode 02. . . Cancel trip state at input signal ON transition, no effect if in Run Mode Run Defaults Mode Edit ­FE(F) ­FU Units Lo Hi (EU) (USA) 00 00 -- C091 Debug mode enable DBG Slct OFF C101 Up/Down memory mode selection UP/DWN NO-STR 00 00 -- C102 Reset selection RS Slct ON 00 00 -- Configuring Drive Parameters L2002 Inverter 3­61 Output Logic and Timing Logic Output Function ­ The inverter has a built-in logic output feature. You can select any two of the other nine intelligent output options for internal inputs. Then, configure the logic function to apply the logical AND, OR, or XOR (exclusive OR) operator as desired to the two inputs. [. . . ] If two cables intersect (one crosses over the other), the interference is smallest if they intersect at an angle of 90°. Cables susceptible to interference should therefore only intersect motor cables, intermediate circuit cables, or the wiring of a rheostat at right angles and never be laid parallel to them over longer distances. Minimize the distance between an interference source and an interference sink (interference-threatened device), thereby decreasing the effect of the emitted interference on the interference sink. · You should use only interference-free devices and maintain a minimum distance of 0. 25 m from the adjustable frequency inverter. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HITACHI L200-2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HITACHI L200-2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag