User manual HONEYWELL AV DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL AV. We hope that this HONEYWELL AV user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL AV.


Mode d'emploi HONEYWELL AV
Download
Manual abstract: user guide HONEYWELL AVDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] 20 I Solenoid valves as anti-siphon valve according to DIN EN264 AV s e r i e s DN 10­40 This range of high-quality solenoid valves is not dependent on a specific minimum differential pressure; the valves operate extremely reliably with no pressure, at slight differential pressure, right through to maximum pressure. [. . . ] 5S235/2000) and are particularly suitable for use as anti-siphon valves in supply installations for light fuel oil EL. Dimensioned drawings Technical data Type Operating mode Type of construction Pressure range Materials Sealing material Mounting position Temperature of medium Max. ambient temperature Duty cycle Electrical connection Voltage / current type Special voltages available Degree of protection Power consumption in VA or W 2/2-way normally closed Diaphragm solenoid valve, coupled. -0. 9 to 4 bar (DN 10, 13), -0. 9 to 10 bar (DN 20-40) No back-pressure may occur as the valve will open in an uncontrolled manner. Casing: brass, internal parts: stainless steel FPM (Viton) Any, solenoid system preferably upright 0°C to +90°C 55°C 100% ED Device socket to DIN 43 650 Standard version 230 V, 50 Hz Voltage Code 110 VAC 2 24 VAC 8 24 VDC 6 IP 65 according to DIN 40 050 with device socket Switching Nominal diameter/DN state 10 13 20 25 40 mm AC: Start 34 36 38 160 202 VA AC: Oper. [. . . ] 14 14 14 38 38 VA DC: Start + Operation 10 10 10 ­ ­ W Product Summary DN (mm) 10 13 20 25 25 40 40 DN 10 13 20 25 25 40 40 A 72 83 99 145 145 157 157 Pressure range (bar) -0. 9 -0. 9 -0. 9 -0. 9 -0. 9 -0. 9 -0. 9 ­ ­ ­ ­ ­ ­ ­ B 86 99 119 166 166 187 187 4 4 10 10 10 10 10 C 38 45 66 105 105 105 105 kvs value (m3/h) 1. 8 3. 5 8. 6 11. 0 11. 0 30. 0 30. 0 D 38 51 66 105 105 105 105 E 20 24 35 69 69 69 69 Connection thread G 3/8" G 1/2" G 3/4" G 1" G 1 1/4" G 1 1/2" G 2" F 12 14 16 18 18 22 22 G G 3/8" G 1/2" G 3/4" G 1" G 1 1/4" G 1 1/2" G 2" Weight (kg) 0. 4 0. 55 1. 0 1. 7 1. 7 3. 5 3. 5 K 65 65 65 69 69 69 69 L 50 58 80 95 95 132 132 Type Shown without plug connector AV102MS2 AV131MS2 AV201MS2 AV251MS2 AV252MS2 AV401MS2 AV402MS2 M 3. 5 3. 5 3. 5 7 7 7 7 SW 27 32 41 41 50 60 70 s Degree of protection: IP 65 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL AV

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL AV will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag