User manual HONEYWELL D100 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL D100. We hope that this HONEYWELL D100 user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL D100.


Mode d'emploi HONEYWELL D100
Download
Manual abstract: user guide HONEYWELL D100DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Please refer to the technical specifications of the individual controllers in order to determine their suitability for use in conjunction with a given wall module application. · The C7110C1001 is equipped with a CO2 sensor. The C7110D1009 is equipped with both a CO2 sensor and a space temperature sensor. The C7110D1009 also features a setpoint adjustment dial. By default, the "Celsius Relative" type (-5 to +5) is mounted, but can be easily replaced with the "Celsius Absolute" type (12 to 30°C). [. . . ] 1). 80 K C7110D Setpoint Adjustment: In the case of the C7110D, which is equipped with a setpoint adjustment dial, depending on the type of dial in use, the corresponding controller must be set for either the relative or the absolute scale. The relation between setpoint and resistance is given in Table 3. Accuracy of resistance is: · ±5% in middle position, e. g. 5225 to 5775 · ±10% in end position, e. g. Setpoint values versus resistances relative scale (Kelvin) absolute scale (°C) nominal nominal setpoint setpoint resistance () resistance () -5 9574. 0 12 9958. 0 -4 8759. 2 13 9468. 7 -3 7944. 4 14 8979. 3 -2 7129. 6 15 8490. 0 -1 6314. 8 16 8000. 7 0 5500. 0 17 7511. 3 1 4685. 2 18 7022. 0 2 3870. 4 19 6532. 7 3 3055. 6 20 6043. 3 4 2240. 8 21 5554. 0 5 1426. 0 22 5064. 7 23 4575. 3 24 4086. 0 25 3596. 7 26 3107. 3 27 2618. 0 28 2128. 7 29 1639. 3 30 1150. 0 electrical resistance (ohms) 70 K 60 K 50 K 40 K 30 K 20 K 10 K 30 0 40 50 10 60 70 20 80 90 100 110 ° F 30 40 °C temperature (degrees) Fig. resistance for 20 k sensor Honeywell controllers used with these Wall Modules employ an algorithm that provides readings close to the actual temperature. Table 2 summarizes the sensor accuracy for normal operating temperatures. EN0B-0457GE51 R0309 2 C7110C, D WALL MODULES Configuration of Pin 2 The CO2 output (pin 2) of the C7110C/D Wall Modules can be configured (using the UIP software module ­ see also section "UIP Software Module" on page 4). In order to use the UIP software module to reconfigure pin 2, you must first connect the Wall Module's four-prong male connector (located to the right of the terminal block on the PCB after removing the cover; see Fig. 2) to one of your PC's serial communication ports; this is done using the HDI 10 Interface Cable, available as an accessory (see section "HDI 10 Interface Cable" on page 4). NOTE: After having selected "Scaled Output, " the CO2 level LED of the C7110C is disabled. Relay Output (Digital Output) If you select the "Relay Output" checkbox, pin 2 will deliver digital output. In this case, you can then configure a "Threshold Level (PPM)" of any value between 0 and 2000 ("600" is the default setting), and a "Hysteresis (PPM)" of any value between 1 ppm and 50% of the "Threshold Level (PPM)" ("100" is the default setting). 4 for the resultant output of pin 2 and (in the case of the C7110C) the corresponding behavior of the CO2 level LED. output THRESHOLD LEVEL (ppm) (GREEN TO YELLOW) 10 V Fig. Four-prong male connector Upon then starting the UIP software program (only one instance of which may be active on your PC at a time), a window will appear in which you must specify to which of your PC's serial communication port you have connected the fourprong male connector. Following this, a second window (the "configuration window") will appear in which you can configure pin 2 in a variety of fashions (see following sub-sections). NOTE: If your PC is not equipped with a mouse or track ball, you can navigate forwards by pressing your PC's TAB key, and backwards by pressing SHIFT + TAB. Further, you can check/uncheck selections using the SPACE key 0V 500 600 CO2 (ppm) Fig. Relay output (digital) of pin 2 In the case of the C7110C, the resultant output is applied to the LED input (pin 6). The CO2 level LED will thus glow green below and yellow above the threshold level. Occupancy Bypass Button / Occupancy LED (C7110D1009, only) Overrides can result e. g. from the controller's own internal programming. In the case of the C7110D1009, overrides can also result from pressing the occupancy bypass button (see also Fig. [. . . ] cable lengths set forth by the LONWORKS Guidelines, to the LONWORKS network via a LONWORKS bus cable). Via an additional 3. 5 mm jack plug on the board, a PC connection can be established. Order quantity: set of 5 pieces T7460-LIMITER Order quantity: Operating Temperature: 43. . . 104°F (6. . . 40°C). Shipping Temperature: -40. . . +150°F (-40. . . +65°C). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL D100

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL D100 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag