User manual HONEYWELL D06F

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL D06F. We hope that this HONEYWELL D06F user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL D06F.


Mode d'emploi HONEYWELL D06F
Download

You may also download the following manuals related to this product:

   HONEYWELL D06F SPECIFICATION (292 ko)

Manual abstract: user guide HONEYWELL D06F

Detailed instructions for use are in the User's Guide.

[. . . ] Use the appliance according to its intended use in good condition with due regard to safety and risk of danger. Note that the appliance is exclusively for use in the applications detailed in these installation instructions. Any other use will not be considered to comply with requirements and would invalidate the warranty. [. . . ] 25 bar with brass or stainless steel filter bowl Outlet pressure 1. In applications where UV radiation and solvent vapours are present, use the SM06T brass filter bowl!The device downstream should be protected by means of a safety valve (installed downstream of the pressure reducing valve). ⷠThe installation location should be protected against frost and be easily accessible o Pressure gauge can be read off easily o With clear filter bowl, degree of contamination can be easily seen o Simplified maintenance and cleaning · For residential applications where maximum protection against dirt is required, install a fine filter upstream of the pressure reducing valve · Provide a straight section of pipework of at least five times the nominal valve size after the pressure reducing valve (in accordance with DIN 1988, Part 5) Operating temperature Maximum 40°C with clear filter bowl Maximum 70°C with brass or stainless steel filter bowl Minimum pressure 1. Install pressure reducing valve o Note flow direction o Install without tension or bending stresses As part of an installation being approved according to PED requirements, this product must also be certified. Frequency: every 1-3 years (depending on local operating conditions) To be carried out by an installation company Close shutoff valve on inlet Release pressure on outlet side (e. Through water tap) Close shutoff valve on outlet Loosen slotted screw o Do not remove slotted screw Caution !Slacken tension in compression spring o Turn control handle to the left (-) until it does not move any more 6. Remove valve insert with a pair of pliers 9. Check that sealing ring, edge of nozzle and slotted ring are in good condition, and if necessary replace the entire valve insert 12. Reassemble in reverse order Press in diaphragm with finger before inserting slip ring Screw in filter cup hand-tight (without tools) 15. Close shutoff valve on inlet Release pressure on outlet side (e. Through water tap) Close shutoff valve on outlet Loosen slotted screw o Do not remove slotted screw Slacken tension in compression spring o Turn control handle to the left (-) until it does not move any more Slowly open shutoff valve on inlet Turn control handle until the setting scale shows the desired value Retighten slotted screw Slowly open shutoff valve on outlet We recommend a planned maintenance contract with an installation company In accordance with DIN 1988, part 8, the following measures must be taken: Frequency: once annually To be carried out by an installation company or the operator. Check back pressure using a pressure meter when there is zero through-flow o If the pressure is increasing slowly, the valve may be dirty or defective. In this instance, carry out servicing and cleaning 3. A new setting can be achieved using a pressure gauge. [. . . ] 1 Spring bonnet complete 1/2" + 3/4" with setting scale 1" + 11/4" D06F, D06FI 11/2" + 2" Spring bonnet complete 1/2" + 3/4" 1" + 11/4" with setting scale 11/2" + 2" D06FH, D06F-1/4ZA Spring bonnet complete 1/2" + 3/4" 1" + 11/4" with setting scale 11/2" + 2" D06FN 2 Valve insert complete D06F, D06FH (without filter) Valve insert complete D06FN (without filter) Valve insert complete D06FI (without filter) HABEDO ® Retrofit filter Reverse-rinsing filter for retro-conversion to a filter combination unit of pressure reducing valves M07M Pressure gauge Housing diameter 63 mm, rear connection thread G1/4". ranges: 0 - 4 , 0 - 10 , 0 - 16 or 0 - 25 bar. Please indicate upper value of pressure range when ordering ZR06K Double ring wrench For removal of spring bonnet and filter bowl RV277 Inlet check valve Available in sizes R1/2" - 2" VST06-A Connection set Threaded connections VST06-B Connection set Solder connections VST06I-A Connection set With stainless steel threaded connections ) 7 Clear filter bowl with O-ring D06F, D06FI Brass filter bowl with O-ring D06F, D06FH, D06FN [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL D06F

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL D06F will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag