User manual HONEYWELL CHORONOTHERM IV INSTALLATION GUIDE, CHRONOTHERM 4 INSTALLATION GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL CHORONOTHERM IV INSTALLATION GUIDE, CHRONOTHERM 4 INSTALLATION GUIDE. We hope that this HONEYWELL CHORONOTHERM IV INSTALLATION GUIDE, CHRONOTHERM 4 INSTALLATION GUIDE user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL CHORONOTHERM IV INSTALLATION GUIDE, CHRONOTHERM 4 INSTALLATION GUIDE.


Mode d'emploi HONEYWELL CHORONOTHERM IV INSTALLATION GUIDE, CHRONOTHERM 4 INSTALLATION GUIDE
Download
Manual abstract: user guide HONEYWELL CHORONOTHERM IV INSTALLATION GUIDE, CHRONOTHERM 4 INSTALLATION GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] T8602D Chronotherm® IV Programmable Thermostats INSTALLATION INSTRUCTIONS APPLICATION The T8602 Chronotherm® IV Programmable Thermostat provides electronic control of 24 Vac single-stage heating and cooling systems or 750 mV heating and 750 mV cooling. Refer to Table 1 for a general description of the thermostat. All T8602 Thermostats are powered by batteries. Table 1. T8602 D System Heat-Cool Changeover Manual or Automatic Selectable System Selection Heat-Off-Cool or Heat-Off-Cool-Auto Fan Selection On-Auto Comments System and fan selections are done by keyboard. If this control is replacing a control that contains mercury in a sealed tube, do not place your old control in the trash. [. . . ] — To enter the installer setup, press and hold the information i key with the increase and decrease keys until the first number is displayed. All display segments appear for approximately three seconds before the number is displayed. — To advance to the next Installer Setup, press the Time ∆ key. — To change a setting, use the increase or decrease key. — To scroll the Installer Setup numbers backward, press the Time ∇ key. — To exit the Installer Setup, press Run Program. INSTALLER SETUP NUMBER DISPLAY (COLUMN 2 OF TABLE 3) FACTORY SETTING OR OTHER CHOICE DISPLAY (COLUMN 3 OR 5 OF TABLE 3) M14618 Fig. Display of Installer Setup number and setting. CAUTION Electric Heat Configuration Hazard. Configure electric heat system to 1 in Installer Setup number 2 to prevent system running without fan. IMPORTANT Only configured numbers are shown on the device. Example: If thermostat does not have a System key, Installer Setup Number 12 will not be displayed. Review Table 3 factory settings and mark any desired changes in the Actual Setting column. When Installer Setup is complete, review the settings to confirm that they match the system. 5 69-1510-4 T8602D CHRONOTHERM® IV PROGRAMMABLE THERMOSTATS Table 3. Installer Setup Number (Press Time ∆ key to change) 1 2 (Number 2 must be set to 1 to extend fan operation. ) Factory Setting Display — 0 Description — Conventional applications where equipment controls fan operation in heat mode. — 6—6 cph used for conventional heat. (Press Display — 1 Other Choices or key to change) Description — Heat pump or electric heat applications where thermostat controls fan operation in heat mode. Actual Setting — Select Not Used. Heating cycle rate. 3 4 — 6 — 1, 3, or 9 — 1—1 cph used for radiant floor heat, gravity system. 3—3 cph used for hot water systems or high efficiency furnaces. 9—9 cph used for electric heat systems. — 0—Auto changeover 2—Auto only Adaptive Intelligent Recovery™ control is activated (system starts early so setpoint is reached by start of program period). — Not Used. System setting adjustment Adaptive Intelligent Recovery™ control. 5 thru 11 12 — 1 — Manual changeover Conventional recovery (system starts recovery at programmed time). — No outdoor temperature is displayed. — 0 or 2 — 13 1 — Not Used. Outdoor temperature display (select models). [. . . ] Set heating setpoint to desired temperature. • Check for 24 Vac between R or RC and Y terminals — If missing 24 Vac: — check if the circuit breaker is tripped—reset the circuit breaker. — check if the system fuse is blown—replace the fuse. — check if the power switch on the HVAC equipment is in the Off position—set to the On position. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL CHORONOTHERM IV INSTALLATION GUIDE, CHRONOTHERM 4 INSTALLATION GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL CHORONOTHERM IV INSTALLATION GUIDE, CHRONOTHERM 4 INSTALLATION GUIDE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag