User manual HONEYWELL CM900 WIRELESS INSTALLATION

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL CM900 WIRELESS. We hope that this HONEYWELL CM900 WIRELESS user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL CM900 WIRELESS.


Mode d'emploi HONEYWELL CM900 WIRELESS
Download
Manual abstract: user guide HONEYWELL CM900 WIRELESSINSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] DRAWING DETAILS PART NUMBER ISS ECO AND DATE 42011076-003 R2 0024168 08/06 DRAWN MKTING DATE ARTWORK DESCRIPTION CM900 RF INSTALLATION GUIDE (UK - English) MF BM 08/06 SIZE AND FOLDING A3 SIZE WHEN PRINTED SIZE WHEN FOLDED A4 A5 x A6 x A7 OTHER BOOKLET MATERIAL CARTRIDGE MATT ART x WEIGHT 70g x 80g 100g 115g 150g OTHER PRINTING SINGLE SIDE DOUBLE SIDE ONECOLOUR TWOCOLOUR THREECOLOUR FULLCOLOUR x x BLACK SEE FOLLOWING PAGES FOR COLOUR DESIGNATION. ALL PRINTING MUST BE CLEAR, FREE OF SMUDGES AND MULTI COLOUR PRINT PROPERLY REGISTERED SPECIAL INSTRUCTIONS Folding Sequence Finished Size 148mm 105mm CM900 RF Installation Guide xxxxxxxxxx Part Number Front 12 page A5 saddle stitched booklet folded to A6 Back DO NOT INCLUDE THIS PAGE IN THE PRINTING CM900 Wireless Installation Guide CM927 / CM921 Wireless Programmable Room Thermostat & HC60NG Receiver Box Description The Honeywell CM900 Wireless (CM927 or CM921) is a modern wireless programmable room thermostat based on Honeywell's proven programming philosophy. To further improve the ease of use, this product includes an extra large LCD display with backlighting and LoT Technology to assist customers during daily use. The CM927/921 room thermostat communicates with the HC60NG receiver box on an 868MHz Radio Frequency (RF) band to control a single heating system component such as a boiler, pump or zone valve. [. . . ] · It is recommended that the receiver box is fully installed. 2. 3 System Check Now a simple test can be completed to check the full system has been installed correctly: 1. Check the boiler supply is on and check that the green LED on the receiver box is off. Adjust the setpoint up to the maximum (35°C) by pressing the button. The boiler should come on (green LED ON on receiver box) after a few seconds and the symbol appears on the room thermostat LCD display. The boiler will go off (green LED OFF on receiver box) after a few seconds and the symbol disappears. Check the system operation by moving the slider between MAN and OFF modes several times, bearing in mind the switching delay referred to above. Now, you should have completed the installation successfully - to begin operating at the default factory settings move the slider to the AuTO mode or select PROG to modify the built-in heating program accordingly. Installation Guide 3) Basic Operation of the System 3. 1 Automatic Operation The receiver box receives the heat demand (0100%) signal from the room thermostat. The room thermostat will display the symbol on the LCD display whenever more heat is required. Depending on the demand the receiver box will switch the heating device on to match the current requirements of the system. The green LED indicates the status of the relay output: · Green LED on = relay on · Green LED off = relay off HC60NG Receiver Box Push button and relay status LED's 3. 2 Temporary Manual Override Pressing the receiver box button will override the current relay position. As soon as the next signal is received from the room thermostat the receiver box will return back to automatic operation as the automatic control has higher priority than manual operation. 3. 3 Communications Loss If the RF communication is lost for a period of 1 hour the red LED will illuminate to indicate that no RF messages have been received during the last hour. The receiver box will also enter the failsafe mode as selected in Installer Mode (see section 4. 2 HC60 Receiver Box Fail-Safe Mode Setup). To allow manual control of the receiver box output manual override is available in fail-safe mode. When RF communication is restored the receiver box will automatically return to normal operation. You can now use the USER GUIDE supplied with the room thermostat to demonstrate how it works to the home owner. 4) Installer Mode Installer Mode is used to alter the system settings for specific applications, to use the special features of the room thermostat in a different way or to alter the factory preset parameters. Parameters are divided into two groups: - Category 1 parameters ­ Room Thermostat Setup - Category 2 parameters ­ System Setup. These are all listed in section 4. 5 Installer Parameters Table. CM900 Wireless - Programmable Room Thermostat 4. 1 Entering Installer Mode 1 DAY COPY DAY 2 OFF DATE PROG AUTO MAN OFF CM9 1. . Move the slider switch to the OFF mode. button and the two & The unit will display the first parameter of installer parameter group category 1 (from Parameter n. 1 to n. 19) as shown 3 Press the or to change factory setting. The display will flash indicating that a change has been made. 4 Press the green button to confirm the change. The display will stop flashing. 5 Press button to go to the next parameter. 6 Press button to go to Installer parameter group category 2 ( ) (from Parameter n. 1 to n. 14). 7 To exit the installer mode, move the slider switch to the AuTO or MAN positions. 4. 2 HC60NG Receiver Box Fail-Safe Mode Setup The failsafe mode defines the receiver box output relay status if the RF communication is lost (e. g. when the room thermostat stops communicating due to discharged batteries). [. . . ] If the red LED still flashes push the button again until binding is successful. Now go to Section 2) Installing the CM900 Wireless System to setup the system. 5. 2 Multi-Zone System Multiple room thermostats and receiver box sets can also be used to control multi-zone systems and the CM927/921 room thermostat is compatible with a variety of other Honeywell products including HR80 radiator controllers and HCE80 underfloor heating controllers. If you intend to use it in this way additional installation and user instructions can be obtain by contacting the address at the end of this guide. NOTE: Some of the labels supplied with the pack are for use in multizone applications. Installation Guide 11 6) Trouble Shooting 6. 1 Trouble Shooting Guide Symptom (Fault Message) The room thermostat displays the symbol but the receiver box relay does not switch on. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL CM900 WIRELESS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL CM900 WIRELESS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag